C2 · Lesson 11 · Decoupling and hold-up
Capacitors as local energy stores
A processor's current jumps by amps within nanoseconds, far faster than its power supply, a few centimeters of copper away, can respond: the wiring's inductance won't let the current change that quickly. The capacitors scattered around the chip supply the charge in the meantime. On a larger scale, a power supply that keeps running for a few milliseconds after the plug is pulled, or a memory that saves its data when power fails, is living off a capacitor's stored energy. Both designs come down to how much charge, or energy, a capacitor can give up before its voltage falls too far.
- A capacitor charged to powers a load after its supply disappears. The solid curve is a constant-power load, like a switching converter; the dashed one draws a constant current equal to the starting current.
- The constant-power load drains faster and faster: as the voltage falls, it draws more current to keep its power.
- The readout gives how long the constant-power load runs before the voltage reaches .
Predict
A 470 µF capacitor at 12 V feeds a 5 W converter that keeps working down to 9 V. About how long does it hold up?
About 3 ms. The usable energy is mJ, and at 5 W that lasts 2.96 ms. Below 9 V the converter stops, so the energy left in the capacitor, more than half of it, can't be used.
Name it
Supplying fast current
A chip draws an extra current for a time before anything farther away can respond. A local capacitor supplies the charge and droops by
so the capacitor needed for a droop budget is . Power-integrity engineers phrase the same thing as a target impedance: the supply network must stay below at every frequency the chip's current contains, which takes capacitors of several sizes (lesson 4) placed close to the chip.
Holding up a load
When the supply disappears, a capacitor feeding a load falls:
- Constant current : linearly, .
- Constant power , as a switching regulator draws: from the energy, , so
Only the fraction of the stored energy is usable above , which is why hold-up capacitors are charged to as high a voltage as practical.
Inrush
Charging a large capacitor from a supply through resistance draws a peak current at the first instant and dissipates in the resistance, the same as the capacitor stores (lesson 10). Big capacitor banks charge through a resistor or a current limit, then bypass it.
Worked example
A chip pulls an extra 0.5 A for 20 ns before the regulator can respond. How much does a local 1 µF capacitor droop?
Show the solution
- Droop from the charge drawn.
- In practice. Its ESL and ESR (lesson 4) add to that, which is why several capacitors share the job.
Answer it droops about 10 mV, plus what its ESL and ESR add.
Worked example
A 1 F supercapacitor at 5 V backs up a 2 W load that works down to 3 V. How long does it last?
Show the solution
- Hold-up time.
- Energy used. That uses 64% of the stored 12.5 J.
Answer it lasts 4 s, using 64% of its stored 12.5 J.
Worked example
A load steps by 3 A, and the regulator takes 10 µs to respond. How much bulk capacitance keeps the droop under 50 mV, and how small must its ESR be?
Show the solution
- Capacitance. Until the regulator responds, the capacitor supplies the step, with , so
- ESR. The current also flows through the capacitor's ESR at once, dropping , so the ESR must be well under really less, since both drops add.
- In practice. Several capacitors in parallel are usually the answer: their capacitances add and their ESRs divide.
Answer at least 600 µF of bulk capacitance, with an ESR well under 17 mΩ.
Check
A 10 µF capacitor supplies an extra 1 A for 5 ns. How much does it droop?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A load step of 0.5 A must be held for 10 ns with no more than 30 mV of droop. What capacitance does that take?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A chip's supply may move by 30 mV when its current changes by 1 A. What is the target impedance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A 100 µF capacitor at 12 V feeds a 10 W constant-power load that works down to 10 V. How long does it hold up?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A capacitor discharged from 12 V to 6 V gives up what percentage of its stored energy?
Check
A discharged capacitor is connected to 48 V through 0.1 Ω. What is the peak inrush current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A load steps by 3 A, and the regulator takes 2 µs to respond. The droop must stay under 100 mV.
(a)
How much capacitance does that need, ignoring ESR?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
What's the most ESR the capacitors could have even with infinite capacitance?
Check
A step I is supplied for time t by a capacitor C with ESR R.
Step 1
What's the droop from discharge?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's the immediate drop across the ESR?
Step 3
What's the total droop, roughly?
Explain why
Why does a constant-power load drain a capacitor faster and faster as it discharges?
A constant-power load, such as a switching regulator, adjusts its current to keep its output power the same. As the capacitor's voltage falls, the same power needs more current, , and more current pulls the voltage down faster still. A resistive or constant-current load does the opposite or stays steady. Counted in energy, the capacitor gives up energy at a constant rate, so its stored energy, which goes as , falls linearly while the voltage drops ever more steeply.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.