C2 · Lesson 17 · Designing a second-order response
Overshoot, peak time and settling, and choosing R to meet them
Engineers rarely ask "is it underdamped?" They ask "how much does it overshoot, and how soon does it settle?" A power supply's output may overshoot by no more than a few percent when the load changes; a measurement must settle within a microsecond; a servo should get where it's going quickly without ringing. For a second-order circuit, all of these follow from the damping ratio and the resonant frequency, so a specification can be turned straight into component values.
- A 5 V step drives a series RLC (L = 10 mH, C = 100 nF). Adjust R and watch the overshoot, the time of the first peak and how long it rings.
- At about 374 Ω the overshoot is 10%. At 632 Ω it's critically damped: no overshoot, and the quickest settling without one.
- Well above that, it's overdamped and creeps up slowly.
Predict
A step response must overshoot by no more than 5%. What damping ratio does that need, roughly?
About 0.69. Overshoot falls steeply with damping: ζ = 0.3 overshoots 37%, ζ = 0.5 overshoots 16%, ζ = 0.7 about 5%, and ζ = 1 not at all. Many designs aim for ζ near 0.7 as a balance of speed and overshoot.
Name it
The measures
For an underdamped second-order step response with damping ratio ζ and resonant frequency (lessons 15 and 16), with :
| Measure | Formula |
|---|---|
| overshoot (fraction) | |
| peak time | |
| 2% settling time | |
| quality factor |
Working backward
From a required overshoot :
Then the component values follow from ζ. For a series RLC, ; for a parallel one, . If the settling time is also specified, it fixes and so .
Trade-offs
Lower damping gives a faster first rise but more overshoot and longer ringing; higher damping removes the overshoot but, past critical damping, slows the approach. Critical damping (ζ = 1) is the fastest response with no overshoot at all, which is why meters, door closers and car suspensions aim near it.
Worked example
Choose R for a series RLC with L = 10 mH and C = 100 nF to overshoot 10%.
Show the solution
- Damping ratio for 10% overshoot. With and ,
- Characteristic resistance.
- Resistance.
Answer R = 374 Ω gives 10% overshoot.
Worked example
For that design, when does the first peak come, and how long does it take to settle within 2%?
Show the solution
- Ringing frequency. With rad/s,
- First peak.
- Settling time.
Answer the first peak comes at 123 µs, and the response settles within 2% after about 214 µs.
Worked example
A series RLC has L = 1 mH and R = 100 Ω. What capacitance gives ζ = 0.707, and how much does its step response overshoot?
Show the solution
- Solve for C. For a series RLC, , so
- Overshoot.
- Why 0.707. Damping ratio 0.707 is a common target: the fastest rise with modest overshoot, and in the frequency domain the flattest response with no peak, the Butterworth response C4 builds on.
Answer 200 nF gives ζ = 0.707, and the step response overshoots by 4.3%.
Check
A second-order system has ζ = 0.4. By what percentage does its step response overshoot?
Check
What damping ratio gives 5% overshoot?
Check
What series resistance gives ζ = 0.5 with L = 1 mH and C = 100 nF?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A system with ζ = 0.3 and a resonant frequency of 1 kHz takes a step. When is its first peak?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
About how long does a system with ζ = 0.5 and = 1 kHz take to settle within 2%?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
What is the quality factor of a system with ζ = 0.1?
Check
Choose so the 5 V step overshoots by 10%: a peak of 5.5 V.
Type values the way you would write them on a schematic: 4.7k, 100n, 10m. Then try them: the circuit runs with your values and is measured.
Check
Choose so the output never overshoots by more than 1% and is within 1% of 5 V by 0.5 ms.
Type values the way you would write them on a schematic: 4.7k, 100n, 10m. Then try them: the circuit runs with your values and is measured.
Check
A series RLC has L = 1 mH and R = 50 Ω, and should have ζ = 0.707.
(a)
What capacitance does that need?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
(b)
How much will its step response overshoot?
Check
A second-order system with damping z and natural frequency w (rad/s).
Step 1
What fraction does it overshoot?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
At what frequency does it ring?
Step 3
When is the first peak?
Explain why
Why do so many designs aim for a damping ratio near 0.7 rather than 1?
A critically damped system (ζ = 1) never overshoots, but it approaches its final value rather slowly near the end. Reducing ζ to about 0.7 makes the response rise noticeably faster, at the cost of only about 5% overshoot, and it settles within a few percent in less time than the critically damped one does. For many uses a small, brief overshoot is a fair price for speed. Where any overshoot is unacceptable, as when it could damage a part or trip a limit, designers move toward ζ = 1.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.