C217 of 30
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C2 · Lesson 17 · Designing a second-order response

Overshoot, peak time and settling, and choosing R to meet them

Engineers rarely ask "is it underdamped?" They ask "how much does it overshoot, and how soon does it settle?" A power supply's output may overshoot by no more than a few percent when the load changes; a measurement must settle within a microsecond; a servo should get where it's going quickly without ringing. For a second-order circuit, all of these follow from the damping ratio and the resonant frequency, so a specification can be turned straight into component values.

  • A 5 V step drives a series RLC (L = 10 mH, C = 100 nF). Adjust R and watch the overshoot, the time of the first peak and how long it rings.
  • At about 374 Ω the overshoot is 10%. At 632 Ω it's critically damped: no overshoot, and the quickest settling without one.
  • Well above that, it's overdamped and creeps up slowly.

Predict

A step response must overshoot by no more than 5%. What damping ratio does that need, roughly?

Name it

The measures

For an underdamped second-order step response with damping ratio ζ and resonant frequency ω0 (lessons 15 and 16), with ωd=ω01−ζ2:

MeasureFormula
overshoot (fraction)Mp=e−ζπ/1−ζ2
peak timetp=π/ωd
2% settling timets≈4ζω0
quality factorQ=12ζ

Working backward

From a required overshoot Mp:

ζ=−ln⁡Mpπ2+ln2⁡Mp

Then the component values follow from ζ. For a series RLC, R=2ζL/C; for a parallel one, R=12ζL/C. If the settling time is also specified, it fixes ω0 and so LC.

Trade-offs

Lower damping gives a faster first rise but more overshoot and longer ringing; higher damping removes the overshoot but, past critical damping, slows the approach. Critical damping (ζ = 1) is the fastest response with no overshoot at all, which is why meters, door closers and car suspensions aim near it.

Worked example

Choose R for a series RLC with L = 10 mH and C = 100 nF to overshoot 10%.

Show the solution
  1. Damping ratio for 10% overshoot. With ln⁡0.1=−2.303 and π2=9.870, ζ=2.3039.870+5.302=0.591
  2. Characteristic resistance. L/C=316Ω
  3. Resistance. R=2×0.591×316Ω=374Ω

Answer R = 374 Ω gives 10% overshoot.

Worked example

For that design, when does the first peak come, and how long does it take to settle within 2%?

Show the solution
  1. Ringing frequency. With ω0=31,600 rad/s, ωd=31,6001−0.349=25,500rad/s
  2. First peak. tp=π25,500s=123μs
  3. Settling time. ts≈40.591×31,600s=214μs

Answer the first peak comes at 123 µs, and the response settles within 2% after about 214 µs.

Worked example

A series RLC has L = 1 mH and R = 100 Ω. What capacitance gives ζ = 0.707, and how much does its step response overshoot?

Show the solution
  1. Solve for C. For a series RLC, ζ=R2CL, so C=4ζ2LR2=4×0.5×10−3104F=200nF
  2. Overshoot. e−πζ/1−ζ2=4.3%
  3. Why 0.707. Damping ratio 0.707 is a common target: the fastest rise with modest overshoot, and in the frequency domain the flattest response with no peak, the Butterworth response C4 builds on.

Answer 200 nF gives ζ = 0.707, and the step response overshoots by 4.3%.

Check

A second-order system has ζ = 0.4. By what percentage does its step response overshoot?

Check

What damping ratio gives 5% overshoot?

Check

What series resistance gives ζ = 0.5 with L = 1 mH and C = 100 nF?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

A system with ζ = 0.3 and a resonant frequency of 1 kHz takes a step. When is its first peak?

Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.

Check

About how long does a system with ζ = 0.5 and f0 = 1 kHz take to settle within 2%?

Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.

Check

What is the quality factor of a system with ζ = 0.1?

Check

Choose R1 so the 5 V step overshoots by 10%: a peak of 5.5 V.

Type values the way you would write them on a schematic: 4.7k, 100n, 10m. Then try them: the circuit runs with your values and is measured.

Check

Choose R1 so the output never overshoots by more than 1% and is within 1% of 5 V by 0.5 ms.

Type values the way you would write them on a schematic: 4.7k, 100n, 10m. Then try them: the circuit runs with your values and is measured.

Check

A series RLC has L = 1 mH and R = 50 Ω, and should have ζ = 0.707.

(a)

What capacitance does that need?

Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.

(b)

How much will its step response overshoot?

Check

A second-order system with damping z and natural frequency w (rad/s).

Step 1

What fraction does it overshoot?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why do so many designs aim for a damping ratio near 0.7 rather than 1?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.