C2 · Lesson 23 · Measuring C and L
Timing, resonance and impedance methods
A multimeter reads resistance directly, but capacitance and inductance only show themselves when something changes: a voltage rising, a current ramping, a circuit ringing. Every way of measuring them uses one of those changes. A microcontroller times how long a touch pad takes to charge; a lab LCR meter applies a small sine wave and measures the current's size and phase; a technician pulses an inductor and watches its current ramp to see where it saturates. Each method is a direct use of , or resonance.
- A capacitor charges through a known resistor toward 5 V. Two thresholds, set by the markers, are crossed at times and .
- Timing between two thresholds is more robust than timing from zero: it doesn't need to know exactly when charging started.
- The readout turns the measured times back into C. Change the true C and see the measurement track it.
Predict
A capacitor charging through 10 kΩ toward 5 V takes 1.39 ms to go from 1 V to 4 V. What is its capacitance?
About 100 nF. Between thresholds, , so τ = 1.0 ms and nF.
Name it
Timing methods
Charge through a known toward and time the crossing of two thresholds:
Microcontroller touch sensors do this: a finger adds a few picofarads and the charge time grows. For an inductor, apply a voltage and watch the current ramp: . Where the ramp suddenly steepens, the core is saturating (lesson 5).
Resonance
Put an unknown with a known (or the reverse), ring it, and measure the frequency:
Impedance (LCR meters)
An LCR meter applies a small sine wave at a known frequency, measures the current's magnitude and phase, and computes the complex impedance. The reactive part gives the value, or ; the resistive part gives the ESR. Meters also report the dissipation factor for capacitors and for inductors, and measure at a chosen frequency because real parts change with it (lesson 4).
Accuracy
Each method is only as good as its reference: the resistor's tolerance in a timing measurement, the known capacitor's in a resonance one. Stray capacitance from leads and probes adds picofarads, which matters for small capacitors, and is removed by measuring with the part disconnected and subtracting.
Worked example
An unknown inductor rings at 15.9 kHz with a known 10 nF capacitor. What is it?
Show the solution
- Resonance. The ringing frequency is
- Solve for L.
Answer the inductor is 10 mH.
Worked example
A 5 V pulse across an inductor raises its current by 0.4 A in 2 µs. What is its inductance?
Show the solution
- Inductance from the ramp.
- Spotting saturation. If a later 2 µs raised it by 1.2 A, the inductance would have fallen to a third: saturation.
Answer the inductance is 25 µH.
Worked example
An unknown inductor rings at 15.9 kHz with a 10 nF capacitor, and the ringing's amplitude halves every 10 cycles. What are its inductance, Q and series resistance?
Show the solution
- Inductance.
- Q from the decay. The amplitude decays as after n cycles, so halving in 10 cycles means
- Series resistance.
- One measurement. One ring-down measurement, with a known capacitor and a scope, gives all three.
Answer the inductance is 10.0 mH, Q is 45, and the series resistance is 22 Ω.
Check
Charging through 1 kΩ takes a time constant of 1 ms. What is the capacitance?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
Check
A capacitor charging toward 5 V through 10 kΩ takes 0.5 ms to go from 1 V to 3.5 V. What is C?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
Check
An inductor rings at 10 kHz with a 1 nF capacitor. What is its inductance?
Write units the way you normally would: 1.5 mH, 1500 µH and 0.0015 H are the same answer.
Check
An LCR meter at 1 kHz measures a capacitor's reactance as 10 Ω. What is its capacitance?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
Check
A 10 µF capacitor has 1 Ω of ESR at 1 kHz. What is its dissipation factor?
Check
5 V across an inductor raises its current by 0.5 A in 2 µs. What is L?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
An unknown inductor rings at 15.9 kHz with a known 1 nF capacitor, and its amplitude halves every 20 cycles.
(a)
What's its inductance?
Write units the way you normally would: 1.5 mH, 1500 µH and 0.0015 H are the same answer.
(b)
What's its Q?
Check
A coil rings at f with a known capacitor C, and halves in amplitude every n cycles.
Step 1
What's its inductance?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's its Q?
Step 3
What's its series resistance, ?
Explain why
Why does a careful timing measurement of capacitance use two thresholds instead of timing from the moment charging starts?
Timing from zero needs the exact instant charging began and an exactly empty capacitor, and both are uncertain: the switch takes time to act, and a little residual charge shifts the curve. Between two thresholds on the same charging curve, the elapsed time depends only on RC and the two threshold voltages relative to the final voltage, . Any delay or leftover charge only moves both crossings together and cancels out of the difference.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.