C2 · Lesson 16 · Parallel RLC and damping
Characteristic roots, and three ways a second-order circuit settles
Lesson 15 rang a series RLC circuit. Put the same three parts in parallel and the circuit still rings, but the resistor's role reverses: in series a small resistance lets it ring, while in parallel a large one does. Both are second-order circuits, and both settle in one of three ways, overdamped, critically damped or underdamped, decided by two numbers: how fast energy drains away and how fast it sloshes between the capacitor and the inductor. Seeing both through their characteristic roots makes the pattern general.
- A current step drives R, L and C in parallel. The inductor eventually takes all the current, so the voltage returns to zero; how it gets there is the natural response.
- Raise R: the ringing lasts longer. Lower it toward a few hundred ohms: the ringing disappears.
- Find the R where it just stops ringing: critical damping.
Predict
A parallel RLC circuit rings too long. To damp it, you should:
Decrease R. In parallel, the resistor drains energy through the current it draws, , so a smaller R drains faster. Removing it (infinite R) would leave a lossless LC that rings forever. In a series circuit it's the opposite: a series resistor drains energy as , so a larger R damps more.
Name it
The characteristic equation
Any circuit with one inductor and one capacitor (and resistors) obeys a second-order differential equation, and its natural response is a sum of terms , where solves
with resonant frequency and decay rate α:
| Circuit | α | Damping ratio ζ = α/ω₀ |
|---|---|---|
| series RLC | ||
| parallel RLC |
Three cases
- Overdamped (ζ > 1, ): two real roots, a sum of two decaying exponentials, no ringing. The slower root, , sets how long it takes.
- Critically damped (ζ = 1): one repeated root; the fastest response with no overshoot, .
- Underdamped (ζ < 1): complex roots , ringing at the damped frequency inside an envelope . The response settles to within 2% after about .
Critical resistance
Setting ζ = 1 gives the resistance that just stops ringing: in series and in parallel. The quantity , the circuit's characteristic impedance, sets the scale of every RLC design, and returns for transmission lines (C10).
Worked example
A parallel RLC has L = 10 mH, C = 100 nF and R = 1 kΩ. Find α, ω₀, ζ and the ringing frequency.
Show the solution
- Decay rate.
- Natural frequency.
- Damping ratio. so it's underdamped.
- Ringing frequency. or 4.97 kHz.
- Settling time. It settles in about = 0.8 ms.
Answer α = 5000/s, ω₀ = 31,600 rad/s and ζ = 0.16 (underdamped), and it rings at 31,200 rad/s, or 4.97 kHz.
Worked example
What resistance critically damps the same L and C, in parallel and in series?
Show the solution
- The characteristic resistance.
- In parallel.
- In series.
Answer 158 Ω damps it critically in parallel, and 632 Ω in series.
Worked example
A parallel tank at 1 MHz uses 10 µH, and its losses look like 10 kΩ in parallel. What capacitance tunes it, and what are its Q and bandwidth?
Show the solution
- Tuning capacitance.
- Q. For a parallel tank,
- Bandwidth.
- Compare with a series circuit. A larger parallel resistance (fewer losses) raises Q, the opposite of a series circuit, where less series resistance does.
- Where it's used. Radio front ends used tanks like this to pick one station from the band.
Answer 2.53 nF tunes it, giving a Q of 159 and a bandwidth of 6.3 kHz.
Check
A parallel RLC has R = 1000 Ω and C = 10 nF. What is its decay rate α, in per second?
Check
A parallel RLC has R = 200 Ω, L = 1 mH and C = 100 nF. What is its damping ratio?
Check
What parallel resistance critically damps L = 10 mH and C = 10 nF?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A parallel RLC (L = 1 mH, C = 10 nF, R = 200 Ω) rings. At what frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A series RLC has R = 500 Ω, L = 1 mH and C = 10 µF, which makes it overdamped. What is its slower characteristic root, in per second?
Check
A series RLC with R = 1 Ω and L = 1 mH rings. Roughly how long does it take to settle within 2%?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A parallel tank tuned to 1 MHz uses 1 µH with 20 kΩ of loss in parallel.
(a)
What capacitance tunes it?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
(b)
What's its Q?
Check
A parallel RLC with R, L and C.
Step 1
What's α?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's ζ?
Step 3
What's Q?
Explain why
Why does a large resistor damp a series RLC circuit, but a small one damp a parallel RLC circuit?
In a series circuit the same current flows through everything, and the resistor removes energy at the rate : a bigger R drains more energy per cycle, so it damps more. In a parallel circuit the same voltage is across everything, and the resistor removes energy at : a smaller R draws more current from that voltage and drains more energy. In each case damping is about how much energy the resistor removes compared with how much is sloshing between the capacitor and the inductor.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.