C3 · Lesson 27 · Project
Make a load look like the source it needs, at one frequency
A 50 Ω radio transmitter must drive an antenna that, at the operating frequency, looks like 200 Ω. Connected directly, the mismatch reflects a third of the power. Two components, an inductor and a capacitor arranged as an L, transform the 200 Ω into exactly 50 Ω at that frequency, and all the available power goes into the antenna. In this project you'll design such L-networks, verify them with your complex-impedance tools, and sweep them to see how narrow a match is.
- An L-network matches a source to a load (larger) at : a series inductor on the source side, a shunt capacitor across the load. The curve is the fraction of the available power reaching the load, against frequency.
- At it's exactly 1. The match narrows as the ratio grows, because the network's Q grows.
- The readouts give the component values for the design.
Predict
A 50 Ω source drives a 200 Ω load directly. What share of its available power reaches the load?
64%. The reflection coefficient is , so of the available power is reflected and 64% delivered. A matching network recovers the missing 36% at its design frequency.
Name it
The L-network
To match a smaller resistance to a larger at angular frequency ω, put a series reactance on the low side and a shunt reactance across the high side, with
Why it works: the shunt reactance across turns it, viewed as a series circuit, into plus some reactance (a parallel-to-series conversion, lesson 13), and the series reactance cancels that reactance (lesson 9).
Choosing parts
For a low-pass L, the series element is an inductor and the shunt a capacitor:
It also attenuates harmonics, which a transmitter needs. If the source is the larger resistance, mirror the network: shunt capacitor across the source, series inductor to the load.
Bandwidth
The match is exact only at . The network's Q sets how fast it degrades, roughly a loaded bandwidth of : large transformation ratios mean high Q and narrow bandwidth. Wider bandwidth takes more sections (two L's in cascade, each doing part of the ratio) or a transformer.
Checking a design
Compute the input impedance of the network with the load attached (lesson 25), and the share of available power delivered, with .
Worked example
Design a low-pass L-network matching 50 Ω to 200 Ω at 10 MHz.
Show the solution
- Q of the match.
- Series reactance.
- Shunt reactance.
- Inductor. In series from the source:
- Capacitor. Across the load:
Answer a 1.38 µH inductor in series from the source and a 138 pF capacitor across the load.
Worked example
Check it: what does the source see at 10 MHz?
Show the solution
- Load in parallel with the capacitor.
- Add the inductor. Its Ω cancels the reactance:
- Off frequency. At 20 MHz the same network passes only 16% of the available power, and at 5 MHz 76%, so the match is narrow.
Answer the source sees exactly 50 Ω at 10 MHz.
Check
What Q does an L-network matching 25 Ω to 100 Ω have?
Check
For that match (25 Ω to 100 Ω), what series reactance is on the 25 Ω side?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
And what shunt reactance goes across the 100 Ω load?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What inductor has 50 Ω of reactance at 7 MHz?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
What capacitor has 50 Ω of reactance at 7 MHz?
Write units the way you normally would: 1.5 pF and 0.0015 nF are the same answer.
Check
A 50 Ω source drives a 10 Ω load directly. What percentage of the available power reaches it?
Check
Write lmatch(RS, RL, f): return (L, C, topology) for a low-pass L-network matching RS to RL at f Hz, with topology = 'series-first' when RS < RL (series L from the source, shunt C across the load) and 'shunt-first' otherwise (shunt C across the source, series L to the load).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
Write zin(L, C, RL, f, topology): the complex impedance the source sees looking into the network with RL attached, and delivered(L, C, RS, RL, f, topology): the share of available power reaching the load, .
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
How can two lossless components make a 200 Ω load look like 50 Ω, without wasting any power?
A capacitor in parallel with the 200 Ω load changes how it looks: at the design frequency the combination is equivalent to 50 Ω in series with a capacitive reactance. The series inductor's reactance is chosen to cancel that capacitive part exactly, leaving a pure 50 Ω for the source. Inductors and capacitors store and return energy without dissipating it, so all the power the source delivers into that 50 Ω ends up in the 200 Ω load, now at a higher voltage and lower current, as a transformer would deliver it. The trick works only at one frequency, because the reactances change with frequency.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.