C323 of 29
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C3 · Lesson 23 · Poynting flow in an AC circuit

Energy flowing through space to the load, and back

In B4.11 you saw that the energy delivered by a battery travels through the space around the wires, carried by the electric and magnetic fields, as the Poynting vector 𝐒=𝐄×𝐇. With AC, both fields reverse 120 times a second. For a resistive load they reverse together, so their product still points toward the load: energy always flows one way. For a reactive load they fall out of step, and for part of every cycle the energy flows back toward the source. That's reactive power, seen in the fields.

Play

  • A side view of a two-wire line feeding a load at the right. The arrows show the energy flow, 𝐄×𝐇, between and around the wires. Press Play (slowed so one cycle takes four seconds).
  • Set the load's angle to 0° (a resistor). Does the flow ever reverse?
  • Raise the angle toward 90°. When does energy flow back toward the source?

Predict

A purely capacitive load is connected to an AC line. On average, which way does the energy flow along the line?

Name it

The fields carry the power

Where the energy goes. Between two wires carrying opposite charges and opposite currents, the electric field runs from one wire to the other and the magnetic field circles each wire. In the region between them, 𝐄×𝐇 points along the line. Integrating 𝐒 over any plane that cuts the line gives exactly vi, the power passing that point (B4.11).

With AC. The voltage sets E and the current sets H. With v∝cos⁡ωt and i∝cos⁡(ωt−ϕ):

S∝cos⁡ωtcos⁡(ωt−ϕ)=12[cos⁡ϕ+cos⁡(2ωt−ϕ)]

the same expression as p(t) in lesson 16.

  • Resistive load (ϕ=0): S∝cos2⁡ωt≥0, always toward the load, pulsing at twice the frequency.
  • Reactive load (ϕ=±90°): S alternates in direction, averaging zero.
  • In between: mostly forward, with brief reversals, averaging cos⁡ϕ of the peak.

What this explains.

  • Reactive power is real energy moving through the fields, back and forth; it heats the wires on the way, though no work is done at the load.
  • The pulsing at 2ω is why a single-phase motor vibrates at 100 or 120 Hz. Three-phase systems use three lines 120° apart, whose powers add to a constant, so big motors run smoothly.
  • At high frequencies, the same fields carry signals along transmission lines and radiate from antennas (C10).

Worked example

A load draws 10 A from 120 V at pf 0.8. What is the average power, and how far does the instantaneous power swing?

Show the solution
  1. Average power. P=120×10×0.8=960W
  2. Lowest instantaneous power. It dips to pmin=VI(cos⁡φ−1)=−240W when energy flows back to the source.
  3. Highest instantaneous power. pmax=VI(1+cos⁡φ)=2160W

Answer the average power is 960 W, and the instantaneous power swings from −240 W to 2160 W.

Worked example

A resistor carries 1 A with 10 V across it. Where does its 10 W enter it, according to the Poynting picture?

Show the solution
  1. The fields. The field along the resistor and the magnetic field circling it give a Poynting vector pointing radially inward.
  2. The total. Integrated over the surface it totals VI = 10 W.
  3. Where the energy travels. The energy travels through the space around the wires rather than inside them.

Answer the 10 W enters through the resistor's sides, flowing radially inward.

Worked example

A coaxial cable with 50 Ω characteristic impedance carries 100 W to a matched load. What voltage and current does that take, and where does the power travel?

Show the solution
  1. Voltage. On a matched line P=V2Z0, so V=100×50=70.7V RMS
  2. Current. I=70.750=1.41A
  3. Where the power travels. The power doesn't travel in the copper: the Poynting vector, 𝐄×𝐇, is nonzero only in the dielectric between the conductors, where the radial electric field and the circular magnetic field cross.
  4. What the conductors do. The conductors guide the field and carry the current that sustains it; the energy flows in the space between them.

Answer 70.7 V RMS and 1.41 A, with the power traveling in the dielectric between the conductors.

Check

A load's current lags its voltage by 30°. On average, how much power reaches it, as a fraction of VI?

Check

On a 60 Hz line, at what frequency does the Poynting flow (and p(t)) pulse?

Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.

Check

A load draws 2 A RMS at 120 V RMS with a 60° angle. What is the largest instantaneous power flowing toward it?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

Same load: 2 A, 120 V, 60°. What is the most negative instantaneous power, when energy flows back toward the source?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

Why do large motors usually run on three-phase power?

Check

A matched 50 Ω cable carries 100 W.

(a)

What RMS voltage does it need?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What RMS current?

Check

A matched line of impedance Z carries power P.

Step 1

What's its voltage?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

How do the fields around a power line show the difference between real and reactive power?

Practice

Keep practicing

8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.