title: Poynting flow in an AC circuit
heading: Energy flowing through space to the load, and back
eyebrow: C3 · Lesson 23 · Poynting flow in an AC circuit
xp: 40
---

::: hook
In B4.11 you saw that the energy delivered by a battery travels through the space around the wires, carried by the electric and magnetic fields, as the Poynting vector $\mathbf S = \mathbf E \times \mathbf H$. With AC, both fields reverse 120 times a second. For a resistive load they reverse together, so their product still points toward the load: energy always flows one way. For a reactive load they fall out of step, and for part of every cycle the energy flows back toward the source. That's reactive power, seen in the fields.

::: play
- A side view of a two-wire line feeding a load at the right. The arrows show the energy flow, $\mathbf E \times \mathbf H$, between and around the wires. Press Play (slowed so one cycle takes four seconds).
- Set the load's angle to 0° (a resistor). Does the flow ever reverse?
- Raise the angle toward 90°. When does energy flow back toward the source?
:::
:::

```sim plot
view: flow
x: x = -3..3 m
y: y = -1.5..1.5 m
time: tt
slider: phi = 0..90 step 5 = 0 °
dx: step(2.5 - x)*cos(2*pi*tt/4)*cos(2*pi*tt/4 - phi*pi/180)*((y - 0.5)/((y - 0.5)^2 + 0.004) - (y + 0.5)/((y + 0.5)^2 + 0.004))^2
dy: 0
arrows: scaled
heads: on
grid: 16
path: u, 0.5 | over: u = -3..2.5 | label: wire (+)
path: u, -0.5 | over: u = -3..2.5 | label: wire (−)
path: 2.5, u | over: u = -0.5..0.5 | label: load
readout: power now (÷ S) = 2*cos(2*pi*tt/4)*cos(2*pi*tt/4 - phi*pi/180)
readout: average power (÷ S) = cos(phi*pi/180)
```

::: predict
## A purely capacitive load is connected to an AC line. On average, which way does the energy flow along the line?

- [ ] Toward the load
- [ ] Toward the source
- [x] Neither: equal amounts flow each way during each cycle
- [ ] It doesn't flow at all

::: reveal
Neither, on average. For a quarter cycle the fields carry energy into the capacitor's electric field, and for the next quarter they carry it back out. The Poynting vector oscillates at twice the line frequency and averages to zero. Energy is constantly moving, but none is delivered.
:::
:::

::: nameit
## The fields carry the power

**Where the energy goes.** Between two wires carrying opposite charges and opposite currents, the electric field runs from one wire to the other and the magnetic field circles each wire. In the region between them, $\mathbf E \times \mathbf H$ points along the line. Integrating $\mathbf S$ over any plane that cuts the line gives exactly $vi$, the power passing that point (B4.11).

**With AC.** The voltage sets E and the current sets H. With $v \propto \cos\omega t$ and $i \propto \cos(\omega t - \phi)$:

$$S \propto \cos\omega t\,\cos(\omega t - \phi) = \tfrac12\left[\cos\phi + \cos(2\omega t - \phi)\right]$$

the same expression as $p(t)$ in lesson 16.

- **Resistive load** ($\phi = 0$): $S \propto \cos^2\omega t \geq 0$, always toward the load, pulsing at twice the frequency.
- **Reactive load** ($\phi = \pm90°$): $S$ alternates in direction, averaging zero.
- **In between:** mostly forward, with brief reversals, averaging $\cos\phi$ of the peak.

**What this explains.**

- Reactive power is real energy moving through the fields, back and forth; it heats the wires on the way, though no work is done at the load.
- The pulsing at $2\omega$ is why a single-phase motor vibrates at 100 or 120 Hz. **Three-phase** systems use three lines 120° apart, whose powers add to a constant, so big motors run smoothly.
- At high frequencies, the same fields carry signals along transmission lines and radiate from antennas (C10).
:::

::: example
## A load draws 10 A from 120 V at pf 0.8. What is the average power, and how far does the instantaneous power swing?

::: solution
1. **Average power.**
   $$\begin{aligned} P &= 120 \times 10 \times 0.8 \\ &= 960\ \text{W} \end{aligned}$$
2. **Lowest instantaneous power.** It dips to
   $$\begin{aligned} p_\text{min} &= VI(\cos\varphi - 1) \\ &= -240\ \text{W} \end{aligned}$$
   when energy flows back to the source.
3. **Highest instantaneous power.**
   $$\begin{aligned} p_\text{max} &= VI(1 + \cos\varphi) \\ &= 2160\ \text{W} \end{aligned}$$

**Answer:** the average power is 960 W, and the instantaneous power swings from −240 W to 2160 W.
:::
:::

::: example
## A resistor carries 1 A with 10 V across it. Where does its 10 W enter it, according to the Poynting picture?

::: solution
1. **The fields.** The field along the resistor and the magnetic field circling it give a Poynting vector pointing radially inward.
2. **The total.** Integrated over the surface it totals $VI$ = 10 W.
3. **Where the energy travels.** The energy travels through the space around the wires rather than inside them.

**Answer:** the 10 W enters through the resistor's sides, flowing radially inward.
:::
:::

::: example
## A coaxial cable with 50 Ω characteristic impedance carries 100 W to a matched load. What voltage and current does that take, and where does the power travel?

::: solution
1. **Voltage.** On a matched line $P = \frac{V^2}{Z_0}$, so
   $$\begin{aligned} V &= \sqrt{100 \times 50} \\ &= 70.7\ \text{V RMS} \end{aligned}$$
2. **Current.**
   $$\begin{aligned} I &= \frac{70.7}{50} \\ &= 1.41\ \text{A} \end{aligned}$$
3. **Where the power travels.** The power doesn't travel in the copper: the Poynting vector, $\mathbf E \times \mathbf H$, is nonzero only in the dielectric between the conductors, where the radial electric field and the circular magnetic field cross.
4. **What the conductors do.** The conductors guide the field and carry the current that sustains it; the energy flows in the space between them.

**Answer:** 70.7 V RMS and 1.41 A, with the power traveling in the dielectric between the conductors.
:::
:::

::: check
given: phi = 0 | 30 | 60 | 80
answer: cos(phi*pi/180)
tolerance: 0.5%

## A load's current lags its voltage by {phi}°. On average, how much power reaches it, as a fraction of $VI$?

::: right
Right. The average of $p(t) = VI[\cos\phi + \cos(2\omega t - \phi)]$ is $VI\cos\phi$: {answer} of $VI$.
:::

::: misses
- [sin(phi*pi/180)] That's the reactive part.
- [any] Not yet. The average is $\cos\phi$.
:::
:::

::: check
given: f = 50 | 60 | 400
answer: 2*f
unit: Hz
tolerance: 0.5%

## On a {f} Hz line, at what frequency does the Poynting flow (and p(t)) pulse?

::: right
Right. Twice the line frequency: {answer}.
:::

::: misses
- [f] The product of two sinusoids at f contains $2f$.
- [any] Not yet. $\cos^2$ varies at twice the frequency.
:::
:::

::: check
given: V = 120 | 230; I = 2 | 5; phi = 30 | 60
answer: V*I*(1 + cos(phi*pi/180))
unit: W
tolerance: 0.5%

## A load draws {I} A RMS at {V} V RMS with a {phi}° angle. What is the largest instantaneous power flowing toward it?

::: right
Right. $p(t) = VI[\cos\phi + \cos(2\omega t - \phi)]$ peaks at $VI(1 + \cos\phi)$ = {answer}.
:::

::: misses
- [V*I*cos(phi*pi/180)] That's the average. The peak adds VI.
- [2*V*I] That's the peak only for a resistive load.
- [any] Not yet. Maximize $VI[\cos\phi + \cos(2\omega t - \phi)]$.
:::
:::

::: check
given: V = 120 | 230; I = 2 | 5; phi = 30 | 60
answer: V*I*(cos(phi*pi/180) - 1)
unit: W
tolerance: 0.5%

## Same load: {I} A, {V} V, {phi}°. What is the most negative instantaneous power, when energy flows back toward the source?

::: right
Right. $VI(\cos\phi - 1)$ = {answer}.
:::

::: misses
- [-V*I] That's for a purely reactive load.
- [0] With φ ≠ 0, the flow reverses for part of each cycle.
- [any] Not yet. Minimize $VI[\cos\phi + \cos(2\omega t - \phi)]$.
:::
:::

::: check
kind: choice

## Why do large motors usually run on three-phase power?

- [ ] Three-phase uses less copper only
- [x] The three phases' instantaneous powers add to a constant, so the motor gets smooth power instead of pulses at twice the line frequency
- [ ] Single-phase can't make a motor turn
- [ ] Three-phase has no reactive power

::: right
Right. Three sinusoids 120° apart have $\cos^2$ terms that sum to a constant.
:::

::: misses
- [1] It does save copper, but the smooth power is the key benefit for motors.
- [3] Single-phase motors exist, with extra starting tricks.
- [4] Three-phase loads can still draw reactive power.
:::
:::

::: check
kind: parts
given: P = 10 | 100 | 1000; Z = 50 | 75

## A matched {Z} Ω cable carries {P} W.

::: part
answer: sqrt(P*Z)
unit: V
tolerance: 0.5%

### What RMS voltage does it need?

::: misses
- [any] $V = \sqrt{PZ_0}$.
:::
:::

::: part
answer: sqrt(P/Z)
unit: A
tolerance: 0.5%

### What RMS current?

::: misses
- [any] $I = \sqrt{P/Z_0}$.
:::
:::
:::

::: check
kind: derivation
vars: P = 0.001..10000, Z = 10..600

## A matched line of impedance Z carries power P.

::: step
answer: sqrt(P*Z)

### What's its voltage?
:::

::: step
answer: sqrt(P/Z)

### What's its current?
:::

::: right
Right. The ratio of voltage to current is the line's impedance.
:::
:::

::: explain
## How do the fields around a power line show the difference between real and reactive power?

::: model
The energy flow is the Poynting vector, set by the electric field (from the voltage) times the magnetic field (from the current). With a resistive load the two fields reverse together, so their product always points toward the load: energy flows one way, pulsing at twice the line frequency. With a reactive load the current is a quarter cycle out of step, so for half of each cycle the product points back toward the source. The energy then sloshes back and forth through the fields with no net delivery, which is reactive power.
:::
:::

::: practice

::: check
given: phi = 0 | 45 | 90
answer: cos(phi*pi/180)
tolerance: 1%

## Load angle {phi}°. Average power as a fraction of VI?

::: misses
- [any] $\cos\phi$.
:::
:::

::: check
given: f = 25 | 40 | 50 | 60 | 100 | 400
answer: 3*f
unit: Hz
tolerance: 0.5%

## In a three-phase {f} Hz system, how many voltage peaks per second are there across the three lines together?

::: misses
- [f] Count all three lines: each peaks once per cycle.
- [any] Three peaks per cycle.
:::
:::

::: check
given: V = 100 | 200; I = 1 | 4
answer: 2*V*I
unit: W
tolerance: 0.5%

## A resistive load at {V} V RMS draws {I} A RMS. What's the peak instantaneous power?

::: misses
- [V*I] That's the average. The peak is twice it.
- [any] $2VI$ for φ = 0.
:::
:::
:::