C552 of 57
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C5 · Lesson 52 · Series voltage regulators

A Zener reference, an emitter follower to carry the current, and a limit for when things go wrong

A Zener regulator has to pass the whole load current through its series resistor, and its Zener burns whatever the load doesn't take. For a few milliamps that's fine; for half an amp it means a Zener dissipating watts. The fix is to let the Zener set the voltage and let a transistor carry the current: an emitter follower whose base sits on the Zener. Add a sense resistor and one more transistor, and the regulator also survives a short circuit. This is the heart of the power supply you'll build next.

Play

  • A 6.2 V Zener, fed through 1 kΩ, holds the base of a pass transistor; the transistor's emitter is the output.
  • Vary the load from 1 kΩ down to 10 Ω. The output barely moves, while the Zener's current changes only by the base current.
  • Now lower the input toward 9 V with a heavy load. When does the output start to sag, and why?

Predict

The regulator above supplies 115 mA to the load with β = 100. How much of that current must come through the Zener's resistor?

Name it

The emitter-follower regulator

The Zener fixes the base, and the output follows a VBE below it:

Vout≈VZ−VBE.

The Zener's resistor only has to supply the base current, ILβ+1, plus the Zener's minimum:

RB≤Vin,min−VZIZ,min+IL,max/(β+1).

A Darlington pass device divides the base current by β twice, for loads of amps.

Regulation

  • Line: the output follows the Zener, which moves by rzRB+rz of an input change, as in a plain Zener regulator.
  • Load: more load current raises VBE by VTln⁡I2I1 (60 mV per decade), and the extra base current pulls the Zener node down through rz∥RB. The small-signal output resistance is
Rout≈re+rz∥RBβ+1.

Precision regulators compare the output with a reference in an op-amp loop and correct both errors (C6).

Dissipation and dropout

The pass transistor drops Vin−Vout at the full load current:

P=(Vin−Vout)IL,η≈VoutVin.

It needs a volt or two across it to stay active, and the input must stay high enough for RB to feed the base at full load; below that the output drops out and follows the input down.

Current limiting

Put a sense resistor RS in series with the output and a second transistor across it, collector to the pass transistor's base. When ILRS reaches a VBE, the second transistor turns on and steals base drive:

Ilim≈VBERS.

Into a short, the pass transistor holds Ilim with nearly the whole input across it, often more dissipation than at full load. Foldback limiting lowers the limit as the output voltage falls. In this simple follower the sense resistor's drop, ILRS, also comes off the output.

Worked example

Design a regulator for about 5 V at up to 500 mA from an input of 9 to 12 V, using a 5.6 V Zener (5 mA minimum) and a pass transistor with β = 50. Compare it with a plain Zener regulator.

Show the solution
  1. Output voltage. 5.6−0.7=4.9V
  2. Base current. The base needs up to 0.551 = 9.8 mA.
  3. Base resistor. RB≤9−5.65mA+9.8mA=230Ω Use 220 Ω.
  4. Zener with no load. At 12 V it takes 12−5.6220 = 29 mA and dissipates 0.16 W.
  5. Pass transistor. Its worst case is 12 V at 500 mA: (12−4.9)×0.5=3.55W so it needs a heat sink.
  6. Efficiency. It is 41% at 12 V and 54% at 9 V.
  7. Compare with a plain Zener regulator. That would need RS≤3.40.505 = 6.7 Ω, and with the load removed at 12 V its Zener would dissipate 5.3 W.

Answer a 5.6 V Zener with RB = 220 Ω gives 4.9 V; the pass transistor needs a heat sink for 3.55 W, while a plain Zener regulator would need 6.7 Ω and its Zener would dissipate 5.3 W with no load.

Worked example

In that regulator (rz = 10 Ω), how much does the output fall as the load rises from 50 mA to 500 mA?

Show the solution
  1. The pass transistor's VBE. It rises by VTln⁡10 = 59.5 mV for ten times the current.
  2. The Zener node. The base current rises from 0.98 mA to 9.8 mA, and that extra 8.8 mA pulls the Zener node down through rz∥RB = 9.57 Ω, by 84 mV.
  3. Total. In all the output falls about 144 mV, 2.9%.
  4. How good this is. A plain follower regulator is good to a few percent; better needs feedback.

Answer the output falls about 144 mV, 2.9%.

Worked example

Add current limiting at about 600 mA with a sense transistor that turns on at 0.65 V. What sense resistor, and what does the pass transistor dissipate into a short from 12 V?

Show the solution
  1. Sense resistor. RS=0.650.6=1.08Ω Use 1.1 Ω, which limits at 0.651.1 = 591 mA.
  2. Into a short. The pass transistor has 12 − 0.65 V across it at 591 mA: (12−0.65)×0.591=6.7W That's almost twice its full-load dissipation, so either the heat sink is sized for the short or the limit folds back.
  3. Cost in normal use. At a 500 mA load, the sense resistor drops 0.55 V from the output, which is why real regulators put it inside a feedback loop.

Answer use 1.1 Ω, which limits at 591 mA; into a short the pass transistor dissipates 6.7 W.

Check

An emitter-follower regulator's base sits on a 5.6 V Zener. About what's its output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A follower regulator with a 6.8 V Zener (5 mA minimum) and a pass transistor with β = 30 supplies up to 1 A from 9 to 15 V.

(a)

What's the largest RB?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

What's the pass transistor's worst-case dissipation?

Check

A series regulator gives 3.3 V at 1 A from 12 V.

(a)

What does its pass transistor dissipate?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

What's its efficiency, ignoring the reference's current?

Check

A follower regulator from 24 V limits at 0.1 A with a sense transistor that turns on at 0.6 V.

(a)

What sense resistor?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

(b)

What does the pass transistor dissipate into a short?

Check

A follower regulator's load current rises by a factor of 5. How much does the pass transistor's VBE rise, taking the output down with it?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

A follower regulator's Zener (rz = 5 Ω) is fed through 220 Ω. How much does the output move when the input rises 4 V?

Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.

Check

Why does a series regulator with a pass transistor run its Zener far cooler than a plain Zener regulator for the same load?

Check

A follower regulator with Zener voltage z (rz = r) and pass gain b supplies up to I from an input of at least a, keeping m in the Zener.

Step 1

What's its output voltage?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does an emitter-follower regulator dissipate more in its pass transistor during a short circuit than at full load?

Practice

Keep practicing

9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.