title: Series voltage regulators
heading: A Zener reference, an emitter follower to carry the current, and a limit for when things go wrong
eyebrow: C5 · Lesson 52 · Series voltage regulators
xp: 40
---

::: hook
A Zener regulator has to pass the whole load current through its series resistor, and its Zener burns whatever the load doesn't take. For a few milliamps that's fine; for half an amp it means a Zener dissipating watts. The fix is to let the Zener set the voltage and let a transistor carry the current: an emitter follower whose base sits on the Zener. Add a sense resistor and one more transistor, and the regulator also survives a short circuit. This is the heart of the power supply you'll build next.

::: play
- A 6.2 V Zener, fed through 1 kΩ, holds the base of a pass transistor; the transistor's emitter is the output.
- Vary the load from 1 kΩ down to 10 Ω. The output barely moves, while the Zener's current changes only by the base current.
- Now lower the input toward 9 V with a heavy load. When does the output start to sag, and why?
:::
:::

```sim circuit
VIN vin 0 15                 @ 0,0 down 7
RB vin b 1k                  @ 2,0 down 3
DZ 0 b BV=6.2                @ 2,7 up 4
Q1 vin b out npn BF=100      @ 4,3
RL out 0 47                  @ 5,4 down 3
slider: VIN.amp 8..20
slider: RL 10..1k log
scope: v(b), v(out)
time: 0..1m s
meter: v(out), i(Q1.e), i(DZ)
```

::: predict
## The regulator above supplies 115 mA to the load with β = 100. How much of that current must come through the Zener's resistor?

- [ ] All 115 mA
- [x] About 1.1 mA, the base current
- [ ] None
- [ ] Half of it

::: reveal
Only the base current, $\frac{115\text{ mA}}{101}$ = 1.1 mA. The load current flows from the input through the transistor's collector. The 1 kΩ resistor carries 8.8 mA from 15 V, so the Zener keeps 7.7 mA and stays in breakdown. A plain Zener regulator would need a resistor small enough to pass the full 115 mA, and its Zener would dissipate 0.7 W with the load removed.
:::
:::

::: nameit
## The emitter-follower regulator

The Zener fixes the base, and the output follows a $V_{BE}$ below it:

$$V_\text{out} \approx V_Z - V_{BE}.$$

The Zener's resistor only has to supply the base current, $\frac{I_L}{\beta + 1}$, plus the Zener's minimum:

$$R_B \le \frac{V_\text{in,min} - V_Z}{I_{Z,\text{min}} + I_{L,\text{max}}/(\beta + 1)}.$$

A Darlington pass device divides the base current by β twice, for loads of amps.

## Regulation

- **Line:** the output follows the Zener, which moves by $\frac{r_z}{R_B + r_z}$ of an input change, as in a plain Zener regulator.
- **Load:** more load current raises $V_{BE}$ by $V_T\ln\frac{I_2}{I_1}$ (60 mV per decade), and the extra base current pulls the Zener node down through $r_z \parallel R_B$. The small-signal output resistance is

$$R_\text{out} \approx r_e + \frac{r_z \parallel R_B}{\beta + 1}.$$

Precision regulators compare the output with a reference in an op-amp loop and correct both errors (C6).

## Dissipation and dropout

The pass transistor drops $V_\text{in} - V_\text{out}$ at the full load current:

$$P = (V_\text{in} - V_\text{out})I_L, \qquad \eta \approx \frac{V_\text{out}}{V_\text{in}}.$$

It needs a volt or two across it to stay active, and the input must stay high enough for $R_B$ to feed the base at full load; below that the output **drops out** and follows the input down.

## Current limiting

Put a sense resistor $R_S$ in series with the output and a second transistor across it, collector to the pass transistor's base. When $I_LR_S$ reaches a $V_{BE}$, the second transistor turns on and steals base drive:

$$I_\text{lim} \approx \frac{V_{BE}}{R_S}.$$

Into a short, the pass transistor holds $I_\text{lim}$ with nearly the whole input across it, often more dissipation than at full load. **Foldback** limiting lowers the limit as the output voltage falls. In this simple follower the sense resistor's drop, $I_LR_S$, also comes off the output.
:::

::: example
## Design a regulator for about 5 V at up to 500 mA from an input of 9 to 12 V, using a 5.6 V Zener (5 mA minimum) and a pass transistor with β = 50. Compare it with a plain Zener regulator.

::: solution
1. **Output voltage.**
   $$5.6 - 0.7 = 4.9\ \text{V}$$
2. **Base current.** The base needs up to $\frac{0.5}{51}$ = 9.8 mA.
3. **Base resistor.**
   $$\begin{aligned} R_B &\le \frac{9 - 5.6}{5\ \text{mA} + 9.8\ \text{mA}} \\ &= 230\ \Omega \end{aligned}$$
   Use 220 Ω.
4. **Zener with no load.** At 12 V it takes $\frac{12 - 5.6}{220}$ = 29 mA and dissipates 0.16 W.
5. **Pass transistor.** Its worst case is 12 V at 500 mA:
   $$(12 - 4.9) \times 0.5 = 3.55\ \text{W}$$
   so it needs a heat sink.
6. **Efficiency.** It is 41% at 12 V and 54% at 9 V.
7. **Compare with a plain Zener regulator.** That would need $R_S \le \frac{3.4}{0.505}$ = 6.7 Ω, and with the load removed at 12 V its Zener would dissipate 5.3 W.

**Answer:** a 5.6 V Zener with $R_B$ = 220 Ω gives 4.9 V; the pass transistor needs a heat sink for 3.55 W, while a plain Zener regulator would need 6.7 Ω and its Zener would dissipate 5.3 W with no load.
:::
:::

::: example
## In that regulator ($r_z$ = 10 Ω), how much does the output fall as the load rises from 50 mA to 500 mA?

::: solution
1. **The pass transistor's $V_{BE}$.** It rises by $V_T\ln 10$ = 59.5 mV for ten times the current.
2. **The Zener node.** The base current rises from 0.98 mA to 9.8 mA, and that extra 8.8 mA pulls the Zener node down through $r_z \parallel R_B$ = 9.57 Ω, by 84 mV.
3. **Total.** In all the output falls about 144 mV, 2.9%.
4. **How good this is.** A plain follower regulator is good to a few percent; better needs feedback.

**Answer:** the output falls about 144 mV, 2.9%.
:::
:::

::: example
## Add current limiting at about 600 mA with a sense transistor that turns on at 0.65 V. What sense resistor, and what does the pass transistor dissipate into a short from 12 V?

::: solution
1. **Sense resistor.**
   $$\begin{aligned} R_S &= \frac{0.65}{0.6} \\ &= 1.08\ \Omega \end{aligned}$$
   Use 1.1 Ω, which limits at $\frac{0.65}{1.1}$ = 591 mA.
2. **Into a short.** The pass transistor has 12 − 0.65 V across it at 591 mA:
   $$(12 - 0.65) \times 0.591 = 6.7\ \text{W}$$
   That's almost twice its full-load dissipation, so either the heat sink is sized for the short or the limit folds back.
3. **Cost in normal use.** At a 500 mA load, the sense resistor drops 0.55 V from the output, which is why real regulators put it inside a feedback loop.

**Answer:** use 1.1 Ω, which limits at 591 mA; into a short the pass transistor dissipates 6.7 W.
:::
:::

::: check
given: VZ = 3.9 | 5.6 | 9.1 | 12
answer: VZ - 0.7
unit: V
tolerance: 0.5%

## An emitter-follower regulator's base sits on a {VZ} V Zener. About what's its output?

::: right
Right. A $V_{BE}$ below the Zener: {answer}.
:::

::: misses
- [VZ] The output is the emitter, a $V_{BE}$ below the base.
- [VZ + 0.7] The emitter is below the base, not above.
- [any] $V_\text{out} \approx V_Z - V_{BE}$.
:::
:::

::: check
kind: parts
given: Vmin = 9 | 12; Vmax = 15 | 18; VZ = 5.6 | 6.8; IL = 0.2 | 1; b = 30 | 100

## A follower regulator with a {VZ} V Zener (5 mA minimum) and a pass transistor with β = {b} supplies up to {IL} A from {Vmin} to {Vmax} V.

::: part
answer: (Vmin - VZ)/(5 + IL*1000/(b + 1))*1000
unit: Ω
tolerance: 1%

### What's the largest $R_B$?

::: misses
- [(Vmin - VZ)/(5 + IL*1000)*1000] Only the base current, $I_L/(\beta + 1)$, flows through $R_B$.
- [any] $R_B \le \frac{V_\text{in,min} - V_Z}{I_{Z,\text{min}} + I_L/(\beta + 1)}$.
:::
:::

::: part
answer: (Vmax - VZ + 0.7)*IL
unit: W
tolerance: 1%

### What's the pass transistor's worst-case dissipation?

::: misses
- [(Vmin - VZ + 0.7)*IL] The worst case is at the highest input.
- [any] $(V_\text{in,max} - V_\text{out})I_L$.
:::
:::
:::

::: check
kind: parts
given: Vin = 9 | 12 | 15; Vout = 3.3 | 5; I = 0.1 | 0.5 | 1

## A series regulator gives {Vout} V at {I} A from {Vin} V.

::: part
answer: (Vin - Vout)*I
unit: W
tolerance: 0.5%

### What does its pass transistor dissipate?

::: misses
- [Vin*I] Only the voltage across the transistor counts.
- [any] $(V_\text{in} - V_\text{out})I_L$.
:::
:::

::: part
answer: Vout/Vin*100
unit: %
tolerance: 0.5%

### What's its efficiency, ignoring the reference's current?

::: misses
- [any] $\frac{V_\text{out}}{V_\text{in}}$.
:::
:::
:::

::: check
kind: parts
given: v = 0.6 | 0.65; I = 0.1 | 0.5 | 2; Vin = 9 | 24

## A follower regulator from {Vin} V limits at {I} A with a sense transistor that turns on at {v} V.

::: part
answer: v/I
unit: Ω
tolerance: 0.5%

### What sense resistor?

::: misses
- [any] $R_S = \frac{V_{BE}}{I_\text{lim}}$.
:::
:::

::: part
answer: (Vin - v)*I
unit: W
tolerance: 1%

### What does the pass transistor dissipate into a short?

::: misses
- [Vin*I] The sense resistor takes $V_{BE}$ of the input.
- [any] $(V_\text{in} - V_{BE})I_\text{lim}$.
:::
:::
:::

::: check
given: k = 2 | 5 | 10 | 100
answer: 25.85*ln(k)
unit: mV
tolerance: 0.5%

## A follower regulator's load current rises by a factor of {k}. How much does the pass transistor's $V_{BE}$ rise, taking the output down with it?

::: right
Right. $V_T\ln\frac{I_2}{I_1}$ = {answer}.
:::

::: misses
- [25.85*log(k)] Use the natural logarithm.
- [any] $\Delta V_{BE} = V_T\ln\frac{I_2}{I_1}$.
:::
:::

::: check
given: RB = 100 | 220 | 470; rz = 5 | 15; dV = 1 | 4
answer: dV*rz/(RB + rz)*1000
unit: mV
tolerance: 0.5%

## A follower regulator's Zener ($r_z$ = {rz} Ω) is fed through {RB} Ω. How much does the output move when the input rises {dV} V?

::: right
Right. The output follows the Zener: $\Delta V\frac{r_z}{R_B + r_z}$ = {answer}.
:::

::: misses
- [dV*rz/RB*1000] $R_B$ and $r_z$ form the divider in series.
- [any] $\Delta V_\text{in}\frac{r_z}{R_B + r_z}$.
:::
:::

::: check
kind: choice

## Why does a series regulator with a pass transistor run its Zener far cooler than a plain Zener regulator for the same load?

- [ ] The transistor cools the Zener
- [x] The Zener only supplies the base current, so its resistor can be large and its spare current small
- [ ] The transistor lowers the input voltage
- [ ] The Zener is switched off at full load

::: right
Right. The load current flows through the transistor, and the Zener's circuit only handles $\frac{1}{\beta + 1}$ of it.
:::

::: misses
- [1] There's no thermal connection; it's about current.
- [3] The input voltage is what it is; the transistor drops the difference.
- [4] The Zener stays in breakdown at every load, setting the voltage.
:::
:::

::: check
kind: derivation
vars: a = 6..30, z = 2..15, I = 0.01..3, b = 20..500, m = 0.001..0.02, r = 1..30

## A follower regulator with Zener voltage z ($r_z$ = r) and pass gain b supplies up to I from an input of at least a, keeping m in the Zener.

::: step
answer: z - 0.7

### What's its output voltage?
:::

::: step
answer: (a - z)/(m + I/(b + 1))

### What's the largest base resistor?
:::

::: step
answer: 0.02585/I + r*((a - z)/(m + I/(b + 1)))/(r + (a - z)/(m + I/(b + 1)))/(b + 1)

### What's its output resistance at full load, with $V_T$ = 25.85 mV?
:::

::: right
Right. The follower divides the reference's resistance by β + 1 and adds its own $r_e$.
:::
:::

::: explain
## Why does an emitter-follower regulator dissipate more in its pass transistor during a short circuit than at full load?

::: model
At full load the output sits at its regulated voltage, so the pass transistor drops only the difference between the input and the output, at the full load current. In a short, the output is pulled to ground, so the transistor has almost the entire input voltage across it. A current limit keeps the current near its limit value, which is usually somewhat above the full-load current, so the product of the larger voltage and a similar or larger current is a much larger dissipation. That's why short-circuit protection either needs a heat sink sized for it or a foldback limit that reduces the current as the output falls.
:::
:::

::: practice

::: check
given: VZ = 4.7 | 10; b = 40 | 150; IL = 0.3 | 1.5
answer: IL*1000/(b + 1)
unit: mA
tolerance: 0.5%

## A follower regulator ({VZ} V Zener, β = {b}) supplies {IL} A. Base current from the Zener's resistor?

::: misses
- [any] $\frac{I_L}{\beta + 1}$.
:::
:::

::: check
given: Vin = 10 | 20; Vout = 5 | 8; I = 0.2 | 1.2
answer: (Vin - Vout)*I
unit: W
tolerance: 0.5%

## {Vout} V at {I} A from {Vin} V. Pass transistor dissipation?

::: misses
- [any] $(V_\text{in} - V_\text{out})I$.
:::
:::

::: check
given: v = 0.6 | 0.7; I = 0.3 | 3
answer: v/I
unit: Ω
tolerance: 0.5%

## Limit at {I} A, sense transistor at {v} V. Sense resistor?

::: misses
- [any] $\frac{V_{BE}}{I_\text{lim}}$.
:::
:::
:::