C6 Electronics II: amplifiers, feedback and op-amps · Practice
Comparators, Schmitt triggers and relaxation oscillators
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A Schmitt trigger feeds back β = 0.2 of its ±5 V output. What's its upper threshold?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Same Schmitt trigger: β = 0.2, ±5 V. How wide is its hysteresis?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A relaxation oscillator has R = 47 kΩ, C = 10 nF and β = ½. What's its period?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A relaxation oscillator has R = 10 kΩ, C = 10 nF and β = 0.8. What's its period?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A ±12 V Schmitt trigger must reject 0.1 V of peak noise, with 10 kΩ to ground at its non-inverting input.
(a)
What β does it need?
(b)
What feedback resistor?
Write units the way you normally would: 1.5 kΩ, 1500 Ω and 0.0015 MΩ are the same answer.
Check
Relaxation oscillator with β = ½: R = 1 kΩ, C = 1 µF. Period (≈ 2.2RC)?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
Check
A divider of 10 kΩ (to ground) and 100 kΩ (to the output) feeds back what fraction β?
Check
An oscillator's period is 2 ms. Frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in C6