C623 of 57
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C6 · Lesson 23 · Fully differential amplifiers

Two outputs, a set common mode, and twice the swing

A precision converter doesn't measure one voltage against ground; it measures the difference between two inputs, each held near a common-mode voltage it specifies. A fully differential amplifier drives exactly that: two outputs that move in opposite directions around a common mode set by a separate pin. It doubles the signal swing available from a supply, cancels even-order distortion, and rejects noise that both wires pick up together.

Play

  • The two traces are a fully differential amplifier's outputs on a single 5 V supply; each can swing from 0.1 V to 4.9 V. The dashed one is their difference.
  • Their center is the output common-mode voltage, set independently of the signal. Move it off 2.5 V: one output reaches a rail before the other.
  • Raise the gain. The difference reaches nearly twice what either output can swing alone.

Predict

Each output of a fully differential amplifier on 5 V can swing from 0.1 V to 4.9 V. What's the largest differential output, peak to peak?

Name it

The fully differential amplifier

An FDA has two inputs and two outputs, plus a pin VOCM that sets the outputs' average. With equal resistors Rf and Rg on each side,

vod=vop−von=RfRgvid,vop+von2=VOCM.

An internal common-mode loop holds the output average at VOCM whatever the signal. Fed from one side only, with the other input resistor grounded (or at a bias), it converts a single-ended signal to a differential one.

Why differential

  • Swing: each output swings ±v^ about VOCM, so the difference swings ±2v^: twice the signal, 6 dB more.
  • Noise: the two outputs' independent noise adds in power, 2 times one, so the signal-to-noise ratio improves by 6 − 3 = 3 dB for the same per-output noise.
  • Distortion: even harmonics are the same on both outputs and cancel in the difference, to the degree the two halves match.
  • Interference coupled equally onto both wires is common mode and cancels.

Driving a converter

A differential converter specifies its input common mode (often half its reference) and full scale. Set VOCM to the common mode, choose the gain so full scale is reached at the outputs' allowed swing, and add a small RC at the converter's inputs to absorb its sampling kicks.

Worked example

A single-ended source swings 1 V peak around ground. An FDA must drive a converter whose full scale is ±2 V differential with its inputs centered at 1.65 V. What gain, VOCM and output voltages result?

Show the solution
  1. Gain. Full scale needs vod = ±2 V from ±1 V, a gain of 2: Rf=2Rg
  2. Common mode. Set VOCM = 1.65 V.
  3. Output voltages. At the positive peak the outputs sit at 1.65±1 V, 2.65 V and 0.65 V, so on a 3.3 V supply each output has 0.65 V to spare.
  4. Compare a single-ended stage. It would have needed to swing 4 V peak to peak around 1.65 V, which doesn't fit on 3.3 V at all.

Answer a gain of 2 (Rf=2Rg) with VOCM = 1.65 V, which puts the outputs at 2.65 V and 0.65 V at the peak.

Worked example

An amplifier's single-ended output has 10 µV RMS of noise and can swing 2 V peak. Built fully differentially, with the same noise on each output, how much better is its signal-to-noise ratio?

Show the solution
  1. Signal. It doubles, to 4 V peak: 20log10⁡2=6.0dB
  2. Noise. The noise of the two independent outputs adds as 102+102=14.1μV RMS which is 3.0 dB more.
  3. Net. The signal-to-noise ratio improves by 3.0 dB. That's why precision converters and their drivers are differential: the same supply and the same transistors buy 3 dB.

Answer the signal-to-noise ratio is 3.0 dB better.

Worked example

Each output of an FDA carries 1% second and 0.1% third harmonic, and its halves match to 5%. What harmonics does the differential output carry?

Show the solution
  1. Third harmonic. Like the signal, it's opposite on the two outputs, so it doubles along with the fundamental: still 0.1%.
  2. Second harmonic. It's the same on both outputs, so it cancels except for the 5% mismatch: 1%×0.05=0.05%
  3. Total harmonic distortion. It falls from 1+0.01 = 1.0% to 0.0025+0.01=0.11%

Answer the differential output carries 0.05% second and 0.1% third harmonic, 0.11% THD in all.

Check

A fully differential amplifier on 3.3 V with its outputs centered at mid-supply can bring each output within 0.05 V of the rails. What's its largest differential output, peak to peak?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A ±1 V single-ended signal must fill a converter's ±2 V differential full scale, centered at 1.65 V.

(a)

What gain does the FDA need?

(b)

What's the highest either output reaches?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A single-ended stage swings 1 V peak with 5 µV RMS of noise. A differential version has the same swing and noise on each output.

(a)

How much more signal does the differential version have?

(b)

How much better is its signal-to-noise ratio?

Check

Each output of an FDA has 1% second and 0.05% third harmonic, and its halves match to 10%.

(a)

What second harmonic does the differential output have?

(b)

What third harmonic?

Check

Interference couples 20 mV equally onto both wires feeding a fully differential amplifier. What does it do to the differential output?

Check

An FDA has Rf = f and Rg = g on each side, a differential input d and VOCM = c.

Step 1

What's the differential output?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a fully differential output get more signal out of the same supply than a single-ended one?

Practice

Keep practicing

6 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.