C6 · Lesson 23 · Fully differential amplifiers
Two outputs, a set common mode, and twice the swing
A precision converter doesn't measure one voltage against ground; it measures the difference between two inputs, each held near a common-mode voltage it specifies. A fully differential amplifier drives exactly that: two outputs that move in opposite directions around a common mode set by a separate pin. It doubles the signal swing available from a supply, cancels even-order distortion, and rejects noise that both wires pick up together.
Play
- The two traces are a fully differential amplifier's outputs on a single 5 V supply; each can swing from 0.1 V to 4.9 V. The dashed one is their difference.
- Their center is the output common-mode voltage, set independently of the signal. Move it off 2.5 V: one output reaches a rail before the other.
- Raise the gain. The difference reaches nearly twice what either output can swing alone.
Predict
Each output of a fully differential amplifier on 5 V can swing from 0.1 V to 4.9 V. What's the largest differential output, peak to peak?
9.6 V. When one output is at 4.9 V the other is at 0.1 V, a difference of +4.8 V; half a cycle later it's −4.8 V. A single-ended output on the same supply manages 4.8 V peak to peak, so the differential output has twice the swing.
Name it
The fully differential amplifier
An FDA has two inputs and two outputs, plus a pin that sets the outputs' average. With equal resistors and on each side,
An internal common-mode loop holds the output average at whatever the signal. Fed from one side only, with the other input resistor grounded (or at a bias), it converts a single-ended signal to a differential one.
Why differential
- Swing: each output swings about , so the difference swings : twice the signal, 6 dB more.
- Noise: the two outputs' independent noise adds in power, times one, so the signal-to-noise ratio improves by 6 − 3 = 3 dB for the same per-output noise.
- Distortion: even harmonics are the same on both outputs and cancel in the difference, to the degree the two halves match.
- Interference coupled equally onto both wires is common mode and cancels.
Driving a converter
A differential converter specifies its input common mode (often half its reference) and full scale. Set to the common mode, choose the gain so full scale is reached at the outputs' allowed swing, and add a small RC at the converter's inputs to absorb its sampling kicks.
Worked example
A single-ended source swings 1 V peak around ground. An FDA must drive a converter whose full scale is ±2 V differential with its inputs centered at 1.65 V. What gain, and output voltages result?
Show the solution
- Gain. Full scale needs = ±2 V from ±1 V, a gain of 2:
- Common mode. Set = 1.65 V.
- Output voltages. At the positive peak the outputs sit at V, 2.65 V and 0.65 V, so on a 3.3 V supply each output has 0.65 V to spare.
- Compare a single-ended stage. It would have needed to swing 4 V peak to peak around 1.65 V, which doesn't fit on 3.3 V at all.
Answer a gain of 2 () with = 1.65 V, which puts the outputs at 2.65 V and 0.65 V at the peak.
Worked example
An amplifier's single-ended output has 10 µV RMS of noise and can swing 2 V peak. Built fully differentially, with the same noise on each output, how much better is its signal-to-noise ratio?
Show the solution
- Signal. It doubles, to 4 V peak:
- Noise. The noise of the two independent outputs adds as which is 3.0 dB more.
- Net. The signal-to-noise ratio improves by 3.0 dB. That's why precision converters and their drivers are differential: the same supply and the same transistors buy 3 dB.
Answer the signal-to-noise ratio is 3.0 dB better.
Worked example
Each output of an FDA carries 1% second and 0.1% third harmonic, and its halves match to 5%. What harmonics does the differential output carry?
Show the solution
- Third harmonic. Like the signal, it's opposite on the two outputs, so it doubles along with the fundamental: still 0.1%.
- Second harmonic. It's the same on both outputs, so it cancels except for the 5% mismatch:
- Total harmonic distortion. It falls from = 1.0% to
Answer the differential output carries 0.05% second and 0.1% third harmonic, 0.11% THD in all.
Check
A fully differential amplifier on 3.3 V with its outputs centered at mid-supply can bring each output within 0.05 V of the rails. What's its largest differential output, peak to peak?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A ±1 V single-ended signal must fill a converter's ±2 V differential full scale, centered at 1.65 V.
(a)
What gain does the FDA need?
(b)
What's the highest either output reaches?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A single-ended stage swings 1 V peak with 5 µV RMS of noise. A differential version has the same swing and noise on each output.
(a)
How much more signal does the differential version have?
(b)
How much better is its signal-to-noise ratio?
Check
Each output of an FDA has 1% second and 0.05% third harmonic, and its halves match to 10%.
(a)
What second harmonic does the differential output have?
(b)
What third harmonic?
Check
Interference couples 20 mV equally onto both wires feeding a fully differential amplifier. What does it do to the differential output?
Check
An FDA has = f and = g on each side, a differential input d and = c.
Step 1
What's the differential output?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What's the positive output?
Step 3
And the negative one?
Explain why
Why does a fully differential output get more signal out of the same supply than a single-ended one?
A single-ended output can only swing between the two rails, so its signal is at most the supply voltage peak to peak. A differential output is the difference between two outputs that move in opposite directions. When one is near the top rail, the other is near the bottom, so the difference reaches nearly the whole supply in one direction, and half a cycle later nearly the whole supply in the other. The differential signal therefore spans about twice the supply peak to peak, twice what a single output can, while the common mode stays fixed at the middle.
Practice
Keep practicing
6 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.