C6 · Lesson 22 · Instrumentation amplifiers
Amplifying a millivolt difference sitting on volts of common mode
A strain-gauge bridge on 5 V puts out a millivolt or two, riding on 2.5 V that's common to both of its outputs. A thermocouple's few millivolts may share a cable with a volt of hum. The difference amplifier of lesson 19 can subtract the two, but it loads the source through its input resistors, and its rejection of the common part depends on four resistors matching to a fraction of a percent. The instrumentation amplifier fixes both: two followers with gain give a very high input resistance and amplify only the difference, and a difference stage after them strips off what's left of the common mode. One resistor sets the gain.
- A three-op-amp instrumentation amplifier. The inputs are 2.5 V ± 5 mV, in opposite phase: a 10 mV difference on 2.5 V of common mode.
- The first stage's outputs keep the 2.5 V but swing ±105 mV: the difference is amplified 21 times while the common mode passes at a gain of 1. The final output is just the difference, ±210 mV, centered on 0 V.
- Lower to raise the gain: one resistor sets it.
Predict
A difference amplifier with a gain of 10 uses 0.1% resistors. Roughly what is its worst-case common-mode rejection?
About 69 dB, a ratio of 2750: . Its rejection depends on the ratio being identical on both sides, and 0.1% mismatches let a little common mode through. An instrumentation amplifier with a first-stage gain of 100 in front of the same difference stage gains another factor of 100, about 40 dB.
Name it
The difference amplifier's limits
With in and in feedback on both sides, the output is only if the two ratios match exactly. With resistors of tolerance ε, the worst-case common-mode rejection is about
And its inputs draw current through , so a source with a few kilohms of resistance unbalances it further.
The three-op-amp instrumentation amplifier
First stage: two non-inverting amplifiers joined by a single . For a difference , carries , which also flows through both resistors, so the difference grows by . For a common-mode input nothing flows in , and both outputs simply follow: a common-mode gain of 1. The inputs are the op amps' non-inverting inputs: gigohms.
Second stage: a difference amplifier with gain removes the common mode.
Because the first stage amplifies only the difference, the CMRR of the whole amplifier is roughly the second stage's CMRR times the first stage's gain. Integrated versions trim their resistors with a laser and give 100 to 130 dB, with gain set by one external (for example ).
Bridges
A Wheatstone bridge of four equal resistors R on an excitation , one of which changes by ΔR, gives a differential output of about on a common mode of : exactly the job an instrumentation amplifier does.
Worked example
Choose for a gain of 1000 in an amplifier with , and find the output for a strain-gauge bridge on 5 V whose gauge changes by 0.1%.
Show the solution
- Gain resistor.
- Bridge output.
- Amplifier output.
Answer = 49.4 Ω, and the output is 1.25 V.
Worked example
Compare the CMRR of a gain-10 difference amplifier with 0.1% resistors against an instrumentation amplifier whose first stage has a gain of 100, followed by a unity-gain difference stage with the same resistors.
Show the solution
- Difference amplifier. or 68.8 dB.
- Unity-gain stage alone.
- With the first stage. It multiplies that by 100: 50,000, or 94 dB.
Answer the difference amplifier's CMRR is 2750 (68.8 dB), and the instrumentation amplifier's 50,000 (94 dB).
Worked example
A three-op-amp instrumentation amplifier on a single 5 V supply has a first-stage gain of 100. Its inputs sit at 2.5 V common mode. Where do the first stage's outputs go for a 20 mV differential input, and for 50 mV?
Show the solution
- At 20 mV. The first stage passes the common mode at unity gain and amplifies the difference by 100, split equally: Fine.
- At 50 mV. The outputs would need to reach 0 and 5 V, which no op amp output can, so the first stage clips even though the final output may look in range.
- Usable input range. An in-amp's usable input range depends on the common-mode voltage and the gain together; datasheets plot it as a hexagon for that reason.
Answer at 20 mV the first stage's outputs sit at 1.5 V and 3.5 V; at 50 mV they would need 0 and 5 V, so the first stage clips.
Check
A three-op-amp instrumentation amplifier has = 10 kΩ, = 0.5 kΩ, = 10 kΩ and = 20 kΩ. What is its gain?
Check
An instrumentation amplifier with = 24.7 kΩ and a unity-gain second stage must have gain 10. What ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A difference amplifier of gain 10 uses 0.01% resistors. Roughly what is its worst-case CMRR?
Check
A bridge of equal resistors on 5 V has one arm that changes by 0.05%. What differential output does it give?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
An instrumentation amplifier's first stage has differential gain 101. Its inputs are 1 V ± 2/2 mV. What is the upper first-stage output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An instrumentation amplifier's difference stage has a CMRR of 60 dB, and its first stage a differential gain of 10. What is the overall CMRR?
Check
A three-op-amp in-amp's first stage has a gain of 50. Its inputs sit at 1.5 V common mode with 40 mV between them.
(a)
Where does the higher first-stage output sit?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And the lower one?
Check
An in-amp's first stage has gain G and uses = R; its difference stage is unity gain with resistors matched to a fraction e.
Step 1
What gain resistor sets G?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What CMRR does the difference stage alone give?
Step 3
What's the whole amplifier's CMRR?
Explain why
Why does an instrumentation amplifier reject common-mode signals better than a single difference amplifier with the same resistors?
A difference amplifier's rejection is limited by how well its resistor ratios match: a small mismatch turns a fixed fraction of the common-mode voltage into output. An instrumentation amplifier's first stage amplifies the difference between its inputs by its full gain but passes the common mode at a gain of exactly one, since with equal inputs no current flows in the gain resistor. So by the time the signal reaches the difference stage, the wanted part has been multiplied while the common-mode part hasn't. The same resistor mismatch leaks the same common mode, but now it's that much smaller relative to the amplified signal.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.