C934 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

C9 · Lesson 34 · Block diagrams and feedback

Connecting systems, and what feeding the output back does

Real systems are built from blocks: a sensor, an amplifier, a motor, a controller. In the s-domain, connecting blocks is just algebra: blocks in a chain multiply, blocks side by side add. The most consequential connection is feedback, where the output is measured and subtracted from the input. It's how an op amp gets a precise gain from wildly variable transistors, how a thermostat holds a temperature, and how a rocket balances on its thrust. Feedback moves a system's poles, which means it can make a sluggish system fast, an unstable one stable, or, pushed too hard, a stable one ring.

  • A plant G(s)=K/(s(s+a)), like a motor's position, sits in a unity-feedback loop. The crosses are the open-loop poles and the line is the root locus: where the closed-loop poles go as the gain K rises.
  • The dots are the closed-loop poles at the current K. At low K they're real: a slow, smooth response. Past K=a2/4 they split into a complex pair and the response overshoots.
  • Raise K and the poles climb: faster, but less damped. The readouts give the natural frequency, damping ratio and step-response overshoot.

Predict

An unstable plant G(s)=1/(s−2) is put in a unity-feedback loop with a gain K in front. How large must K be for the loop to be stable?

Name it

Connecting blocks

ConnectionOverall transfer function
seriesH1(s)H2(s)
parallelH1(s)+H2(s)
negative feedback, forward G, feedback HG(s)1+G(s)H(s)

G(s)H(s) is the loop gain. Where it's large, the closed loop is about 1/H: set by the feedback path, which can be made of precise resistors, instead of by G.

What feedback buys

  • Insensitivity: a fractional change in G changes the closed-loop gain by only 1/(1+GH) of that fraction.
  • Speed: for G=K/(s+a) with unity feedback, the closed-loop pole moves from −a to −(a+K): faster by a factor 1+K/a, at a DC gain of K/(a+K).
  • Stabilization: G=K/(s−a) has a closed-loop pole at a−K, stable for K > a.

The price

Higher gain moves poles further, and not always leftward. With G=K/(s(s+a)) the closed loop is K/(s2+as+K), a second-order system with

ωn=K,ζ=a2K,overshoot=e−πζ/1−ζ2

so more gain means faster but more oscillatory. Plants with more poles can go unstable as K rises, which is where control design (S9) begins.

Worked example

An amplifier with open-loop gain 1000 uses feedback H = 0.01. What is its closed-loop gain, and what happens if the open-loop gain drops 20%?

Show the solution
  1. Closed-loop gain. G1+GH=10001+10=90.9 close to 1/H = 100.
  2. With G down 20%. G falls to 800: 800/9=88.9 a change of 2.2% for a 20% change in G.
  3. First-order estimate. 20%/(1+GH)=20%/11=1.8%

Answer the closed-loop gain is 90.9, and it falls only 2.2%, to 88.9, when the open-loop gain drops 20%.

Worked example

G=K/(s(s+4)) in unity feedback. Describe the step response at K = 16 and K = 100.

Show the solution
  1. Damping at K = 16. ωn=4ζ=4/8=0.5
  2. Overshoot at K = 16. e−π⋅0.5/0.75=16%
  3. K = 100. Here ωn=10 and ζ = 0.2, so the overshoot is 53%.
  4. Compare. Six times the gain: faster, but far more ringing.

Answer at K = 16 the response overshoots 16% (ζ = 0.5); at K = 100 it's faster but overshoots 53% (ζ = 0.2).

Worked example

A plant G=K/(s+1) is in unity feedback. Where is the closed-loop pole, and what is the steady-state error to a step, for K = 9?

Show the solution
  1. Closed loop. T=K/(s+1+K)
  2. Pole. It moves from −1 to −(1+K)=−10: ten times faster.
  3. Steady-state error. The DC gain is K/(1+K)=0.9 so the output settles at 90% of the command, an error of 1/(1 + K) = 10%.
  4. The promise of feedback. More gain means a faster loop and a smaller error, which is the basic promise of feedback; an integrator in the loop removes the error entirely.

Answer the closed-loop pole is at −10, and the steady-state error to a step is 10%.

Check

A forward gain of 1000 has feedback H = 0.1. What is the closed-loop gain?

Check

The forward gain 200 drifts by 30%. With feedback H = 0.05, by roughly how many percent does the closed-loop gain change?

Check

G(s)=9/(s+1) in unity feedback.

(a)

Where is the closed-loop pole?

(b)

What is the closed-loop DC gain?

Check

G(s)=K/(s−3) is unstable. Above what K does unity feedback make it stable?

Check

G(s)=25/(s(s+2)) in unity feedback.

(a)

What is the closed loop's natural frequency?

Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.

(b)

What is its damping ratio?

Check

A second-order closed loop has ζ = 0.4. What percent overshoot does its step response show?

Check

H1=2/(s+1) and H2=5/(s+10).

(a)

What is the DC gain of the two in series?

(b)

What is the DC gain of the two in parallel?

Check

An amplifier with forward gain 200 uses feedback H = 0.05.

(a)

What is the closed-loop gain?

(b)

By what factor does feedback shrink the effect of a change in G?

Check

G=K/(s(s+a)) with K = 25 and a = 2, in unity feedback.

(a)

What is ωn?

Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.

(b)

What is ζ?

Explain why

Why does a large loop gain make the closed-loop gain depend on the feedback network instead of the amplifier?

Practice

Keep practicing

12 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.