D113 of 6
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

D11 · Lesson 3 · Fiber optics

How a glass fiber traps light by total internal reflection, numerical aperture and the acceptance cone, multimode fibers and the modal dispersion that limits them, single-mode fibers and the V-number, chromatic dispersion, and the bit-rate–distance limits each sets

A strand of glass thinner than a hair carries most of the world's data, terabits per second across oceans, because light bouncing inside it can't get out. The core has a slightly higher refractive index than the cladding around it, so light striking the boundary at a shallow enough angle reflects totally (D8). What limits a fiber isn't how much light it loses, about 0.2 dB per kilometer at 1550 nm, but how it smears pulses: rays taking different paths, and colors traveling at different speeds, arrive at slightly different times, until neighboring bits run together.

  • How far a pulse spreads against distance, for a multimode step-index fiber (core index 1.48, relative index difference Δ) and for a single-mode fiber with chromatic dispersion D carrying a source of spectral width Δλ.
  • Modal spreading grows fast: rays at different angles travel different path lengths. Chromatic spreading in single-mode fiber is far smaller.
  • A rule of thumb: the bit rate must stay below about 1/(2Δt).

Predict

A step-index fiber has a core index of 1.48 and a cladding index of 1.46. What's its numerical aperture, and how wide is its acceptance cone?

Name it

Guiding light

Total internal reflection traps light in a core of index n1 surrounded by cladding of index n2<n1. Light from outside is accepted within a cone of half-angle sin−1⁡NA, where

NA=n12−n22≈n12Δ,Δ=n1−n2n1

Multimode fiber and modal dispersion

A core of 50 or 62.5 µm supports many paths (modes). The steepest ray travels farther than the axial one, and in a step-index fiber the arrival times spread by about

Δt≈Ln1Δc

tens of nanoseconds per kilometer. Graded-index cores, whose index falls toward the edge, speed up the outer rays and cut this a hundredfold; multimode fiber still serves only links of hundreds of meters at high rates.

Single-mode fiber

A core small enough carries only one mode, when the V-number V=2πaNA/λ (core radius a) is below 2.405. Without modal spreading, what's left is chromatic dispersion: the glass's index varies with wavelength, so a source of spectral width Δλ spreads by

Δt=|D|LΔλ

with D ≈ 17 ps/(nm·km) for standard fiber at 1550 nm and near zero at 1310 nm. Narrow-linewidth lasers (lesson 1), dispersion-compensating fiber and DSP keep long links open.

Worked example

How much does the step-index fiber (n₁ = 1.48, n₂ = 1.46) spread pulses per kilometer, and what bit rate does that allow?

Show the solution
  1. Relative index difference. Δ=0.021.48=0.0135
  2. Spread over a kilometer. Δt=Ln1Δc=1000×1.48Δ3×108s=66.7ns
  3. Bit rate. B≈12×66.7ns=7.5Mb/s over a kilometer.
  4. Compare a single-mode fiber. At 1550 nm with a 0.1 nm source, it spreads only 17×80×0.1=136ps over 80 km.

Answer 66.7 ns per kilometer, which allows about 7.5 Mb/s over a kilometer.

Worked example

A fiber has a 4.1 µm core radius and an NA of 0.12. Is it single-mode at 1310 nm? Below what wavelength does it carry more modes?

Show the solution
  1. V-number at 1310 nm. V=2π×4.1×0.121.31=2.36
  2. Compare with 2.405. 2.36 < 2.405, so the fiber is single-mode.
  3. Cutoff wavelength. Set V = 2.405 and solve for the wavelength: λc=2π×4.1×0.122.405μm=1.285μm Below that a second mode appears.

Answer it's single-mode at 1310 nm (V = 2.36), and carries more modes below 1.285 µm.

Worked example

Single-mode fiber loses 0.2 dB/km at 1550 nm. What fraction of the light survives 50 km?

Show the solution
  1. Total loss. 50×0.2=10dB
  2. Fraction that survives. 10−10/10=0.1 so 10% arrives.
  3. Compare copper. Copper coax at gigahertz frequencies would lose hundreds of decibels over the same distance, which is why every long link is optical.

Answer 10% of the light survives 50 km.

Check

A fiber's core index is 1.48 and its cladding index 1.47. What's its numerical aperture?

Check

A fiber has an NA of 0.2. What's the half-angle of its acceptance cone in air?

Check

A single-mode link of 10 km has dispersion 3 ps/(nm·km), carrying a source 1 nm wide. How far does a pulse spread?

Write units the way you normally would: 1.5 ps and 0.0015 ns are the same answer.

Check

A fiber has a 4.1 µm core radius and an NA of 0.1. What's its V-number at 1.55 µm?

Check

A step-index fiber has core index 1.48 and cladding 0.005 lower.

(a)

What is its numerical aperture?

(b)

How much modal spreading does it cause per kilometer?

Write units the way you normally would: 1.5 ns/km, 1500 ps/km and 0.0015 µs/km are the same answer.

Check

A fiber has a 4.1 µm core radius and NA 0.12, at 1.55 µm.

(a)

What is its V number?

(b)

Is it single-mode (1 for yes)?

Check

A fiber loses 0.35 dB/km over 5 km.

(a)

What is the total loss?

(b)

What share of the light arrives?

Explain why

Why does a single-mode fiber carry data so much farther than a multimode fiber?

Practice

Keep practicing

9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.