title: "Fiber optics: total internal reflection and dispersion"
heading: How a glass fiber traps light by total internal reflection, numerical aperture and the acceptance cone, multimode fibers and the modal dispersion that limits them, single-mode fibers and the V-number, chromatic dispersion, and the bit-rate–distance limits each sets
eyebrow: D11 · Lesson 3 · Fiber optics
xp: 40
---

::: hook
A strand of glass thinner than a hair carries most of the world's data, terabits per second across oceans, because light bouncing inside it can't get out. The core has a slightly higher refractive index than the cladding around it, so light striking the boundary at a shallow enough angle reflects totally (D8). What limits a fiber isn't how much light it loses, about 0.2 dB per kilometer at 1550 nm, but how it smears pulses: rays taking different paths, and colors traveling at different speeds, arrive at slightly different times, until neighboring bits run together.
:::

::: play
- How far a pulse spreads against distance, for a multimode step-index fiber (core index 1.48, relative index difference Δ) and for a single-mode fiber with chromatic dispersion D carrying a source of spectral width Δλ.
- Modal spreading grows fast: rays at different angles travel different path lengths. Chromatic spreading in single-mode fiber is far smaller.
- A rule of thumb: the bit rate must stay below about 1/(2Δt).
:::

```sim plot
view: graph
x: L = 0.1..100 log
y: t = 0.001..10000 log
slider: d = 0.001..0.02 step 0.0005 = 0.0135
slider: D = 1..20 step 0.5 = 17
slider: w = 0.01..2 = 0.1 log
plot: L*1000*1.48*d/0.299792458 | samples: 300 | label: multimode spread, ns (L in km)
plot: D*L*w/1000 | samples: 300 | color: ch3 | label: single-mode chromatic spread, ns
readout: multimode bit-rate limit over 1 km, Mb/s = 1000/(2*1000*1.48*d/0.299792458) | digits: 3
readout: single-mode spread over 80 km, ps = D*80*w | digits: 3
```

::: predict
## A step-index fiber has a core index of 1.48 and a cladding index of 1.46. What's its numerical aperture, and how wide is its acceptance cone?

- [ ] 0.02, ±1.1°
- [x] 0.24, about ±14°
- [ ] 0.48, about ±29°
- [ ] 1.46, ±90°

::: reveal
NA = $\sqrt{n_1^2 - n_2^2}$ = √(2.1904 − 2.1316) = 0.242, and light entering within $\sin^{-1}$ 0.242 = 14.0° of the axis is trapped. Inside, rays meeting the core-cladding boundary beyond the critical angle, $\sin^{-1}(1.46/1.48)$ = 80.6° from the normal, reflect totally.
:::
:::

::: nameit
## Guiding light

Total internal reflection traps light in a core of index $n_1$ surrounded by cladding of index $n_2 < n_1$. Light from outside is accepted within a cone of half-angle $\sin^{-1}NA$, where

$$NA = \sqrt{n_1^2 - n_2^2} \approx n_1\sqrt{2\Delta}, \qquad \Delta = \frac{n_1 - n_2}{n_1}$$

## Multimode fiber and modal dispersion

A core of 50 or 62.5 µm supports many paths (modes). The steepest ray travels farther than the axial one, and in a step-index fiber the arrival times spread by about

$$\Delta t \approx \frac{Ln_1\Delta}{c}$$

tens of nanoseconds per kilometer. Graded-index cores, whose index falls toward the edge, speed up the outer rays and cut this a hundredfold; multimode fiber still serves only links of hundreds of meters at high rates.

## Single-mode fiber

A core small enough carries only one mode, when the **V-number** $V = 2\pi a\,NA/\lambda$ (core radius a) is below 2.405. Without modal spreading, what's left is **chromatic dispersion**: the glass's index varies with wavelength, so a source of spectral width Δλ spreads by

$$\Delta t = |D|L\,\Delta\lambda$$

with D ≈ 17 ps/(nm·km) for standard fiber at 1550 nm and near zero at 1310 nm. Narrow-linewidth lasers (lesson 1), dispersion-compensating fiber and DSP keep long links open.
:::

::: example
## How much does the step-index fiber (n₁ = 1.48, n₂ = 1.46) spread pulses per kilometer, and what bit rate does that allow?

::: solution
1. **Relative index difference.**
   $$\begin{aligned} \Delta &= \frac{0.02}{1.48} \\ &= 0.0135 \end{aligned}$$
2. **Spread over a kilometer.**
   $$\begin{aligned} \Delta t &= \frac{Ln_1\Delta}{c} \\ &= \frac{1000 \times 1.48\,\Delta}{3 \times 10^8}\ \text{s} \\ &= 66.7\ \text{ns} \end{aligned}$$
3. **Bit rate.**
   $$\begin{aligned} B &\approx \frac{1}{2 \times 66.7\ \text{ns}} \\ &= 7.5\ \text{Mb/s} \end{aligned}$$
   over a kilometer.
4. **Compare a single-mode fiber.** At 1550 nm with a 0.1 nm source, it spreads only
   $$17 \times 80 \times 0.1 = 136\ \text{ps}$$
   over 80 km.

**Answer:** 66.7 ns per kilometer, which allows about 7.5 Mb/s over a kilometer.
:::
:::

::: example
## A fiber has a 4.1 µm core radius and an NA of 0.12. Is it single-mode at 1310 nm? Below what wavelength does it carry more modes?

::: solution
1. **V-number at 1310 nm.**
   $$\begin{aligned} V &= \frac{2\pi \times 4.1 \times 0.12}{1.31} \\ &= 2.36 \end{aligned}$$
2. **Compare with 2.405.** 2.36 < 2.405, so the fiber is single-mode.
3. **Cutoff wavelength.** Set V = 2.405 and solve for the wavelength:
   $$\begin{aligned} \lambda_c &= \frac{2\pi \times 4.1 \times 0.12}{2.405}\ \mu\text{m} \\ &= 1.285\ \mu\text{m} \end{aligned}$$
   Below that a second mode appears.

**Answer:** it's single-mode at 1310 nm (V = 2.36), and carries more modes below 1.285 µm.
:::
:::

::: example
## Single-mode fiber loses 0.2 dB/km at 1550 nm. What fraction of the light survives 50 km?

::: solution
1. **Total loss.**
   $$50 \times 0.2 = 10\ \text{dB}$$
2. **Fraction that survives.**
   $$10^{-10/10} = 0.1$$
   so 10% arrives.
3. **Compare copper.** Copper coax at gigahertz frequencies would lose hundreds of decibels over the same distance, which is why every long link is optical.

**Answer:** 10% of the light survives 50 km.
:::
:::

::: check
given: a = 1.46 | 1.48 | 1.5; b = 0.01 | 0.02; let c = a - b
answer: sqrt(a^2 - c^2)
tolerance: 0.5%

## A fiber's core index is {a} and its cladding index {c}. What's its numerical aperture?

::: right
Right. $\sqrt{n_1^2 - n_2^2}$ = {answer}.
:::

::: misses
- [a - c] Use the difference of the squares, under a square root.
- [any] Not yet. The NA formula.
:::
:::

::: check
given: N = 0.1 | 0.2 | 0.275
answer: asin(N)*180/pi
unit: °
tolerance: 0.5%

## A fiber has an NA of {N}. What's the half-angle of its acceptance cone in air?

::: right
Right. $\sin^{-1}NA$ = {answer}°.
:::

::: misses
- [any] Not yet. The acceptance angle.
:::
:::

::: check
given: D = 3 | 17; L = 10 | 80 | 500; w = 0.01 | 0.1 | 1
answer: D*L*w
unit: ps
tolerance: 0.5%

## A single-mode link of {L} km has dispersion {D} ps/(nm·km), carrying a source {w} nm wide. How far does a pulse spread?

::: right
Right. $|D|L\Delta\lambda$ = {answer} ps.
:::

::: misses
- [any] Not yet. Dispersion times length times spectral width.
:::
:::

::: check
given: a = 3 | 4.1 | 25; N = 0.1 | 0.2; w = 0.85 | 1.31 | 1.55
answer: 2*pi*a*N/w
tolerance: 0.5%

## A fiber has a {a} µm core radius and an NA of {N}. What's its V-number at {w} µm?

::: right
Right. $2\pi a\,NA/\lambda$ = {answer}.
:::

::: misses
- [pi*a*N/w] Use the radius with 2π, or the diameter with π.
- [any] Not yet. The V-number.
:::
:::

::: check
kind: parts
given: n1 = 1.46 | 1.48 | 1.5; d = 0.005 | 0.01 | 0.02

## A step-index fiber has core index {n1} and cladding {d} lower.

::: part
answer: sqrt(n1^2 - (n1 - d)^2)
tolerance: 0.5%

### What is its numerical aperture?

::: misses
- [any] $\sqrt{n_1^2 - n_2^2}$.
:::
:::

::: part
answer: 1000*n1*(d/n1)/2.998e8*1e9
unit: ns/km
tolerance: 0.5%

### How much modal spreading does it cause per kilometer?

::: misses
- [any] $Ln_1\Delta/c$ with $\Delta = (n_1 - n_2)/n_1$.
:::
:::
:::

::: check
kind: parts
given: a = 3 | 4.1 | 25; A = 0.12 | 0.2; L = 0.85 | 1.31 | 1.55

## A fiber has a {a} µm core radius and NA {A}, at {L} µm.

::: part
answer: 2*pi*a*A/L
tolerance: 0.5%

### What is its V number?

::: misses
- [any] $V = 2\pi aNA/\lambda$.
:::
:::

::: part
answer: step(2.405 - 2*pi*a*A/L)
tolerance: 0

### Is it single-mode (1 for yes)?

::: misses
- [any] V below 2.405.
:::
:::
:::

::: check
kind: parts
given: a = 0.2 | 0.35 | 2.5; L = 5 | 50 | 100

## A fiber loses {a} dB/km over {L} km.

::: part
answer: a*L
unit: dB
tolerance: 0.5%

### What is the total loss?

::: misses
- [any] Per km × length.
:::
:::

::: part
answer: 10^(-a*L/10)*100
unit: %
tolerance: 0.5%

### What share of the light arrives?

::: misses
- [any] $10^{-L/10}$.
:::
:::
:::

::: explain
## Why does a single-mode fiber carry data so much farther than a multimode fiber?

::: model
In a multimode fiber, light travels down the core along many different paths, from straight down the axis to steeply zigzagging between the walls, and the zigzag paths are longer, so parts of each pulse arrive at different times. That spreading grows with distance and soon blurs consecutive bits together, limiting fast multimode links to a few hundred meters. A single-mode fiber's core is so narrow that only one path can propagate, which eliminates that spreading entirely. What remains is chromatic dispersion from the source's small spread of wavelengths, which is hundreds of times smaller, so single-mode fiber can carry gigabits per second over tens of kilometers or more.
:::
:::

::: practice

::: check
given: N = 0.05 | 0.1 | 0.14 | 0.2 | 0.22 | 0.3 | 0.5
answer: asin(N)*180/pi
unit: °
tolerance: 0.5%

## Acceptance half-angle for NA {N}?

::: misses
- [any] $\sin^{-1}NA$.
:::
:::

::: check
given: D = 0.5 | 20; L = 1 | 1000; w = 0.001 | 5
answer: D*L*w
unit: ps
tolerance: 0.5%

## Chromatic spread: D = {D}, {L} km, Δλ = {w} nm?

::: misses
- [any] $|D|L\Delta\lambda$.
:::
:::
:::