D11 · Lesson 4 · Optical links
A fiber link from laser to photodiode, its power budget of launch power, fiber attenuation, connector and splice losses, margin and receiver sensitivity, the low-loss windows at 1310 and 1550 nm, optical amplifiers, and wavelength-division multiplexing that puts dozens of channels on one fiber
A fiber link's budget looks like a radio link's (D4, D9) without the spreading: light stays inside the glass, so the loss grows only linearly with distance, a few tenths of a decibel per kilometer. That's why an unamplified link can span 100 km, and with optical amplifiers every 80 km, an ocean. And because a fiber's useful band is thousands of gigahertz wide, it can carry many independent channels at once, each on its own wavelength, like radio stations sharing the air.
- Received power against fiber length for a 0 dBm laser, two connector pairs (four connectors at 0.5 dB), two splices at 0.1 dB and a fiber loss α in dB/km.
- The dashed line is the receiver's −28 dBm sensitivity plus a 3 dB margin. The link works up to where they cross.
- Standard fiber loses about 0.35 dB/km at 1310 nm and 0.2 dB/km at 1550 nm, where silica is clearest.
Predict
A 0 dBm laser feeds a receiver with −28 dBm sensitivity. The link has 2 dB of connector loss, 0.2 dB of splices and needs a 3 dB margin. How long can the fiber be at 1310 nm (0.35 dB/km)?
The budget is 0 − (−28) = 28 dB; connectors, splices and margin take 5.2 dB, leaving 22.8 dB for fiber: 22.8/0.35 = 65 km. At 1550 nm, with 0.2 dB/km, the same budget reaches 114 km.
Name it
The budget
in dBm, with the link working while exceeds the receiver's sensitivity (set by its noise, D9) plus a margin for aging and repairs, typically 3 dB. Dispersion (lesson 3) sets a second, independent limit on length at high bit rates.
The windows
Silica's loss is lowest near 1550 nm (about 0.2 dB/km), where the erbium-doped fiber amplifier also works, amplifying many channels at once with no electronics. 1310 nm, with near-zero dispersion, suits shorter links; 850 nm suits cheap multimode links.
Wavelength-division multiplexing
Each channel occupies its own wavelength, combined and separated by passive filters. A wavelength span Δλ corresponds to a frequency span
so the erbium C band, 1530 to 1565 nm, is about 4.4 THz: 87 channels on a 50 GHz grid, each carrying 100 Gb/s or more.
Worked example
How far can the link in the predict question reach at 1550 nm?
Show the solution
- Reach at 1550 nm. The 22.8 dB left for fiber, at 0.2 dB/km:
- More launch power. Raising the launch power to +5 dBm adds 5 dB, worth more, as long as dispersion and nonlinear effects allow.
Answer 114 km, or 25 km more with a +5 dBm launch.
Worked example
How much bandwidth is the 35 nm C band, and how many 100 Gb/s channels fit on a 50 GHz grid?
Show the solution
- Bandwidth of the C band.
- Channels on a 50 GHz grid.
- Capacity. on one fiber.
Answer 4.38 THz, with room for 87 channels at 50 GHz spacing: 8.7 Tb/s on one fiber.
Worked example
How many gigahertz is a 0.8 nm channel spacing at 1550 nm?
Show the solution
- Convert the spacing to frequency.
- The grid. That's the standard 100 GHz DWDM grid.
- Half the spacing. Halving the spacing to 0.4 nm gives the 50 GHz grid.
Answer 99.9 GHz, the standard 100 GHz DWDM grid.
Check
A 0 dBm laser feeds 80 km of fiber losing 0.2 dB/km, with 4 connectors at 0.5 dB each. What power arrives?
Check
A 0 dBm transmitter, a receiver needing −24 dBm, 3.5 dB of connector and splice loss and a 3 dB margin. How long can fiber losing 0.5 dB/km be?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
How many gigahertz does 4 nm of spectrum span at 1310 nm?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A WDM system has 9.37 THz of usable spectrum on a 50 GHz grid. How many channels fit?
Check
An optical link launches 0 dBm into fiber of 0.35 dB/km; the receiver needs −28 dBm, with 6 dB of margin and 2 dB of connector loss.
(a)
What fiber loss can it afford?
(b)
How far can it reach?
Write units the way you normally would: 1.5 km and 1500 m are the same answer.
Check
A WDM band is 35 nm wide around 1550 nm, with channels every 100 GHz.
(a)
How wide is it in frequency?
Write units the way you normally would: 1.5 THz, 1500 GHz and 0.0015 PHz are the same answer.
(b)
How many channels fit?
Check
Two WDM channels are 0.8 nm apart at 1310 nm.
(a)
How far apart are they in frequency?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
(b)
Roughly what symbol rate could each carry, at half the spacing?
Explain why
Why can a fiber link span 100 km without amplifiers when a radio link of similar power reaches much less far?
A radio signal spreads out in all directions, so the power reaching a receiver falls with the square of the distance even through perfect vacuum, and doubling the distance always costs 6 decibels. Light in a fiber is confined to the core and never spreads, so its only loss is absorption and scattering in the glass, which in modern fiber removes only a fifth of a decibel per kilometer at 1550 nanometers. Loss in decibels then grows only in proportion to distance, so a modest budget of 25 decibels covers more than 100 kilometers, and amplifiers placed every 80 kilometers or so can stretch that indefinitely.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.