D114 of 6
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

D11 · Lesson 4 · Optical links

A fiber link from laser to photodiode, its power budget of launch power, fiber attenuation, connector and splice losses, margin and receiver sensitivity, the low-loss windows at 1310 and 1550 nm, optical amplifiers, and wavelength-division multiplexing that puts dozens of channels on one fiber

A fiber link's budget looks like a radio link's (D4, D9) without the spreading: light stays inside the glass, so the loss grows only linearly with distance, a few tenths of a decibel per kilometer. That's why an unamplified link can span 100 km, and with optical amplifiers every 80 km, an ocean. And because a fiber's useful band is thousands of gigahertz wide, it can carry many independent channels at once, each on its own wavelength, like radio stations sharing the air.

  • Received power against fiber length for a 0 dBm laser, two connector pairs (four connectors at 0.5 dB), two splices at 0.1 dB and a fiber loss α in dB/km.
  • The dashed line is the receiver's −28 dBm sensitivity plus a 3 dB margin. The link works up to where they cross.
  • Standard fiber loses about 0.35 dB/km at 1310 nm and 0.2 dB/km at 1550 nm, where silica is clearest.

Predict

A 0 dBm laser feeds a receiver with −28 dBm sensitivity. The link has 2 dB of connector loss, 0.2 dB of splices and needs a 3 dB margin. How long can the fiber be at 1310 nm (0.35 dB/km)?

Name it

The budget

Prx=Ptx−αL−∑Lconnectors−∑Lsplices

in dBm, with the link working while Prx exceeds the receiver's sensitivity (set by its noise, D9) plus a margin for aging and repairs, typically 3 dB. Dispersion (lesson 3) sets a second, independent limit on length at high bit rates.

The windows

Silica's loss is lowest near 1550 nm (about 0.2 dB/km), where the erbium-doped fiber amplifier also works, amplifying many channels at once with no electronics. 1310 nm, with near-zero dispersion, suits shorter links; 850 nm suits cheap multimode links.

Wavelength-division multiplexing

Each channel occupies its own wavelength, combined and separated by passive filters. A wavelength span Δλ corresponds to a frequency span

Δν=cΔλλ2

so the erbium C band, 1530 to 1565 nm, is about 4.4 THz: 87 channels on a 50 GHz grid, each carrying 100 Gb/s or more.

Worked example

How far can the link in the predict question reach at 1550 nm?

Show the solution
  1. Reach at 1550 nm. The 22.8 dB left for fiber, at 0.2 dB/km: 22.8dB0.2dB/km=114km
  2. More launch power. Raising the launch power to +5 dBm adds 5 dB, worth 5dB0.2dB/km=25km more, as long as dispersion and nonlinear effects allow.

Answer 114 km, or 25 km more with a +5 dBm launch.

Worked example

How much bandwidth is the 35 nm C band, and how many 100 Gb/s channels fit on a 50 GHz grid?

Show the solution
  1. Bandwidth of the C band. Δν=cΔλλ2=3×108×35×10−9(1547.5×10−9)2Hz=4.38THz
  2. Channels on a 50 GHz grid. ⌊4.38THz50GHz⌋=87
  3. Capacity. 87×100Gb/s=8.7Tb/s on one fiber.

Answer 4.38 THz, with room for 87 channels at 50 GHz spacing: 8.7 Tb/s on one fiber.

Worked example

How many gigahertz is a 0.8 nm channel spacing at 1550 nm?

Show the solution
  1. Convert the spacing to frequency. Δν=cΔλλ2=3×108×0.8×10−9(1550×10−9)2Hz=99.9GHz
  2. The grid. That's the standard 100 GHz DWDM grid.
  3. Half the spacing. Halving the spacing to 0.4 nm gives the 50 GHz grid.

Answer 99.9 GHz, the standard 100 GHz DWDM grid.

Check

A 0 dBm laser feeds 80 km of fiber losing 0.2 dB/km, with 4 connectors at 0.5 dB each. What power arrives?

Check

A 0 dBm transmitter, a receiver needing −24 dBm, 3.5 dB of connector and splice loss and a 3 dB margin. How long can fiber losing 0.5 dB/km be?

Write units the way you normally would: 1.5 km and 1500 m are the same answer.

Check

How many gigahertz does 4 nm of spectrum span at 1310 nm?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

Check

A WDM system has 9.37 THz of usable spectrum on a 50 GHz grid. How many channels fit?

Check

An optical link launches 0 dBm into fiber of 0.35 dB/km; the receiver needs −28 dBm, with 6 dB of margin and 2 dB of connector loss.

(a)

What fiber loss can it afford?

(b)

How far can it reach?

Write units the way you normally would: 1.5 km and 1500 m are the same answer.

Check

A WDM band is 35 nm wide around 1550 nm, with channels every 100 GHz.

(a)

How wide is it in frequency?

Write units the way you normally would: 1.5 THz, 1500 GHz and 0.0015 PHz are the same answer.

(b)

How many channels fit?

Check

Two WDM channels are 0.8 nm apart at 1310 nm.

(a)

How far apart are they in frequency?

Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.

(b)

Roughly what symbol rate could each carry, at half the spacing?

Explain why

Why can a fiber link span 100 km without amplifiers when a radio link of similar power reaches much less far?

Practice

Keep practicing

9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.