D13 Final capstone · Practice
Motor controller: the H-bridge and PWM
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Check
A 24 V bridge switches a 2 mH winding at 40 kHz and duty 0.25. What's the peak-to-peak current ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 24 V bridge drives a motor at duty 0.75. The motor's back-EMF is 6 V and its winding resistance 2 Ω. What's the average current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 24 V bridge drives a 0.1 mH winding. What's the lowest switching frequency that keeps the worst-case ripple within 2 A peak to peak?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
An H-bridge switches 24 V at 40 kHz with duty 0.2 into a motor winding of 4 mH.
(a)
What is the peak-to-peak ripple current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the largest ripple at any duty?
Check
An H-bridge carries 5 A through two MOSFETs in series, each with 10 mΩ on-resistance. What conduction loss does that cause?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
An H-bridge leg has 200 ns of dead time at each of its two transitions per period, at 10 kHz. During dead time the output follows the load current's diode instead of the command. Up to what percentage of the period is the duty in error?
Check
Ripple: 5 V, D = 0.1, 10 mH, 100 kHz?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Minimum frequency: 6 V, 0.02 mH, 5 A ripple?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in D13