D2 · Lesson 7 · Motor drives and field-oriented control

Variable-frequency drives that set a motor's speed by its supply frequency, volts per hertz to hold the flux constant, constant torque below base speed and constant power above it, the fan laws that make drives save energy, and field-oriented control that splits current into flux and torque parts

For most of the twentieth century, an AC motor ran at one speed: the one its supply frequency set. A fan that needed less air was throttled with a damper while the motor ran flat out. The variable-frequency drive changed that. It rectifies the line to DC and inverts it back to AC at whatever frequency and voltage the motor needs (lesson 4), so the motor runs only as fast as the job requires. Add a fast processor that controls the current vector inside the motor, and an AC motor responds as crisply as any servo, which is how electric cars and modern robots drive their wheels and joints.

  • The torque a drive can deliver against speed. Below base speed the drive raises voltage with frequency, holding the flux, so the full rated torque is available. Above it the voltage is at its limit, so the flux, and the available torque, fall as 1/speed: constant power.
  • The dashed curve is a fan's load torque, which grows as the square of speed; the motor runs where the fan's demand meets the drive's setting.
  • The readouts give the rated power and the fan's power at a chosen fraction of base speed.

Predict

A fan's motor is slowed by a drive to 80% of its full speed. About how much of its full-speed power does the fan now draw?

Name it

Variable-frequency drives

A drive's speed command sets the inverter's output frequency, and the motor turns near n=120f/p (less slip for an induction motor). To keep the motor's flux, and so its torque per ampere, constant, the drive raises the voltage in proportion to the frequency: constant volts per hertz. A 460 V, 60 Hz motor gets 307 V at 40 Hz.

Base speed and field weakening

At base speed the drive reaches its maximum voltage. Above it the frequency can rise further but the voltage can't, so the flux falls as 1/f, and so does the available torque: the motor runs at constant power, which suits traction and spindles.

Fan and pump laws

Flow ∝ n, pressure ∝ n², power ∝ n³. A small speed reduction makes a large power saving.

Field-oriented control

A rotating field can be described in a frame that rotates with it (the dq frame of S12). There, the stator current splits into

  • id, along the rotor's flux, which sets the flux;
  • iq, at right angles, which makes torque.

Controlling id and iq separately with fast current loops makes an AC motor behave like a DC motor with a separate field. For a surface permanent-magnet motor with p poles and magnet flux linkage λ,

T=32⋅p2λiq

so torque is directly proportional to the q current, and id is kept at zero below base speed (made negative above it to weaken the field).

Worked example

A drive runs a 50 N·m, 1750 rpm motor. What's its rated power, and what torque is available at 3500 rpm?

Show the solution
  1. Rated power. P=50×1750×2π/60=9.16kW
  2. Torque at 3500 rpm. At twice base speed, constant power leaves 50×1750/3500=25N·m

Answer the rated power is 9.16 kW, and 25 N·m is available at 3500 rpm.

Worked example

An eight-pole PM motor has λ = 0.05 Wb and is driven with iq = 20 A, id = −5 A. What torque does it make, and what's the current magnitude?

Show the solution
  1. Torque. It's set by iq alone in a surface PM motor: T=1.5×4×0.05×20=6.0N·m
  2. Current magnitude. |I|=202+52=20.6A
  3. Why a negative id. It weakens the field to allow higher speed.

Answer the motor makes 6.0 N·m, and the current magnitude is 20.6 A.

Worked example

A four-pole motor slips 50 rpm at rated torque. A drive runs it at 30 Hz with the same torque. What speed results, and how does the slip compare?

Show the solution
  1. Synchronous speed at 30 Hz. 120×30/4=900rpm
  2. Speed. With constant V/f the slip in rpm stays about the same at the same torque, so the motor turns at 900−50=850rpm
  3. Slip compared. That's 5.6% slip against 2.8% at 60 Hz. Slip compensation in the drive raises the frequency slightly to make up for it.

Answer the motor turns at 850 rpm, a slip of 5.6% against 2.8% at 60 Hz.

Check

A 400 V, 50 Hz motor is run by a constant-V/f drive at 45 Hz. What voltage does the drive apply?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A 5 kW fan is slowed to 0.7 of its full speed. What power does it draw?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

Check

A drive delivers 50 N·m up to a base speed of 1500 rpm, then constant power. What torque is available at 4500 rpm?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

An 8-pole surface PM motor with λ = 0.02 Wb carries iq = 50 A. What torque does it make?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

Check

A 400 V, 50 Hz motor runs from a constant-V/f drive at 45 Hz.

(a)

What voltage does the drive apply?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

(b)

What ratio does it hold?

Check

A motor rated 50 N·m at 1450 rpm base speed runs in field weakening at 3 times base speed.

(a)

What torque is available there at constant power?

Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.

(b)

What is that constant power?

Explain why

Why does a constant-V/f drive raise the voltage in proportion to the frequency?

Practice

Keep practicing

9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.