title: Motor drives and field-oriented control
heading: Variable-frequency drives that set a motor's speed by its supply frequency, volts per hertz to hold the flux constant, constant torque below base speed and constant power above it, the fan laws that make drives save energy, and field-oriented control that splits current into flux and torque parts
eyebrow: D2 · Lesson 7 · Motor drives and field-oriented control
xp: 40
---

::: hook
For most of the twentieth century, an AC motor ran at one speed: the one its supply frequency set. A fan that needed less air was throttled with a damper while the motor ran flat out. The variable-frequency drive changed that. It rectifies the line to DC and inverts it back to AC at whatever frequency and voltage the motor needs (lesson 4), so the motor runs only as fast as the job requires. Add a fast processor that controls the current vector inside the motor, and an AC motor responds as crisply as any servo, which is how electric cars and modern robots drive their wheels and joints.
:::

::: play
- The torque a drive can deliver against speed. Below **base speed** the drive raises voltage with frequency, holding the flux, so the full rated torque is available. Above it the voltage is at its limit, so the flux, and the available torque, fall as 1/speed: constant power.
- The dashed curve is a fan's load torque, which grows as the square of speed; the motor runs where the fan's demand meets the drive's setting.
- The readouts give the rated power and the fan's power at a chosen fraction of base speed.
:::

```sim plot
view: graph
x: n = 10..5000
y: T = 0..80
slider: b = 1000..3600 step 50 = 1750
slider: R = 10..70 step 1 = 50
slider: k = 0.3..1 step 0.05 = 0.8
plot: (R + R*b/n - abs(R - R*b/n))/2 | samples: 400 | label: available torque, N·m (n in rpm)
plot: R*(n/b)^2 | samples: 400 | dashed | color: ch3 | label: fan load reaching rated torque at base speed
marker: n = k*b | label: running speed
readout: rated power, kW = R*b*2*pi/60/1000 | digits: 3
readout: fan power at the running speed, kW = R*k^2*k*b*2*pi/60/1000 | digits: 3
```

::: predict
## A fan's motor is slowed by a drive to 80% of its full speed. About how much of its full-speed power does the fan now draw?

- [ ] 80%
- [ ] 64%
- [x] About 51%
- [ ] 20%

::: reveal
A fan's airflow goes as speed, its pressure as speed squared, and its power as speed cubed: 0.8³ = 0.512. Slowing a 30 kW fan by 20% saves almost 15 kW, which is why drives on fans and pumps often pay for themselves in a year or two.
:::
:::

::: nameit
## Variable-frequency drives

A drive's speed command sets the inverter's output frequency, and the motor turns near $n = 120f/p$ (less slip for an induction motor). To keep the motor's flux, and so its torque per ampere, constant, the drive raises the voltage in proportion to the frequency: **constant volts per hertz**. A 460 V, 60 Hz motor gets 307 V at 40 Hz.

## Base speed and field weakening

At **base speed** the drive reaches its maximum voltage. Above it the frequency can rise further but the voltage can't, so the flux falls as 1/f, and so does the available torque: the motor runs at constant power, which suits traction and spindles.

## Fan and pump laws

Flow ∝ n, pressure ∝ n², power ∝ n³. A small speed reduction makes a large power saving.

## Field-oriented control

A rotating field can be described in a frame that rotates with it (the dq frame of S12). There, the stator current splits into

- $i_d$, along the rotor's flux, which sets the flux;
- $i_q$, at right angles, which makes torque.

Controlling $i_d$ and $i_q$ separately with fast current loops makes an AC motor behave like a DC motor with a separate field. For a surface permanent-magnet motor with p poles and magnet flux linkage $\lambda$,

$$T = \frac{3}{2}\cdot\frac{p}{2}\lambda i_q$$

so torque is directly proportional to the q current, and $i_d$ is kept at zero below base speed (made negative above it to weaken the field).
:::

::: example
## A drive runs a 50 N·m, 1750 rpm motor. What's its rated power, and what torque is available at 3500 rpm?

::: solution
1. **Rated power.**
   $$\begin{aligned} P &= 50 \times 1750 \times 2\pi/60 \\ &= 9.16\ \text{kW} \end{aligned}$$
2. **Torque at 3500 rpm.** At twice base speed, constant power leaves
   $$50 \times 1750/3500 = 25\ \text{N·m}$$

**Answer:** the rated power is 9.16 kW, and 25 N·m is available at 3500 rpm.
:::
:::

::: example
## An eight-pole PM motor has λ = 0.05 Wb and is driven with $i_q$ = 20 A, $i_d$ = −5 A. What torque does it make, and what's the current magnitude?

::: solution
1. **Torque.** It's set by $i_q$ alone in a surface PM motor:
   $$\begin{aligned} T &= 1.5 \times 4 \times 0.05 \times 20 \\ &= 6.0\ \text{N·m} \end{aligned}$$
2. **Current magnitude.**
   $$\begin{aligned} |I| &= \sqrt{20^2 + 5^2} \\ &= 20.6\ \text{A} \end{aligned}$$
3. **Why a negative $i_d$.** It weakens the field to allow higher speed.

**Answer:** the motor makes 6.0 N·m, and the current magnitude is 20.6 A.
:::
:::

::: example
## A four-pole motor slips 50 rpm at rated torque. A drive runs it at 30 Hz with the same torque. What speed results, and how does the slip compare?

::: solution
1. **Synchronous speed at 30 Hz.**
   $$120 \times 30/4 = 900\ \text{rpm}$$
2. **Speed.** With constant V/f the slip in rpm stays about the same at the same torque, so the motor turns at
   $$900 - 50 = 850\ \text{rpm}$$
3. **Slip compared.** That's 5.6% slip against 2.8% at 60 Hz. Slip compensation in the drive raises the frequency slightly to make up for it.

**Answer:** the motor turns at 850 rpm, a slip of 5.6% against 2.8% at 60 Hz.
:::
:::

::: check
given: V = 230 | 400 | 460; a = 50 | 60; f = 20 | 30 | 45
answer: V*f/a
unit: V
tolerance: 0.5%

## A {V} V, {a} Hz motor is run by a constant-V/f drive at {f} Hz. What voltage does the drive apply?

::: right
Right. $V_\text{rated}f/f_\text{rated}$ = {answer} V.
:::

::: misses
- [V] Holding full voltage at low frequency would saturate the motor.
- [any] Not yet. Voltage in proportion to frequency.
:::
:::

::: check
given: k = 0.5 | 0.7 | 0.9; P = 5 | 30 | 100
answer: P*k^3
unit: kW
tolerance: 0.5%

## A {P} kW fan is slowed to {k} of its full speed. What power does it draw?

::: right
Right. $P k^3$ = {answer} kW.
:::

::: misses
- [P*k] Fan power goes as the cube of speed.
- [P*k^2] That's how pressure scales; power goes as the cube.
- [any] Not yet. The fan laws.
:::
:::

::: check
given: T = 20 | 50 | 200; b = 1500 | 1750; n = 2500 | 3000 | 4500
answer: T*b/n
unit: N·m
tolerance: 0.5%

## A drive delivers {T} N·m up to a base speed of {b} rpm, then constant power. What torque is available at {n} rpm?

::: right
Right. $T_\text{rated}n_b/n$ = {answer} N·m.
:::

::: misses
- [T] Above base speed, the available torque falls.
- [any] Not yet. Constant power above base speed.
:::
:::

::: check
given: p = 4 | 8 | 10; l = 0.02 | 0.08; q = 10 | 50
answer: 1.5*p/2*l*q
unit: N·m
tolerance: 0.5%

## A {p}-pole surface PM motor with λ = {l} Wb carries $i_q$ = {q} A. What torque does it make?

::: right
Right. $\frac{3}{2}\cdot\frac{p}{2}\lambda i_q$ = {answer} N·m.
:::

::: misses
- [1.5*p*l*q] Use pole pairs, p/2.
- [any] Not yet. Torque from the q current.
:::
:::

::: check
kind: parts
given: V = 230 | 400 | 460; a = 50 | 60; f = 15 | 30 | 45

## A {V} V, {a} Hz motor runs from a constant-V/f drive at {f} Hz.

::: part
answer: V*f/a
unit: V
tolerance: 0.5%

### What voltage does the drive apply?

::: misses
- [any] $V \times f/f_\text{rated}$.
:::
:::

::: part
answer: V/a
unit: V/Hz
tolerance: 0.5%

### What ratio does it hold?

::: misses
- [any] Rated volts ÷ rated hertz.
:::
:::
:::

::: check
kind: parts
given: T = 20 | 50 | 120; n = 1450 | 1750; k = 1.5 | 2 | 3

## A motor rated {T} N·m at {n} rpm base speed runs in field weakening at {k} times base speed.

::: part
answer: T/k
unit: N·m
tolerance: 0.5%

### What torque is available there at constant power?

::: misses
- [any] Torque falls as 1/speed.
:::
:::

::: part
answer: T*n*2*pi/60/1000
unit: kW
tolerance: 0.5%

### What is that constant power?

::: misses
- [any] Rated torque × base speed in rad/s.
:::
:::
:::

::: explain
## Why does a constant-V/f drive raise the voltage in proportion to the frequency?

::: model
A motor's magnetic flux is set by the volt-seconds applied to its windings in each half cycle, which is the voltage divided by the frequency. If the drive lowered the frequency while keeping full voltage, each half cycle would last longer and drive the flux up into saturation, with huge magnetizing currents and heating. If it raised the frequency without raising the voltage, the flux would fall and so would the torque per ampere. Holding the ratio of voltage to frequency constant keeps the flux at its rated value, so the motor can produce its full torque at every speed up to the point where the drive runs out of voltage.
:::
:::

::: practice

::: check
given: k = 0.3 | 0.95; P = 0.5 | 500
answer: P*k^3
unit: kW
tolerance: 0.5%

## Fan power: {P} kW at {k} speed?

::: misses
- [any] $Pk^3$.
:::
:::

::: check
given: T = 5 | 500; b = 1000 | 3000; n = 3100 | 9000
answer: T*b/n
unit: N·m
tolerance: 0.5%

## Torque above base: {T} N·m to {b} rpm, now {n} rpm?

::: misses
- [any] $Tn_b/n$.
:::
:::

::: check
given: p = 2 | 4 | 6 | 8; l = 0.005 | 0.2; q = 1 | 300
answer: 1.5*p/2*l*q
unit: N·m
tolerance: 0.5%

## PM torque: {p} poles, λ = {l} Wb, $i_q$ = {q} A?

::: misses
- [any] $\frac{3}{2}\frac{p}{2}\lambda i_q$.
:::
:::
:::