D2 Power electronics and motor drives · Practice
Every topic, mixed
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Topics: all 9
Check
A linear regulator drops 12 V to 1.8 V at 2 A. How much power does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
What's the efficiency, in percent, of a linear regulator dropping 12 V to 1.8 V?
Check
A switching converter delivers 1.2 V at 3 A from a 12 V supply with efficiency 0.92. What current does it draw from the supply?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A linear regulator with = 80 °C/W drops 5 V to 3.3 V at 0.5 A in a 25 °C room. What's its junction temperature?
Check
A linear regulator drops 9 V to 1.8 V at 1 A, in a package with 60 °C/W, in a 25 °C room.
(a)
What does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
How hot is its junction?
Check
A switching converter makes 3.3 V at 3 A from 24 V at 92% efficiency.
(a)
What input current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What does it lose as heat?
Check
Linear dissipation: 3.3 V to 0.9 V at 5 A?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Switcher input current: 5 V in, 1 V and 50 A out, η = 0.97?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Linear efficiency, %: 3.3 V to 0.9 V?
Check
A buck converter makes 1.2 V from 12 V. What duty cycle does it need?
Check
A buck converter makes 3.3 V from 12 V with a 22 µH inductor at 1000 kHz. What's the peak-to-peak inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck converter's 0.5 A ripple current flows into a 100 µF capacitor at 200 kHz. What's the output ripple, ignoring its ESR?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
What inductance limits a 12 V to 3.3 V buck converter at 600 kHz to 0.6 A of ripple?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A buck converter makes 1.2 V from 12 V at 1000 kHz with a 22 µH inductor.
(a)
What is its duty cycle?
(b)
What is the inductor's peak-to-peak ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
Below what load does it enter discontinuous conduction?
Check
A buck makes 1.8 V from 5 V at 2000 kHz, and its ripple must be 0.4 A peak to peak.
(a)
What inductance does it need?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
And at twice the frequency?
Check
Duty: 3.6 V to 0.8 V?
Check
Ripple: 6 to 1 V, 100 µH, 2000 kHz?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Output ripple: 0.05 A, 100 kHz, 470 µF?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
An ideal boost converter runs from 5 V at duty cycle 0.3. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An ideal buck-boost converter runs from 5 V at duty cycle 0.25. What's its output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A lossless boost converter makes 12 V at 1 A from 3.3 V. What current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A boost converter's inductor resistance is 0.01 times its load resistance. What's the highest voltage ratio it can reach?
Check
A boost makes 15 V at 1 A from 5 V; its diode drops 0.5 V.
(a)
What duty cycle does it need?
(b)
Ignoring losses, what input current does it draw?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An ideal buck-boost makes −3 V from 12 V.
(a)
What duty cycle?
(b)
What voltage does the switch block when off?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Boost: 1 V at D = 0.1?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Buck-boost: 1 V at D = 0.1?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Boost duty for 1 V to 50 V?
Check
A bridge rectifier without a capacitor runs from 120 V RMS. What's the average of its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A full-wave rectifier on a 50 Hz line feeds 2 A from a 4700 µF capacitor. About how large is the ripple?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A six-pulse diode rectifier runs on a 400 V (line-to-line) three-phase supply. What's its average DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An H-bridge inverter with sinusoidal PWM runs from a 170 V bus at modulation index 0.6. What's the RMS of its fundamental output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A bridge rectifier on 120 V rms at 60 Hz feeds 0.5 A; the ripple must be under 10 V.
(a)
What capacitance does it need?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
What is the peak of the output, allowing 0.7 V for each of two diodes?
Check
A rectifier's 1000 µF capacitor at 160 V carries 2 A when its input fails; the load quits below 120 V.
(a)
How long is the hold-up?
Write units the way you normally would: 1.5 ms, 1500 µs and 0.0015 s are the same answer.
(b)
What energy does the capacitor give up?
Check
Rectified average from 24 V RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Ripple: 0.05 A, 50 Hz, 22000 µF?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
SPWM fundamental RMS: 100 V bus, m = 0.2?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 5 V PWM signal at duty cycle 0.15 goes through a slow low-pass filter. What DC voltage results?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 5 V PWM wave has duty cycle 0.1. What's the amplitude of its harmonic number 3?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 3.3 V PWM at 1 kHz and duty 0.2 feeds a 10 kΩ, 2.2 µF RC filter. About how much ripple is left, peak to peak?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
An LC filter with L = 1 mH and C = 1 µF follows a 100 kHz switching stage. By about how many decibels does it attenuate the switching frequency?
Check
An inverter's LC filter has L = 1 mH and C = 4.7 µF, switching at 40 kHz.
(a)
What is its corner frequency?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
(b)
Roughly how much does it attenuate the switching frequency?
Check
A 12 V PWM wave runs at 10% duty.
(a)
What is its DC term?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the amplitude of harmonic 3?
Check
PWM average: 1 V at D = 0.01?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Harmonic 3 of a 1 V PWM at D = 0.05?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
LC attenuation: 0.1 mH, 1 µF, 500 kHz?
Check
What's the synchronous speed of a 2-pole motor on a 50 Hz supply?
Check
A 4-pole induction motor on 50 Hz runs at a slip of 0.05. How fast does it turn?
Check
An induction motor on 50 Hz runs at a slip of 0.02. At what frequency do its rotor currents alternate?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A motor delivers 10 kW at 1450 rpm. What torque does it produce?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 4-pole induction motor on 50 Hz runs at 4% slip.
(a)
What is its synchronous speed?
(b)
What speed does it turn at?
(c)
What frequency do the rotor currents have?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A motor delivers 10 kW at 1450 rpm.
(a)
What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What torque would the same power give at twice the speed?
Check
Synchronous speed: 2 poles, 25 Hz?
Check
A motor's field turns at 1200 rpm and its rotor at 1188 rpm. What's the slip?
Check
Torque: 0.1 kW at 500 rpm?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 400 V, 50 Hz motor is run by a constant-V/f drive at 45 Hz. What voltage does the drive apply?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 5 kW fan is slowed to 0.7 of its full speed. What power does it draw?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A drive delivers 50 N·m up to a base speed of 1500 rpm, then constant power. What torque is available at 4500 rpm?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
An 8-pole surface PM motor with λ = 0.02 Wb carries = 50 A. What torque does it make?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A 400 V, 50 Hz motor runs from a constant-V/f drive at 45 Hz.
(a)
What voltage does the drive apply?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What ratio does it hold?
Check
A motor rated 50 N·m at 1450 rpm base speed runs in field weakening at 3 times base speed.
(a)
What torque is available there at constant power?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
(b)
What is that constant power?
Check
Fan power: 0.5 kW at 0.3 speed?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
Torque above base: 5 N·m to 1000 rpm, now 9000 rpm?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
PM torque: 4 poles, λ = 0.005 Wb, = 300 A?
Write units the way you normally would: 1.5 N·m, 1500 mN·m and 0.0015 kN·m are the same answer.
Check
A synchronous buck's two switches each have 2 mΩ of on-resistance and carry 10 A in turn. What's the total conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A switch turns 5 A on and off from 12 V with a combined rise and fall time of 50 ns at 500 kHz. Estimate its switching loss.
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A transistor dissipates 3 W with = 1 °C/W and = 0.8 °C/W in 50 °C air. What's the largest sink-to-air thermal resistance that keeps it under 150 °C?
Check
A buck converter's freewheeling diode drops 0.5 V at 5 A, with the switch on for a fraction 0.6 of each cycle. What does the diode dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A device dissipates 5 W with = 0.5 °C/W and = 0.5 °C/W, in 60 °C air, and must stay below 125 °C.
(a)
What heat sink rating does it need?
(b)
How hot would the junction be with an ideal (zero) heat sink?
Check
A buck makes 1.2 V at 10 A from 12 V. Its low-side switch is either a 0.5 V diode or a 20 mΩ MOSFET.
(a)
What does the diode lose?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What does the MOSFET lose?
Check
Switching loss: 5 V, 0.5 A, 200 ns, 2000 kHz?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Junction temperature: 0.5 W through 3 °C/W total, 20 °C air?
Check
Conduction loss: 0.5 A through 0.5 mΩ?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A buck MPPT charger feeds a 13.5 V battery from a panel whose maximum power point is at 30 V. What duty cycle holds the panel at its peak?
Check
An MPPT charger with efficiency 0.93 holds a panel at its 240 W peak while charging a 26 V battery. What's the charging current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A panel's maximum power point is 30 V at 7.2 A, its open-circuit voltage 37.5 V and short-circuit current 8.2 A. What's its fill factor?
Check
A panel's maximum power point is 31.6 V at 5 A; its open-circuit voltage is 44 V and short-circuit current 9.5 A. A buck charger feeds a 12.8 V battery.
(a)
What is the fill factor?
(b)
What duty cycle holds the panel at its peak?
Check
A 239 W panel gets 3 full-sun-equivalent hours a day; its MPPT charger is 96% efficient into a 13.5 V battery.
(a)
What energy reaches the battery each day?
Write units the way you normally would: 1.5 Wh, 1500 mWh and 0.0015 kWh are the same answer.
(b)
How many amp-hours is that?
Check
MPPT duty: 6 V battery, 60 V peak?
Check
Charge current: 10 W, η = 0.85, 48 V?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to D2