D3 Control systems · Practice
Digital control
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
0 solved
0 in a row
0 of 9 kinds solid
Check
A loop crosses over at 100 rad/s and is sampled every 0.5 ms. About how much phase does the zero-order hold cost at crossover?
Check
A continuous pole at s = −10 s⁻¹ is sampled every 1 ms. Where does it land in the z-plane?
Check
A sampled proportional loop around an integrator runs every 5 ms. Above what gain does it go unstable?
Check
A loop needs a closed-loop bandwidth of 20 Hz, and you want to sample 10 times faster than that. What sample rate do you need?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
A continuous pole at s = −50 is sampled every 1 ms.
(a)
Where does it map exactly?
(b)
Where does Tustin put it?
Check
A loop crossing over at 50 rad/s is sampled every 1 ms.
(a)
How much phase does the zero-order hold cost?
(b)
How many times the crossover is the sample rate (in rad/s)?
Check
z for s = −0.5 with T = 0.1 ms?
Check
Gain limit for a sampled integrator loop, T = 1 ms?
Check
Hold phase loss at 1 rad/s, T = 0.01 ms?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to the lesson · Practice every topic in D3