D8 · Lesson 12 · Input impedance and stubs
How a length of line transforms the load at its far end into a different impedance at its input, the impedance circle a load traces as the line grows, the quarter-wave line that inverts impedances and matches resistances, the half-wave line that repeats them, and shorted and open stubs as inductors and capacitors
At high frequencies a length of transmission line isn't just a connection: it's a component. Look into a 100 Ω load through an eighth of a wavelength of 50 Ω line and you see 40 − j30 Ω. Through a quarter wavelength you see 25 Ω, and through a half wavelength the original 100 Ω again. A shorted piece of line acts as an inductor or a capacitor depending on its length, with no lumped parts at all. Microwave engineers build filters, matching networks and resonators this way, and the same effect can wreck a design whose connections are longer than anyone thought.
- The input impedance of a 50 Ω line of electrical length βl ending in a load , drawn in the complex impedance plane.
- As the line lengthens, travels around a circle, returning to the load every half wavelength. A matched load (50 Ω) stays put.
- At a quarter wavelength the impedance is inverted: .
Predict
A 200 Ω load must be matched to a 50 Ω line with a quarter-wave section. What impedance should the section have?
A quarter wavelength of line with impedance turns a load into . For that to be 50 Ω with = 200 Ω, = 100 Ω. It works exactly only at the frequency where the section is a quarter wave long.
Name it
Input impedance
A load seen through a lossless line of impedance and length l:
Special lengths
- Half wave (βl = π): , whatever is.
- Quarter wave (βl = π/2): . A short becomes an open and vice versa, and a quarter-wave transformer of impedance matches two resistances.
Stubs
- A shorted stub: , inductive for lengths under λ/4 and capacitive between λ/4 and λ/2.
- An open stub: , capacitive for lengths under λ/4.
Placed in parallel with a line, stubs cancel unwanted reactance (lesson 14). The physical length of a quarter wave is , shortened by the line's velocity factor .
Worked example
What does a 100 Ω load look like through λ/8 of 50 Ω line? Through λ/4?
Show the solution
- Through λ/8. At βl = π/4, tan βl = 1:
- Through λ/4.
Answer the load looks like 40 − j30 Ω through λ/8, and 25 Ω through λ/4.
Worked example
How long is a quarter wave at 2.4 GHz in coax with a velocity factor of 0.66? What shorted 50 Ω stub gives +j30 Ω?
Show the solution
- Quarter wave in the coax.
- Stub angle. A shorted stub looks like , so
- Stub length.
Answer a quarter wave is 2.06 cm, and the stub is 0.0860 wavelengths long.
Worked example
A 100 Ω load sits at the end of 50 Ω line that is a half wavelength long at 1 GHz. What is the input impedance at 1 GHz and at 500 MHz?
Show the solution
- At 1 GHz. The line is λ/2 long, and a half-wave line repeats its load:
- At 500 MHz. It's λ/4 long and transforms the load:
- Across a band. The same line behaves very differently across a band.
Answer 100 Ω at 1 GHz and 25 Ω at 500 MHz.
Check
A 25 Ω load is seen through a quarter wavelength of 50 Ω line. What's the input impedance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What impedance should a quarter-wave transformer have to match a 10 Ω load to a 50 Ω line?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A shorted stub of 50 Ω line is 0.05 wavelengths long. What reactance does it present?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
How long is a quarter wavelength at 2.4 GHz on a line with a velocity factor of 0.66?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
A 100 Ω load is fed through a 50 Ω line.
(a)
What does it look like through λ/4?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
And through λ/2?
Check
A shorted stub of 50 Ω line must look like +j30 Ω at 2.4 GHz, in cable with velocity factor 0.8.
(a)
What electrical length does it need ()?
(b)
How long is it physically?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Explain why
Why does a quarter-wavelength line turn a short circuit into an open circuit?
A wave sent down a shorted line reflects with its voltage inverted, since the short forces zero voltage at the end. Over a quarter-wavelength line, the round trip to the short and back adds half a wavelength of delay, another inversion, so at the input the returning wave's voltage is back in phase with the outgoing one and adds to it while their currents cancel. Voltage with no current is exactly what an open circuit looks like. The same reasoning turns any load into its inverse about the line's impedance, which is why quarter-wave sections are used both as transformers and as resonant traps.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.