D8 · Lesson 8 · A line as an LC ladder
Why a long pair of wires can't be treated as a single node, chopping it into short sections of series inductance and shunt capacitance, the delay and characteristic impedance of each section, the cutoff frequency of a ladder, and how more and smaller sections converge on a smooth traveling wave
In circuit theory a wire is a node: the voltage at one end is the voltage at the other, instantly. That's only true while the wire is short compared with the time a signal takes to cross it. A 20 cm trace on a fast board takes a full nanosecond, during which a modern edge has come and gone. To model it, cut the line into short pieces. Each piece of wire has a little series inductance (its loop of current makes a magnetic field) and a little shunt capacitance to the return conductor (its charge makes an electric field). A ladder of such sections is a circuit you already know how to solve, and as the sections shrink it becomes a transmission line.
- A step driven through 50 Ω into a ladder of five LC sections (10 nH and 4 pF each), terminated in 50 Ω.
- The step arrives at the far end about 1 ns later, the ladder's delay, with some ringing: five sections are a coarse model, and its sharp edge contains frequencies above the ladder's cutoff.
- Change the load: at 50 Ω, the ladder's own impedance, the far end settles cleanly; mismatched, a reflection runs back and the ends ring before settling.
Predict
Each section has 10 nH and 4 pF. What impedance does the ladder present, and how long does each section delay a signal?
A long ladder of L and C looks like a resistance = √(10 nH/4 pF) = 50 Ω at frequencies well below its cutoff, and each section delays by = √(4 × 10⁻²⁰) = 0.2 ns. Five sections make a 1 ns line, like 20 cm of a line with 250 nH/m and 100 pF/m.
Name it
The ladder
A line with inductance L′ and capacitance C′ per meter, cut into sections of length Δz, becomes a ladder with and per section. At low frequencies each section delays the signal by , and the ladder's input looks like
independent of Δz. A load equal to absorbs everything the line delivers.
Cutoff
A ladder is a low-pass filter: it passes waves only up to
and below that its wave speed falls with frequency. Making the sections smaller raises the cutoff, so with enough sections the ladder becomes indistinguishable from a continuous line. A practical rule is sections shorter than a tenth of the shortest wavelength of interest.
Why it matters
Any connection longer than about a tenth of a wavelength, or whose delay is comparable to a signal's rise time, must be treated as a transmission line. Lesson 9 takes the limit Δz → 0.
Worked example
A 20 cm line has L′ = 250 nH/m and C′ = 100 pF/m. What are its impedance, speed and delay? How many sections model it up to 3 GHz?
Show the solution
- Impedance.
- Speed.
- Delay.
- Sections for 3 GHz. Each section is a tenth of a wavelength at 3 GHz (the wavelength there is 6.7 cm), so
Answer the line is 50 Ω, carries signals at 2 × 10⁸ m/s and delays them 1 ns; 30 sections model it up to 3 GHz.
Worked example
How does the cutoff of a 1 ns ladder grow with its number of sections?
Show the solution
- Cutoff in terms of N. Each section's delay is 1 ns/N, so
- Put in N.
- Speed at 1 GHz. At 1 GHz, five sections carry the wave at 92.5% of the true speed, fifty at 99.93%.
Answer the cutoff grows in proportion to the number of sections: 1.59 GHz with 5, 15.9 GHz with 50 and 159 GHz with 500.
Worked example
Each 1 cm section of a ladder has 2.5 nH and 1 pF. What are its delay and impedance?
Show the solution
- Delay per section.
- Impedance.
- A delay line. Forty sections make a 2 ns delay line, valid only well below the ladder's cutoff, where each section is a small fraction of a wavelength.
Answer each section delays the signal 50 ps, and the ladder's impedance is 50 Ω.
Check
A ladder's sections each have 10 nH and 2 pF. What's its characteristic impedance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A ladder of 20 sections, each 10 nH and 2 pF, carries a slow signal. How long does it delay it?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
What's the cutoff frequency of a ladder whose sections each have 10 nH and 2 pF?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A line has a delay of 0.5 ns. How many sections keep each one under a tenth of a wavelength at 3 GHz?
Check
Each section of an LC ladder has 2.5 nH and 0.4 pF.
(a)
What is its characteristic impedance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What delay does each section add?
Check
A 2 ns delay line is modeled by 5 LC sections.
(a)
What is the ladder's cutoff, ?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
(b)
Up to about what frequency is it a good model, at a tenth of cutoff?
Explain why
Why does a ladder of small inductors and capacitors act like a transmission line only at low frequencies?
Each section stores energy in its inductor and capacitor and passes it on to the next after a short delay, so a disturbance travels down the ladder section by section like a wave, at a speed set by the inductance and capacitance per section. As long as the signal changes slowly compared with that section delay, many sections share each wavelength, and the steps blur into a smooth line. At frequencies approaching the cutoff, a wavelength spans only a couple of sections, the lumpiness matters, the wave slows and finally can't propagate at all. Making the sections smaller and more numerous pushes the cutoff up, and in the limit the ladder becomes the continuous line described by the telegrapher's equations.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.