D8 · Lesson 15 · Lossy lines and dispersion
Where a real line's loss comes from, conductor loss growing as the square root of frequency from the skin effect and dielectric loss growing in proportion to it, attenuation in decibels per meter and what it does to a link, dispersion that smears fast edges, and Heaviside's distortionless line
A 30 m run of thin coax that works fine at 100 MHz can swallow most of a 5 GHz signal. Every real line loses energy in two ways: its conductors have resistance, which the skin effect (lesson 5) raises as the square root of frequency, and its dielectric absorbs a little energy every cycle, in proportion to frequency. Loss that depends on frequency also distorts: it rounds off the sharp edges of digital signals more than their slow parts, which is the main reason a 10 Gb/s link needs equalization while a 100 Mb/s link doesn't.
- The attenuation of a line against frequency, from conductor loss (a in dB/m at 1 GHz) and dielectric loss for a material with = 4.4 and loss tangent tan δ.
- At low frequencies the conductors dominate; at high frequencies the dielectric does, since it grows faster.
- The readouts give the loss at 1 GHz and 10 GHz.
Predict
A coax loses 0.16 dB/m at 100 MHz, all from its conductors. About how much does it lose at 1 GHz?
Conductor loss follows the surface resistance, which grows as : ten times the frequency gives √10 = 3.16 times the loss, 0.51 dB/m. In practice the dielectric adds a little more at the higher frequency. A 30 m run then loses 15 dB at 1 GHz against 4.8 dB at 100 MHz.
Name it
Two kinds of loss
For a low-loss line, :
- Conductor loss , with R′ set by the surface resistance spread around the conductors' perimeters: it grows as , and fatter conductors lose less.
- Dielectric loss for a line filled with one material:
with the free-space wavelength, so it grows in proportion to f and depends only on the material.
What loss costs
Loss in decibels adds up along the line: L dB/m over d meters is Ld dB, leaving of the power. It also adds noise at the receiver and reduces how far a reflection's VSWR is seen at the source (a lossy line makes any load look better matched).
Dispersion
Because α and the phase velocity vary with frequency, a pulse's spectral components arrive with different sizes and delays, and its edges smear: dispersion. Fast serial links equalize it with filters that boost high frequencies before or after the line.
The distortionless line
Heaviside showed that if
the attenuation and the velocity are both independent of frequency, so pulses shrink without changing shape. Telephone cables had too little inductance for this, so loading coils were added every mile or two to raise L′.
Worked example
What dielectric loss does FR4 ( = 4.4, tan δ = 0.02) give at 1 GHz? How much power survives 6 dB of loss?
Show the solution
- Dielectric loss. That matches lesson 5's figure.
- Power left after 6 dB.
Answer FR4 loses 3.82 dB/m at 1 GHz, and 6 dB of loss leaves 25% of the power.
Worked example
A line has R′ = 0.5 Ω/m, L′ = 250 nH/m and C′ = 100 pF/m. What G′ makes it distortionless?
Show the solution
- Distortionless condition.
- The cost. Adding leakage on purpose costs more loss, which is why loading coils (raising L′) were the practical route.
Answer G′ = 200 µS/m.
Worked example
A 20 m run of coax loses 0.5 dB/m at 1 GHz. What fraction of the transmitter's power reaches the antenna?
Show the solution
- Total loss.
- Fraction arriving.
- What engineers do about it. That's why base stations mount amplifiers at the top of the tower, and why low-loss cable is thick.
Answer only 10% of the transmitter's power reaches the antenna.
Check
A line's conductor loss is 0.16 dB/m at 0.1 GHz. What is it at 10 GHz?
Check
A line filled with a dielectric of = 3.5 and loss tangent 0.0002 carries 10 GHz. What's its dielectric loss?
Check
A cable loses 0.5 dB/m. What percentage of the power survives 2 m of it?
Check
A line has R′ = 0.5 Ω/m, L′ = 250 nH/m and C′ = 100 pF/m. What shunt conductance would make it distortionless?
Write units the way you normally would: 1.5 µS/m, 1500 nS/m and 0.0015 mS/m are the same answer.
Check
A board material has = 3.5 and loss tangent 0.002, at 5 GHz.
(a)
What dielectric loss does a line in it have, ?
(b)
Over 10 cm?
Check
A cable loses 0.5 dB per meter and runs 5 m.
(a)
What is its total loss?
(b)
What share of the power arrives?
Explain why
Why does a fast digital signal suffer more from a lossy line than a slow one?
A digital signal's edges are made of high-frequency components, and the faster the data rate, the higher those components reach. A real line's loss grows with frequency, as the square root of frequency from the conductors' skin effect and in proportion to frequency from the dielectric, so it attenuates the high-frequency content that forms the sharp edges much more than the low-frequency content that forms the long flat parts of the waveform. The edges come out rounded and slow, and pulses smear into their neighbors, closing the eye of the received signal. Equalizers restore the balance by boosting the high frequencies the line removed.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.