D8 · Lesson 16 · Waveguides and cavities
Guiding microwaves down a hollow metal pipe, the modes that fit across it and their cutoff frequencies, the single-mode band of a rectangular guide, guide wavelength and the phase and group velocities on either side of the speed of light, and closing the guide into a resonant cavity
Above about 10 GHz, coaxial cable gets lossy and can't handle much power, so radar transmitters and satellite ground stations send their signals down hollow rectangular metal pipes instead. A waveguide has no center conductor, so it can't carry DC or low frequencies at all: a wave fits inside only if its half wavelength is shorter than the pipe is wide. Above that cutoff it travels with very low loss. Close the pipe's ends and the trapped waves resonate at exact frequencies, the basis of microwave filters, oscillators and the magnetron in every microwave oven.
- The phase velocity (solid) and group velocity (dashed) of the dominant TE₁₀ mode in a rectangular guide of width a, as fractions of the speed of light, against frequency.
- Below cutoff, , no wave propagates. Just above it the energy crawls along (group velocity near zero) while the phase races ahead; far above, both approach c.
- Their product is always .
Predict
A WR-90 waveguide is 22.86 mm wide. What's the lowest frequency it can carry?
The TE₁₀ mode fits half a wavelength across the guide's width, so it propagates only above = 299.8/(2 × 22.86 mm) = 6.56 GHz. The next mode, TE₂₀, starts at 13.1 GHz, so the guide is used between about 8.2 and 12.4 GHz, safely in its single-mode range: the X band.
Name it
Modes
Inside a hollow conductor, the fields must meet the boundary conditions of lesson 3 on every wall, which allows only certain patterns, modes. In a rectangular guide of width a and height b, the transverse-electric modes have cutoffs
The dominant TE₁₀ mode has , with its electric field across the narrow dimension, largest in the middle. With b ≈ a/2, the next modes (TE₂₀ at and TE₀₁ at ) start near twice the cutoff, giving almost an octave of single-mode operation.
Propagation
Above cutoff the mode propagates with
so the guide wavelength is longer than in free space. The phase velocity exceeds c, while the energy travels at the group velocity , always less; their product is . Below cutoff, the fields decay exponentially along the guide.
Cavities
Closing a guide with metal walls at both ends traps standing waves. A rectangular cavity of width a and length d resonates in its TE₁₀₁ mode at
with Q factors of thousands to tens of thousands, far beyond lumped LC circuits.
Worked example
In WR-90 at 10 GHz, find the guide wavelength and the group velocity.
Show the solution
- Cutoff ratio.
- Guide wavelength.
- Group velocity.
- Phase velocity.
Answer the guide wavelength is 3.97 cm, and the group velocity is 0.755c (the phase velocity is 1.32c).
Worked example
A WR-90 cavity is closed off 30 mm long. Where's its lowest resonance? Where do WR-90's TE₂₀ and TE₀₁ modes start?
Show the solution
- Lowest resonance, TE₁₀₁. With a = 22.86 mm and d = 30 mm:
- TE₂₀ cutoff.
- TE₀₁ cutoff. With b = 10.16 mm,
Answer the cavity's lowest resonance is 8.24 GHz; TE₂₀ starts at 13.1 GHz and TE₀₁ at 14.8 GHz.
Worked example
WR-90 (cutoff 6.56 GHz) is fed at 5 GHz, below cutoff. How fast does the field die away along it?
Show the solution
- Attenuation. Below cutoff the mode is evanescent:
- In decibels.
- Where this is used. A few centimeters of guide below cutoff makes an excellent precision attenuator, and the honeycomb vents in shielded rooms work the same way.
Answer the field dies away at 88.9 Np/m, or 7.7 dB per centimeter.
Check
A rectangular waveguide is 22.86 mm wide. What's its TE₁₀ cutoff frequency?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A waveguide's cutoff is 6.56 GHz. What's its guide wavelength at 10 GHz?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Check
What fraction of the speed of light does energy travel at in a guide with cutoff 6.56 GHz, at 10 GHz?
Check
A rectangular cavity is 22.86 mm wide and 20 mm long. What's its TE₁₀₁ resonant frequency?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
Check
A rectangular waveguide is 22.86 mm wide and runs at 1.25 times its TE₁₀ cutoff.
(a)
What is the cutoff?
Write units the way you normally would: 1.5 GHz, 1500 MHz and 0.0015 THz are the same answer.
(b)
How many times the free-space wavelength is the guide wavelength?
Check
A waveguide with cutoff 6.56 GHz is fed at 0.5 times its cutoff, below it.
(a)
How fast does the evanescent field decay?
(b)
What length gives 60 dB of attenuation?
Write units the way you normally would: 1.5 cm, 15 mm and 0.015 m are the same answer.
Explain why
Why can't a hollow waveguide carry low frequencies?
A hollow metal pipe has only one conductor, so it can't carry a voltage between two conductors the way coax does, and with it goes the ability to carry DC or slowly varying signals. Instead, waves travel inside by bouncing between the walls, and the boundary conditions require the electric field along each wall to vanish, so across the guide the field must form a standing pattern that fits at least half a wavelength between the side walls. At low frequencies the half wavelength is wider than the guide, no such pattern fits, and the fields just decay along the pipe. Above the cutoff, the wave zigzags down the guide, and the steeper its zigzag near cutoff, the slower its energy moves along it.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.