D9 · Lesson 4 · Matching networks in practice
Matching a complex load such as a transistor's input, cancelling its reactance and then transforming its resistance, combining the steps into a two-element network, the loss that real inductors add, and trading bandwidth for selectivity with pi and multi-section networks
D8 matched a pure resistance. Real loads are rarely so polite: a transistor's input at 900 MHz might be 10 − j15 Ω, an antenna off resonance has reactance, and every component has loss. A practical matching network has to cancel the load's reactance, transform its resistance, and do it with parts that lose a little power and have a limited Q. The Smith chart still makes it a matter of two moves, and the engineering is in picking which two.
- A load of 10 − j15 Ω at 900 MHz (a transistor's input, say), a series inductor L next to it, and a shunt capacitor C across the 50 Ω line.
- The inductor first cancels the load's −j15 Ω and then adds the +j20 Ω the L-network needs; the capacitor then pulls the impedance onto the center of the chart.
- With L = 6.19 nH and C = 7.07 pF the input is 50 Ω. The readout gives |Γ|.
Predict
The load is 10 − j15 Ω. What series reactance would cancel its reactive part, and what inductance is that at 900 MHz?
A series +j15 Ω cancels the −j15 Ω, leaving 10 Ω, and L = 15/(2π × 900 MHz) = 2.65 nH. Matching 10 Ω to 50 Ω then needs another +j20 Ω in series (Q = 2) and a 25 Ω shunt capacitor, so the two series reactances combine into one 6.19 nH inductor.
Name it
Complex loads
To match to :
- Find the L-network for alone: , series , shunt .
- Absorb the load's reactance into the series element: it becomes .
The result is still two components. (For , the shunt element sits across the load instead, and it's the load's susceptance that gets absorbed.)
Real components
An inductor of quality factor has a series resistance . In series with a low-resistance load, it steals a fraction of the power:
Chip inductors at 1 GHz have of 20 to 60; capacitors are usually much better. Low-resistance loads, like power transistors, make matching losses grow.
Bandwidth and topology
An L-network's Q is fixed by the resistance ratio, and its bandwidth is roughly . A pi or T network adds a third element to choose a higher Q, for more filtering of harmonics; a cascade of L-networks through intermediate resistances lowers each step's Q, for wider bandwidth. Matching transistors also involves trading gain against noise and stability (S6).
Worked example
Design the match for 10 − j15 Ω at 900 MHz, and estimate the loss if the inductor's Q is 30.
Show the solution
- Q and the two reactances.
- Series inductor. It supplies plus the 15 Ω it must cancel:
- Shunt capacitor. It supplies 25 Ω:
- Inductor loss. Its resistance sits in series with the 10 Ω load:
Answer a 6.19 nH series inductor and a 7.07 pF shunt capacitor; the inductor's loss costs 0.48 dB.
Worked example
What's that network's approximate bandwidth?
Show the solution
- Bandwidth from Q. Its loaded Q is about 2, so plenty for a narrowband radio.
- The load's reactance. The load's own reactance changes with frequency too, so the true band is somewhat narrower.
Answer about 450 MHz, somewhat narrower in practice.
Worked example
Without its matching network, how much power would the 10 − j15 Ω load lose to mismatch on a 50 Ω line?
Show the solution
- Reflected fraction.
- Mismatch loss. Only 52% of the power is accepted:
- What the network recovers. The matching network, even with its inductor's loss, recovers most of that.
Answer only 52% of the power is accepted, a mismatch loss of 2.8 dB.
Check
A load of 10 + j(−30) Ω is matched to 75 Ω with a series element next to the load and a shunt element across the line. What series reactance is needed?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What inductance supplies 35 Ω of reactance at 0.9 GHz?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Check
A series inductor of 20 Ω reactance and Q = 40 feeds a 10 Ω load. How many decibels does its resistance cost?
Check
A 10 + j(−30) Ω load sits directly on a 50 Ω line.
(a)
What fraction of the power reflects?
(b)
What is the mismatch loss?
Check
An L-network raises 10 Ω to 50 Ω at 0.9 GHz with a series inductor and a shunt capacitor.
(a)
What is its Q?
(b)
What inductance (series reactance )?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Check
An L-network matches a 50 Ω source to a 300 Ω load at 100 MHz, with a series inductor on the 50 Ω side and a shunt capacitor across the load.
(a)
What is the network's Q?
(b)
What inductance does the series arm need?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Explain why
Why do matching losses get worse for low-resistance loads?
A practical inductor behaves as an ideal inductance in series with a small resistance, its reactance divided by its quality factor. In a matching network that resistance sits in series with the load, so the current that delivers power to the load also heats the inductor, and the fraction of power wasted is the inductor's resistance compared with the load's. A low-resistance load, like a power transistor's few ohms, needs the same or more reactance to transform it, so its inductor's loss resistance is a larger fraction of the load, and more of the power is lost. That's why high-power amplifiers use high-Q components or transmission-line matching.
Practice
Keep practicing
8 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.