title: Device reliability
heading: Arrhenius acceleration, electromigration, oxide wear-out and failure statistics
eyebrow: S1 · Lesson 46 · Device reliability
xp: 50
---

::: hook
A chip that works on the day it's made must keep working for ten years or more, and nobody can wait ten years to find out. Reliability engineering runs devices hot and hard, measures how fast they wear out, and uses physics to scale the result back to normal conditions. The mechanisms are the device physics of this course pushed to extremes: atoms in wires pushed along by the electron wind, oxides that slowly break down under field, interface traps generated by hot carriers and bias. Each has an acceleration law, and each law turns a thousand-hour test into a lifetime prediction.
:::

::: play
- The curve is the Arrhenius acceleration factor of a stress test at temperature $T_s$ against normal use at 55 °C, for a failure mechanism of activation energy $E_a$, on a log scale.
- A 0.7 eV mechanism tested at 125 °C ages about 78 times faster than in use: 1000 hours of testing stands for nearly nine years.
- Raise $E_a$ and the same oven gives more acceleration, but only if the mechanism really has that activation energy; guessing too high makes a product look more reliable than it is.
:::

```sim plot
view: graph
x: T = 60..175 °C
y: A = 1..100000 log
slider: E = 0.3..1.2 step 0.05 = 0.7 eV
plot: exp(E/8.617e-5*(1/328.15 - 1/(T + 273.15))) | label: acceleration
readout: acceleration at 125 °C = exp(E/8.617e-5*(1/328.15 - 1/398.15)) | digits: 4
```

::: predict
## A copper interconnect's current density is doubled. Under Black's equation with n = 2, what happens to its electromigration lifetime?

- [ ] It halves
- [x] It falls to a quarter
- [ ] It falls to an eighth
- [ ] Nothing, if the temperature stays the same

::: reveal
Black's equation, $\text{MTTF} \propto J^{-n}e^{E_a/kT}$, with n = 2 gives a quarter of the life. And more current usually means more Joule heating too, which shortens it further through the exponential. Layout tools check every wire's current density against a rule derived from exactly this.
:::
:::

::: nameit
## Acceleration

A mechanism with activation energy $E_a$ speeds up with temperature by
$$AF = \exp\left[\frac{E_a}{k}\left(\frac{1}{T_\text{use}} - \frac{1}{T_\text{stress}}\right)\right]$$
Voltage, current and humidity accelerate other mechanisms, each with its own model.

## Rates

A **FIT** is one failure per $10^9$ device-hours. With no failures in a test, the rate is bounded statistically: at 60% confidence, about 0.92 failures over the equivalent device-hours. MTTF in hours is $10^9$/FIT.

## Mechanisms

- **Electromigration:** the electron current pushes metal atoms along a wire, opening voids. Black: $\text{MTTF} = AJ^{-n}e^{E_a/kT}$, n ≈ 2, $E_a$ ≈ 0.9 eV for copper.
- **Time-dependent dielectric breakdown:** traps build up in a gate oxide under field until a conducting path forms. Lifetime falls steeply with field.
- **Bias-temperature instability and hot carriers:** interface traps form under gate bias and heat (BTI) or from energetic channel carriers (HCI), shifting the threshold roughly as $t^{0.2}$ to $t^{0.5}$.

## Statistics

Wear-out times follow a **Weibull** distribution, $F(t) = 1 - e^{-(t/\eta)^\beta}$: β > 1 means failures accelerate with age. Plotted against time, the failure rate traces the "bathtub": early defects, a long flat stretch, then wear-out.
:::

::: example
## 1000 parts run for 1000 hours at 125 °C with no failures. Using $E_a$ = 0.7 eV and use at 55 °C, what failure rate can be claimed at 60% confidence?

::: solution
1. **Acceleration factor.** With $k = 8.617 \times 10^{-5}$ eV/K,
   $$\begin{aligned} AF &= \exp\!\left[\frac{0.7}{k}\left(\frac{1}{328.15} - \frac{1}{398.15}\right)\right] \\ &= 78 \end{aligned}$$
2. **Equivalent device-hours.** The test equals
   $$10^6 \times 78 = 7.8 \times 10^7$$
   device-hours of use.
3. **Failure rate.** The 60% bound is
   $$\begin{aligned} \lambda &= \frac{0.92}{7.8 \times 10^7}\ \text{per hour} \\ &= 12\ \text{FIT} \end{aligned}$$
4. **What it means.** That's an MTTF of about $8 \times 10^7$ hours for one part, but a fleet of a million parts sees about 0.3 failures a day.

**Answer:** 12 FIT.
:::
:::

::: example
## A wire runs at 105 °C instead of 125 °C. How much longer does it last against electromigration ($E_a$ = 0.9 eV)?

::: solution
1. **Acceleration factor.** With $k = 8.617 \times 10^{-5}$ eV/K,
   $$\begin{aligned} &\exp\!\left[\frac{0.9}{k}\left(\frac{1}{378.15} - \frac{1}{398.15}\right)\right] \\ &= 4.0 \end{aligned}$$
   so the wire lasts four times longer.
2. **Why it matters.** A 20 °C cooler chip quadruples wire life, which is one reason thermal design matters as much to reliability as to performance.

**Answer:** four times longer.
:::
:::

::: example
## A transistor's threshold has shifted 5 mV after 1 year of bias-temperature stress, growing as $t^{0.2}$. What shift is expected at 10 years?

::: solution
1. **Shift at 10 years.**
   $$5 \times 10^{0.2} = 7.9\ \text{mV}$$
2. **Most of it comes early.** The slow power law means most of the shift comes early.
3. **Design margin.** Designs budget for the end-of-life value, often 20 to 50 mV, as extra timing margin.

**Answer:** about 7.9 mV.
:::
:::

::: check
kind: parts
given: E = 0.5 | 0.7 | 1; u = 40 | 55 | 85; s = 125 | 150

## A mechanism with $E_a$ = {E} eV is tested at {s} °C for use at {u} °C.

::: part
answer: exp(E/8.617e-5*(1/(u + 273.15) - 1/(s + 273.15)))
tolerance: 1%

### What is the acceleration factor?

::: misses
- [exp(E/8.617e-5*(1/u - 1/s))] Use kelvins.
- [any] $\exp[(E_a/k)(1/T_u - 1/T_s)]$.
:::
:::

::: part
answer: 1000*exp(E/8.617e-5*(1/(u + 273.15) - 1/(s + 273.15)))/8766
unit: years
tolerance: 1%

### How many years of use does a 1000-hour test represent?

::: misses
- [any] Hours × AF ÷ 8766.
:::
:::
:::

::: check
kind: parts
given: N = 100 | 1000 | 3000; h = 500 | 1000; A = 20 | 80 | 200

## {N} parts run {h} hours at an acceleration factor of {A} with no failures.

::: part
answer: 0.92/(N*h*A)*1e9
unit: FIT
tolerance: 0.5%

### What failure rate can be claimed at 60% confidence?

::: misses
- [any] 0.92 ÷ equivalent device-hours × $10^9$.
:::
:::

::: part
answer: N*h*A/0.92
unit: h
tolerance: 0.5%

### What MTTF does that imply?

::: misses
- [any] $10^9$/FIT.
:::
:::
:::

::: check
kind: parts
given: k = 1.5 | 2 | 3; n = 1.5 | 2; T1 = 105 | 85; T2 = 125 | 110; E = 0.7 | 0.9

## A wire's current density rises {k} times; separately, its temperature changes from {T2} °C to {T1} °C. Black's equation has n = {n} and $E_a$ = {E} eV.

::: part
answer: k^(-n)
tolerance: 0.5%

### What fraction of its life remains after the current increase alone?

::: misses
- [any] $k^{-n}$.
:::
:::

::: part
answer: exp(E/8.617e-5*(1/(T1 + 273.15) - 1/(T2 + 273.15)))
tolerance: 1%

### By what factor does the cooling extend its life?

::: misses
- [any] Arrhenius between the two temperatures.
:::
:::
:::

::: check
kind: parts
given: d = 2 | 5 | 10; p = 0.17 | 0.2 | 0.25; t = 10 | 15

## A threshold shift of {d} mV after one year grows as $t^{\given{p}}$.

::: part
answer: d*t^p
unit: mV
tolerance: 0.5%

### What will it be after {t} years?

::: misses
- [d*t] The growth is a weak power law, not linear.
- [any] $d\,t^p$.
:::
:::

::: part
answer: (50/d)^(1/p)
unit: years
tolerance: 1%

### When does it reach 50 mV?

::: misses
- [any] Solve $d\,t^p = 50$.
:::
:::
:::

::: check
kind: parts
given: e = 5 | 10 | 20; b = 1 | 2 | 4; t = 1 | 3

## Parts fail on a Weibull distribution with scale η = {e} years and shape β = {b}.

::: part
answer: (1 - exp(-(t/e)^b))*100
unit: %
tolerance: 0.5%

### What fraction has failed by {t} years?

::: misses
- [any] $1 - e^{-(t/\eta)^\beta}$.
:::
:::

::: part
answer: e*(-ln(0.99))^(1/b)
unit: years
tolerance: 0.5%

### When have 1% failed?

::: misses
- [any] Solve $F = 0.01$.
:::
:::
:::

::: check
kind: match

## Match each failure mechanism to what accelerates it in a test.

- Electromigration :: current density and temperature
- Time-dependent dielectric breakdown :: gate voltage (oxide field) and temperature
- Hot-carrier injection :: high drain voltage, often at low temperature
- Corrosion of unprotected bond pads :: humidity and temperature
- [extra] the clock frequency alone

::: misses
- [any] Each mechanism has its own driving stress.
:::
:::

::: check
kind: derivation
vars: E = 0.3..1.2, a = 280..360, b = 370..450, k = 1..4, n = 1..3

## A mechanism has activation energy E (eV); use is at a kelvins and the stress test at b kelvins. A wire's current density is multiplied by k under Black's law with exponent n.

::: step
answer: exp(E/8.617e-5*(1/a - 1/b))

### What is the acceleration factor?
:::

::: step
answer: k^(-n)

### What fraction of its life does the wire keep?
:::

::: step
answer: k^(-n)*exp(E/8.617e-5*(1/b - 1/a))

### What fraction if the wire also runs at the stress temperature?
:::

::: right
Right. Current and heat multiply: a hot wire carrying more current loses life on both counts.
:::
:::

::: check
kind: python

## Write `weibull_fit(times)`: given failure times (all units failed), estimate β and η by least-squares on the Weibull plot: sort the times, use median ranks $F_i = (i - 0.3)/(n + 0.4)$ for i = 1..n, and fit $\ln(-\ln(1 - F)) = \beta\ln t - \beta\ln\eta$. Return (β, η).

```python starter
import math

def weibull_fit(times):
    return (1.0, sum(times) / len(times))
```

```python solution
import math

def weibull_fit(times):
    t = sorted(times)
    n = len(t)
    xs = [math.log(v) for v in t]
    ys = [math.log(-math.log(1 - (i - 0.3) / (n + 0.4))) for i in range(1, n + 1)]
    mx, my = sum(xs) / n, sum(ys) / n
    b = sum((x - mx) * (y - my) for x, y in zip(xs, ys)) / sum((x - mx) ** 2 for x in xs)
    a = my - b * mx
    return (b, math.exp(-a / b))
```

```python tests
n = 20
eta, beta = 1000.0, 2.5
t = [eta * (-math.log(1 - (i - 0.3) / (n + 0.4))) ** (1 / beta) for i in range(1, n + 1)]
b, e = weibull_fit(t)
assert abs(b - 2.5) < 1e-9 and abs(e - 1000) < 1e-6, "Times placed exactly at the median ranks recover β and η."
b2, e2 = weibull_fit([120, 300, 420, 610, 800, 1100])
assert 1.2 < b2 < 2.0 and 500 < e2 < 900, "A small sample gives a plausible fit."
```

::: right
Right. Median-rank regression on the Weibull plot is the standard quick fit; maximum likelihood is better for small samples with censoring.
:::
:::

::: explain
## Why can a 1000-hour high-temperature test predict ten years of field life, and what assumption could make the prediction wrong?

::: model
Most wear-out mechanisms are thermally activated: their rate goes as $e^{-E_a/kT}$, so raising the temperature speeds them up by a factor that can be computed from the activation energy. Running at 125 °C instead of 55 °C may age a part eighty times faster, so a thousand hours of testing covers nearly nine years of use. The prediction rests on the assumption that the same mechanism, with the same activation energy, dominates in both conditions. If the stress triggers a mechanism that never occurs in use, the test is too pessimistic; if a mechanism with a lower activation energy dominates at use temperature, the test accelerates it less than assumed and the prediction is too optimistic.
:::
:::

::: practice
::: check
given: E = 0.6 | 0.9; s = 125 | 150
answer: exp(E/8.617e-5*(1/328.15 - 1/(s + 273.15)))
tolerance: 1%

## Acceleration from 55 °C to {s} °C at $E_a$ = {E} eV?

::: misses
- [any] Arrhenius.
:::
:::

::: check
given: F = 5 | 50 | 500
answer: 1e9/F
unit: h
tolerance: 0.5%

## MTTF at {F} FIT?

::: misses
- [any] $10^9$/FIT.
:::
:::

::: check
given: k = 1.2 | 1.5 | 2 | 2.5 | 3; n = 1 | 2
answer: k^(-n)
tolerance: 0.5%

## Life fraction after a {k}× current increase, n = {n}?

::: misses
- [any] $k^{-n}$.
:::
:::
:::