S1 · Midterm exam
Midterm exam: carriers, junctions and contacts
Twelve problems from lessons 1 to 24: carrier statistics, transport and recombination, the pn junction's electrostatics, capacitance, current, breakdown and tunneling, switching, heterojunctions, light detection and emission, Schottky barriers and contacts. Give yourself two hours and work without the lessons open. Silicon at 300 K: cm⁻³, kT/q = 0.02585 V, ε = 11.7ε₀ = 1.036 × 10⁻¹² F/cm, , cm⁻³, , cm²/(V·s). "Another set" deals a different exam.
Check
A silicon layer has = 4 × 10¹⁶ and = 1 × 10¹⁵ cm⁻³.
(a)
?
Write units the way you normally would: 1.5 eV, 1500 meV and 0.0015 keV are the same answer.
(b)
Resistivity (mobility from )?
Check
A p-type wafer ( = 5 × 10¹⁵ cm⁻³), 500 µm thick, has a bulk electron lifetime of 2 µs and surfaces with S = 1000 cm/s.
(a)
Electron diffusion length?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
(b)
Effective lifetime with both surfaces?
Check
n-type silicon ( = 1 × 10¹⁶ cm⁻³) has 1 × 10¹² cm⁻³ midgap traps with σ = 3 × 10⁻¹⁵ cm² ( = 10⁷ cm/s), under light generating 1 × 10²⁰ pairs per cm³ per second.
(a)
Excess hole density?
(b)
Quasi-Fermi level splitting?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An abrupt junction: = 1 × 10¹⁸, = 2 × 10¹⁵ cm⁻³, at 10 V reverse.
(a)
Depletion width?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
(b)
Capacitance per area?
Check
A one-sided diode 150 µm square has a slope of 0.25 pF⁻²/V.
(a)
Light-side doping?
(b)
Its breakdown voltage (Baliga's closed form)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A long diode of area 0.001 cm² has = 1 × 10¹⁶ cm⁻³ and = 0.3 µs on its n side.
(a)
, with from the mobility fit?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Voltage at 10 mA?
Check
A diode with a 0.5 µm depletion region ( = 0.1 µs) has an ideal of 3 × 10⁻¹¹ A/cm².
(a)
Ratio of reverse generation current to ?
(b)
Crossover voltage below which recombination dominates?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A one-sided junction has 4 × 10¹⁴ cm⁻³ on its light side.
(a)
Critical field?
Write units the way you normally would: 1.5 V/cm, 1500 mV/cm and 0.0015 kV/cm are the same answer.
(b)
Depletion width at breakdown?
(c)
Multiplication at 0.85 of breakdown (n = 4)?
Check
A rectifier with τ = 0.5 µs switches from 5 mA forward to 5 mA reverse.
(a)
Storage time by charge control?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
(b)
Charge stored at the moment of switching?
Check
A cell has = 35 mA/cm² and = 2 × 10⁻¹⁴ A/cm², with fill factor 0.84, under 100 mW/cm².
(a)
?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Efficiency?
Check
A photodiode with quantum efficiency 0.7 at 0.85 µm has 1 pF of capacitance and a 1000 Ω load.
(a)
Responsivity?
Write units the way you normally would: 1.5 A/W, 1500 mA/W and 0.0015 kA/W are the same answer.
(b)
RC bandwidth?
Check
A 0.55 eV Schottky barrier on n-type silicon ( = 1 × 10¹⁵ cm⁻³), 1 mm².
(a)
Built-in voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Forward voltage at 3 A?
Check
A contact 100 µm wide and 50 µm long sits on a 30 Ω-per-square layer, with = 1 × 10⁻⁷ Ω·cm².
(a)
Transfer length?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
(b)
Contact resistance?
Check
Built-in fields and band edges.
(a)
Field from doping that decays exponentially over 0.05 µm?
Write units the way you normally would: 1.5 kV/cm, 1500 V/cm and 0.0015 MV/cm are the same answer.
(b)
Effective density of states for a band with mass 0.55?
Check
A Haynes–Shockley measurement with a probe 0.5 cm downstream, a field of 30 V/cm and transit time 60 µs.
(a)
Mobility?
(b)
Spatial spread (standard deviation) on arrival, if D = 11 cm²/s?
Write units the way you normally would: 1.5 µm, 1500 nm and 0.0015 mm are the same answer.
Check
A diode has = 1 × 10¹⁶ cm⁻³ and its n region is 10 µm long, with = 40 µm and = 11 cm²/s, at 0.5 V forward.
(a)
Injected hole density at the depletion edge?
(b)
Hole current density?
Write units the way you normally would: 1.5 A/cm^2, 1500 mA/cm^2 and 0.0015 kA/cm^2 are the same answer.
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.