S11 · Lesson 14 · Battery charging and management
Constant-current, constant-voltage charging, cell balancing and keeping track of charge
Lesson 13's bidirectional converters move power into and out of batteries. A lithium-ion cell, though, is unforgiving: charge it above about 4.2 V and it degrades or catches fire, drain it too far and it's damaged, charge it too fast when cold and lithium plates onto the anode. A battery management system keeps every cell inside its limits. It charges with a constant current until the voltage reaches its limit, then holds the voltage while the current tapers; it balances cells in a series string so none overcharges; and it estimates the state of charge by counting coulombs, an integral whose errors only grow. Each of those is a power-electronics or measurement problem with numbers attached.
- A constant-current, constant-voltage (CC-CV) charge of a cell modeled as an open-circuit voltage rising from 3.0 to 4.2 V across its charge, with internal resistance . The current is held at the CC value until the terminal voltage reaches 4.2 V; then the voltage is held and the current falls as the cell's own voltage rises.
- More internal resistance means the cell hits 4.2 V earlier, so more of the charge goes in during the slow CV tail.
Predict
A 3000 mAh cell is charged at a constant 1500 mA (0.5C) until it reaches 4.2 V, then held at 4.2 V. Roughly how long does the whole charge take?
At 0.5C, 3000 mAh would take 2 hours at full current, but the cell reaches 4.2 V before it's full, so the last part goes in at a falling current during the CV phase. Typical totals are 2.5 to 3 hours at 0.5C. Charging faster shortens the CC phase but lengthens the share in CV, because the current's IR drop reaches the limit sooner.
Name it
CC-CV charging
- Constant current at a chosen C-rate (1C fills the cell's capacity in an hour) while the terminal voltage stays below the limit, typically 4.2 V per cell (4.1 to 4.4 V depending on chemistry).
- Constant voltage at the limit. The current falls as rises: .
- Termination when the current falls to a small fraction, often C/20.
Below about 0 °C, or above 45 °C, charging is reduced or stopped.
Packs and balancing
A pack of cells in series reaches V; cells in parallel add capacity. Cells differ slightly in capacity and self-discharge, so in a series string some fill before others. Passive balancing bleeds the fuller cells through resistors, ; active balancing moves charge between cells with small converters, wasting less but costing more.
State of charge
- Coulomb counting integrates the measured current: . A sensor offset accumulates an error without bound, so the estimate must be corrected.
- Voltage-based estimates use the open-circuit voltage curve, accurate only after the cell has rested and poor on flat parts of the curve.
- Real BMSs fuse both with a Kalman filter (as in S9), resetting the count when the cell is full or has rested.
Energy
A cell's energy is roughly its nominal voltage times its capacity: 3.7 V × 3 Ah = 11.1 Wh.
Worked example
A cell modeled as (with the fraction charged) and = 0.1 Ω is charged at 1 A to a 4.2 V limit. At what fraction does CV begin, and what current flows at 90% charge?
Show the solution
- Where CC ends. CC ends when the terminal voltage reaches 4.2 V:
- At 90%. The cell is still in CC, at 1 A.
- At 95%, in CV.
- The last stretch. The last 8% goes in at a falling current, which is why the last stretch of charging feels slow.
Answer CV begins at 91.7% charged, so at 90% the full 1 A still flows.
Worked example
A 4-cell pack's top cell is 100 mAh fuller than the others. A 47 Ω bleed resistor across it at 4.1 V: how fast does it bleed, and how long to balance?
Show the solution
- Bleed current.
- Time to balance.
- Resistor power.
- Why slow is fine. Passive balancing is slow by design; it runs at the end of every charge, keeping small mismatches from growing.
Answer it bleeds 87 mA and balances the cell in 1.15 hours, with the resistor dissipating 0.36 W.
Worked example
A BMS counts coulombs with a current sensor whose offset is 2 mA. If the count isn't corrected for 10 days, how much error does it accumulate, and what is that for a 3 Ah cell?
Show the solution
- Accumulated error. Ten days is 240 hours:
- Against the cell's capacity. so the gauge would read a sixth too high or too low.
- The remedy. That's why gauges recalibrate whenever the cell is fully charged or has rested long enough for its voltage to give the state of charge directly.
Answer the count drifts by 480 mAh, 16% of a 3 Ah cell.
Check
A 3000 mAh cell is charged at 0.5C. How long would the charge take if the full current flowed throughout (no CV tail)?
Check
A cell with and internal resistance 0.05 Ω is charged at 1 A to 4.2 V. At what percentage charge does the CV phase begin?
Check
During CV at 4.2 V, a cell with and 0.05 Ω internal resistance is at = 0.95. What current flows?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A bleed resistor of 33 Ω balances a cell at 4.1 V that is 200 mAh fuller than its neighbors.
(a)
What current does it bleed?
Write units the way you normally would: 1.5 mA, 1500 µA and 0.0015 A are the same answer.
(b)
How long does balancing take?
Check
A coulomb counter's current sensor has an offset of 2 mA. Uncorrected for 3 days, what error does it accumulate, as a percentage of a 5 Ah cell's capacity?
Check
A pack is built 7S2P from 5 Ah cells charged to 4.2 V each. What is its full-charge voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Why does a lithium-ion charger switch from constant current to constant voltage instead of charging at full current until the cell is full?
Check
Simulate a CC-CV charge. A cell of capacity 3 Ah has and internal resistance R = 0.05 Ω, starting empty. Charge at I = 1 A until reaches 4.2 V, then hold 4.2 V until the current falls below 0.15 A (C/20). Step 1 second at a time (update the charge after computing each step's current). Set t_total (hours), t_cc (hours in CC), and q_end, the final state of charge.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
An e-bike's 13-cell pack loses usable range over months, although each cell still has nearly its full capacity when tested alone. Explain how cell imbalance causes this, and what the BMS should do.
In a series string, the same current flows through every cell, but the cells differ slightly in capacity and self-discharge. Over many cycles their states of charge drift apart. Charging must stop when the fullest cell reaches 4.2 V, and discharging must stop when the emptiest cell reaches its minimum, so the pack's usable capacity is limited to the range in which every cell stays within its limits; with a growing spread, that range shrinks even though each cell alone is fine. The BMS should balance the cells, bleeding the fuller ones at the end of each charge (passive balancing) or moving charge between cells (active balancing), and should measure each cell's voltage individually so no cell is overcharged or overdischarged.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.