S11 · Lesson 13 · Bidirectional converters and the dual active bridge
Converters that move power both ways: synchronous buck–boost battery interfaces, constant-current and constant-voltage charging, and the dual active bridge's phase-shift power transfer
A battery is charged and discharged by the same converter. An electric car sends power from its battery to its motor and back during braking, and, with vehicle-to-grid, back to the house. Replace a converter's diodes with transistors and it can carry current either way; add a transformer with a full bridge on each side and the dual active bridge transfers kilowatts in either direction with a single control variable, the phase shift between its two bridges.
- The curve is a dual active bridge's power against the phase shift φ between its bridges, , for 400 V on both sides (referred), 100 kHz and the series inductance on the slider.
- Positive φ sends power from side 1 to side 2; negative φ reverses it. The maximum, at φ = 90°, is .
- Less inductance raises the maximum but makes the power more sensitive to small phase errors and raises the circulating current.
Predict
A dual active bridge with 400 V on both sides (referred to one side), 40 µH and 100 kHz must deliver 3 kW. Roughly what phase shift does it need?
The maximum is kW at 90°. For 3 kW, , so φ = 0.577 rad, 33°. Reversing the shift to −33° sends 3 kW back the other way.
Name it
Bidirectional DC–DC
Replacing a buck's diode with a second transistor gives a half-bridge leg with an inductor: run as a buck from the high side () or as a boost from the low side, the complementary transistor taking the switching role. The same hardware charges a battery from a bus or supports the bus from the battery.
Charging
Lithium-ion cells are usually charged at constant current until they reach their maximum voltage (about 4.2 V per cell), then at constant voltage while the current tapers. A rate of 1C is the current that would charge the capacity in an hour; the constant-current phase to about 80% at 0.5C takes about 1.6 h.
The dual active bridge
Two full bridges, each producing a square wave, drive the two sides of a transformer (ratio n:1) through a series inductance L (often its leakage). With side 2's voltage referred to side 1, , and side 2 lagging side 1 by φ,
Power flows from the leading bridge to the lagging one. When both bridges switch at zero voltage over a wide load range; when the voltages differ, light-load operation loses ZVS and carries large circulating current, which more elaborate modulation (adding phase shifts within each bridge) addresses.
Worked example
A DAB links a 400 V bus to a 48 V battery through an 8.33:1 transformer and 40 µH (referred to the 400 V side) at 100 kHz. What is its maximum power, and what phase shift gives 3 kW?
Show the solution
- Battery referred to the bus.
- Maximum power.
- Phase shift for 3 kW. The power is proportional to , so for 3 kW a quadratic whose smaller root is
- Reversing the flow. With the battery side leading instead, the same 3 kW would flow back to the bus.
Answer the maximum power is 5 kW, and 3 kW needs a phase shift of 0.577 rad (33.1°).
Worked example
A synchronous half-bridge leg links a 48 V battery to a 400 V bus. What duty cycle does its upper switch run at when charging the battery, and what does its lower switch run at when discharging?
Show the solution
- Charging. Charging is buck operation from 400 V, so the upper switch's duty is
- Discharging. Discharging is boost operation into 400 V, so the lower switch's duty is which leaves the upper switch on for the remaining 0.12.
- Which way power flows. It's the same switching pattern either way; the sign of the inductor current decides which way power flows.
Answer the upper switch runs at 0.12 when charging, and the lower switch at 0.88 when discharging.
Worked example
A 10 Ah battery is charged at 0.5C from empty. How long does the constant-current phase take to reach 80%, and what current is that?
Show the solution
- Charging current.
- Time to 80%. 80% of 10 Ah is 8 Ah:
- The rest of the charge. The constant-voltage phase then tops up the remaining 20% while the current tapers, typically over another hour or so, which is why fast charging stops at 80%.
Answer the constant-current phase takes 1.6 hours at 5 A.
Check
A DAB has 400 V on side 1 and 300 V (referred) on side 2, with 60 µH at 200 kHz.
(a)
What is its maximum power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What does it transfer at a 30° phase shift?
Check
A DAB with 400 V on each side (referred), 20 µH at 100 kHz, must deliver 3 kW.
(a)
What phase shift does it need?
Check
A synchronous leg links a 48 V battery to a 380 V bus.
(a)
What duty does the upper switch run at while charging the battery?
(b)
What duty does the lower switch run at while discharging?
Check
A 50 Ah battery is charged from empty at 0.3C until it reaches 80%.
(a)
What is the charging current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
How long does that phase take?
Check
A DAB with 400 V and 400 V (referred) at 100 kHz must be able to deliver 20 kW at a phase shift of 90°.
(a)
What series inductance does that allow at most?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A DAB's transformer has ratio 8.33:1 and its low side sits at 24 V.
(a)
What does the low side look like referred to the high side?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
What decides which way power flows in a dual active bridge?
Check
A DAB has V and W (referred) on its two sides, phase shift p (radians), frequency f and series inductance L.
Step 1
What power does it transfer?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What is its maximum?
Check
Write dab_power(V1, V2, phi, f, L): integrate the inductor current of a DAB driven by a ±V1 square wave and a ±V2 square wave lagging by phi (radians) over one period (100 000 steps), remove its average to get the steady state, and return the average of V1's square wave times the current.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why is the dual active bridge attractive for vehicle chargers and solid-state transformers?
These applications need isolation, power flow in both directions and high efficiency at high power. The dual active bridge provides all three with a symmetric structure: a full bridge on each side of a high-frequency transformer, with the transformer's leakage inductance doing the job of the energy-transfer element. Power is set by a single phase shift between the bridges, whose sign sets the direction, so the same hardware charges and discharges. When the two voltages are matched through the turns ratio, the switches turn on at zero voltage across a wide load range, which allows high switching frequencies and a small transformer.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.