title: Capacitors and reliability
heading: Choosing electrolytic, film and ceramic capacitors, ripple-current heating, the ten-degree rule for electrolytic life, ceramic capacitance loss under DC bias, failure rates in FIT, MTBF and Arrhenius acceleration
eyebrow: S11 · Lesson 44 · Capacitors and reliability
xp: 50
---

::: hook
When a power supply fails in the field, the culprit is very often a capacitor. Electrolytic capacitors dry out, faster the hotter they run; ceramic capacitors lose most of their capacitance at their working voltage and crack under board flexing; film capacitors are robust but bulky. A converter's lifetime is designed, not hoped for: by estimating each part's temperature, its ripple heating and its failure rate, and adding them up into a number that a customer can rely on.
:::

::: play
- The curve is an aluminum electrolytic capacitor's expected life against its core temperature, for a part rated 5000 hours at 105 °C, by the ten-degree rule: $L = L_0 \cdot 2^{(T_0 - T)/10}$.
- At 65 °C it lasts 80 000 hours, about nine years of continuous running; at 95 °C only 10 000 hours.
- Every ten degrees of cooling doubles the life, which is why capacitor placement and airflow are reliability decisions.
:::

```sim plot
view: graph
x: T = 40..105
y: L = 1000..1000000 log
plot: 5000*2^((105 - T)/10) | label: expected life, hours
plot: 87660 + 0*T | dashed | label: ten years
```

::: predict
## An electrolytic rated 5000 h at 105 °C runs at 65 °C, but its ripple current adds another 4 °C of internal heating. What does that do to its life?

- [ ] Nothing: 4 °C is small
- [x] It cuts the life by about a quarter
- [ ] It halves the life
- [ ] It doubles the life

::: reveal
The life scales as $2^{-\Delta T/10}$, so 4 °C costs a factor of $2^{-0.4} = 0.76$: from 80 000 to about 61 000 hours. Ripple heating, $I_\text{rms}^2\,\text{ESR}$ through the capacitor's thermal resistance, is as important as ambient temperature.
:::
:::

::: nameit
## Capacitor types

- **Aluminum electrolytic**: the most capacitance per volume and per dollar at tens to hundreds of volts, but with significant ESR, a ripple-current rating, and a life limited by electrolyte loss. Life roughly doubles for each 10 °C below the rated temperature: $L = L_0 \cdot 2^{(T_0 - T)/10}$.
- **Film** (polypropylene): low loss, high ripple capability and self-healing, long life, but bulky; preferred for DC links in inverters.
- **Ceramic (MLCC)**: tiny ESR and ESL, excellent at high frequency, but class 2 dielectrics (X5R, X7R) lose much of their capacitance under DC bias, often half or more at rated voltage, and with temperature. The capacitance that matters is the derated value.

## Ripple heating

A capacitor carrying ripple current $I_\text{rms}$ dissipates $I_\text{rms}^2\,\text{ESR}$, raising its core by that power times its thermal resistance. Datasheets give a ripple-current rating at a frequency and temperature; exceeding it shortens life rapidly.

## Failure rates

Random failure rates are quoted in **FIT**, failures per $10^9$ device-hours. For a system of parts in series (any failure is a system failure), rates add, and with a constant total rate λ:
$$\text{MTBF} = \frac{1}{\lambda}, \qquad P(\text{failure by } t) = 1 - e^{-\lambda t}$$
Temperature accelerates most failure mechanisms by the **Arrhenius factor**
$$AF = \exp\left[\frac{E_a}{k}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)\right]$$
with activation energy $E_a$ (often 0.5 to 1 eV), Boltzmann's constant $k = 8.617 \times 10^{-5}$ eV/K and temperatures in kelvin.

## Mission profiles

A part that spends fractions $f_i$ of its life at temperatures with lives $L_i$ wears out at the combined rate $\sum f_i/L_i$ (Miner's rule), so its life is $1/\sum(f_i/L_i)$. Short hot periods often dominate.
:::

::: example
## An electrolytic rated 5000 h at 105 °C carries 2 A RMS through 50 mΩ of ESR, with 20 K/W from its core to 65 °C surroundings. What life should it have?

::: solution
1. **Ripple heating.**
   $$\begin{aligned} P &= 2^2 \times 0.05 \\ &= 0.2\ \text{W} \end{aligned}$$
   raising the core 4 K, to 69 °C.
2. **Life.**
   $$\begin{aligned} L &= 5000 \times 2^{(105 - 69)/10} \\ &= 5000 \times 2^{3.6} \\ &= 60\,600\ \text{h} \end{aligned}$$
   about 6.9 years of continuous operation.
3. **Compare with the ambient alone.** That's 24% less than the 80 000 hours the ambient alone suggests.

**Answer:** about 60,600 hours, 6.9 years of continuous operation.
:::
:::

::: example
## A converter has 50 small parts at 10 FIT, four MOSFETs at 50 FIT and two electrolytics at 200 FIT. What is its MTBF, and how likely is it to fail within ten years of continuous use?

::: solution
1. **Total failure rate.**
   $$\begin{aligned} \lambda &= (500 + 200 + 400)\ \text{FIT} \\ &= 1100\ \text{FIT} \end{aligned}$$
   which is $1.1 \times 10^{-6}$ per hour.
2. **MTBF.**
   $$\begin{aligned} \text{MTBF} &= \frac{1}{1.1 \times 10^{-6}}\ \text{h} \\ &= 909\,000\ \text{h} \end{aligned}$$
   about 104 years.
3. **Chance of failing in ten years.** Ten years is 87 660 hours:
   $$\begin{aligned} p &= 1 - e^{-87\,660/909\,000} \\ &= 9.2\% \end{aligned}$$
4. **What it means.** An MTBF far longer than the product's life still means many field failures across a large fleet.

**Answer:** the MTBF is 909,000 hours (about 104 years), and the chance of failing within ten years is 9.2%.
:::
:::

::: example
## A failure mechanism has an activation energy of 0.7 eV. How much faster does it act at 85 °C than at 55 °C?

::: solution
1. **The exponent.** With the temperatures in kelvin:
   $$\begin{aligned} x &= \frac{0.7}{8.617 \times 10^{-5}} \\ &\quad \times \left(\frac{1}{328.15} - \frac{1}{358.15}\right) \\ &= 2.07 \end{aligned}$$
2. **Acceleration factor.**
   $$\begin{aligned} AF &= e^{x} \\ &= 7.95 \end{aligned}$$
3. **What it means.** A 30 °C rise makes failures eight times as frequent, which is why accelerated life tests run hot, and why a converter's reliability depends so much on its thermal design (lesson 43).

**Answer:** it acts 7.95 times faster at 85 °C.
:::
:::

::: check
kind: parts
given: L = 2000 | 5000 | 10000; R = 85 | 105; T = 45 | 65 | 80

## An electrolytic rated {L} h at {R} °C runs with its core at {T} °C.

::: part
answer: L*2^((R - T)/10)
unit: h
tolerance: 0.5%

### What life should it have?

::: misses
- [L*(R - T)/10] Life doubles per 10 °C: an exponent, not a multiple.
- [any] $L_0 \cdot 2^{(T_0 - T)/10}$.
:::
:::

::: part
answer: L*2^((R - T)/10)/8766
unit: years
tolerance: 0.5%

### How many years of continuous operation is that?

::: misses
- [any] A year is 8766 hours.
:::
:::
:::

::: check
kind: parts
given: I = 0.5 | 1.5 | 3; E = 20 | 60 | 150; R = 10 | 30

## A capacitor carries {I} A RMS of ripple through {E} mΩ of ESR, with {R} K/W from core to surroundings.

::: part
answer: I^2*E*1e-3
unit: W
tolerance: 0.5%

### How much does it dissipate?

::: misses
- [any] $I_\text{rms}^2\,\text{ESR}$.
:::
:::

::: part
answer: 2^(-I^2*E*1e-3*R/10)
tolerance: 0.5%

### By what factor does the self-heating multiply its life?

::: misses
- [any] $2^{-\Delta T/10}$ with $\Delta T = PR_\theta$.
:::
:::
:::

::: check
kind: parts
given: C = 10 | 22 | 47; k = 0.3 | 0.5 | 0.7

## An X5R ceramic rated {C} µF keeps {k} of its capacitance at the working DC bias, and loses another 15% at its operating temperature.

::: part
answer: C*k*0.85
unit: µF
tolerance: 0.5%

### What capacitance does the circuit actually get?

::: misses
- [C] Use the derated value.
- [any] Nominal × bias factor × temperature factor.
:::
:::
:::

::: check
kind: parts
given: a = 20 | 100; f = 5 | 20; b = 2 | 6; g = 50 | 150; c = 1 | 3; h = 100 | 500

## A board has {a} parts at {f} FIT, {b} parts at {g} FIT and {c} parts at {h} FIT.

::: part
answer: a*f + b*g + c*h
unit: FIT
tolerance: 0.5%

### What is its total failure rate?

::: misses
- [any] Rates add.
:::
:::

::: part
answer: 1e9/(a*f + b*g + c*h)/8766
unit: years
tolerance: 0.5%

### What is its MTBF?

::: misses
- [any] $10^9/\text{FIT}$ hours.
:::
:::

::: part
answer: (1 - exp(-5*8766*(a*f + b*g + c*h)*1e-9))*100
unit: %
tolerance: 0.5%

### What fraction fail within five years of continuous use?

::: misses
- [any] $1 - e^{-\lambda t}$.
:::
:::
:::

::: check
kind: parts
given: E = 0.5 | 0.7 | 1; a = 25 | 55; b = 85 | 125

## A failure mechanism has activation energy {E} eV.

::: part
answer: exp(E/8.617e-5*(1/(a + 273.15) - 1/(b + 273.15)))
tolerance: 0.5%

### By what factor does it speed up from {a} °C to {b} °C?

::: misses
- [any] $\exp[(E_a/k)(1/T_1 - 1/T_2)]$ in kelvin.
:::
:::
:::

::: check
kind: parts
given: p = 0.5 | 0.7 | 0.9; T = 45 | 55; U = 85 | 95

## An electrolytic rated 5000 h at 105 °C spends {p} of its time at {T} °C and the rest at {U} °C.

::: part
answer: 1/(p/(5000*2^((105 - T)/10)) + (1 - p)/(5000*2^((105 - U)/10)))
unit: h
tolerance: 0.5%

### What life does Miner's rule give?

::: misses
- [p*5000*2^((105 - T)/10) + (1 - p)*5000*2^((105 - U)/10)] Wear rates add, not lives: $1/\sum(f_i/L_i)$.
- [any] $1/\sum(f_i/L_i)$.
:::
:::
:::

::: check
kind: choice

## A designer replaces a 470 µF electrolytic output capacitor with 470 µF of X5R ceramics rated 6.3 V on a 5 V rail. What goes wrong?

- [ ] Nothing: same capacitance, lower ESR
- [x] At 5 V of DC bias the ceramics keep only a fraction of their rated capacitance, and their much lower ESR removes the zero that the loop compensation relied on, so both the ripple and the loop's phase margin can be far worse than expected
- [ ] Ceramics can't carry ripple current
- [ ] The ESR rises

::: misses
- [1] DC bias and the missing ESR zero both bite.
- [3] They carry ripple well.
- [4] ESR falls, which is part of the problem.
:::
:::

::: check
kind: derivation
vars: L = 1000..20000, R = 85..125, T = 20..100, l = 0.0000001..0.00001, t = 1000..200000

## A capacitor rated L hours at R °C runs at T; separately, a system has a constant failure rate l per hour.

::: step
answer: L*2^((R - T)/10)

### What is the capacitor's life?
:::

::: step
answer: 1/l

### What is the system's MTBF?
:::

::: step
answer: 1 - exp(-l*t)

### What fraction fail by time t?
:::

::: right
Right. Wear-out (the capacitor) and random failures (the FIT rate) are different models, and a design must budget for both.
:::
:::

::: check
kind: python

## Write `miner_life(profile, L0, T0)`: for a list of (fraction of time, temperature) pairs and an electrolytic rated L0 hours at T0, return the expected life by the ten-degree rule and Miner's rule, and `mtbf_hours(parts)`: the MTBF from a list of (count, FIT) pairs.

```python starter
def miner_life(profile, L0, T0):
    return L0

def mtbf_hours(parts):
    return 1e9
```

```python solution
def miner_life(profile, L0, T0):
    rate = sum(f / (L0 * 2 ** ((T0 - T) / 10)) for f, T in profile)
    return 1 / rate

def mtbf_hours(parts):
    return 1e9 / sum(n * fit for n, fit in parts)
```

```python tests
assert abs(miner_life([(1.0, 65)], 5000, 105) - 80000) < 1e-6, "Constant 65 °C: 80 000 h."
assert abs(miner_life([(0.7, 55), (0.3, 85)], 5000, 105) - 51612.9) < 0.1, "Mostly cool, sometimes hot: 51 600 h."
assert abs(mtbf_hours([(50, 10), (4, 50), (2, 200)]) - 909090.9) < 0.1, "The example's 909 000 h."
```

::: right
Right. The hot 30% of the time consumes more than three quarters of the life, so mission profiles matter more than averages.
:::
:::

::: explain
## Why does an MTBF of a hundred years not mean a product will last a hundred years?

::: model
MTBF describes the constant rate of random failures during a product's useful life, so it says what fraction of a large population fails per year, not how long any one unit lasts. A hundred-year MTBF means roughly one percent of units fail per year from random causes, so a few percent fail over a typical service life. It also ignores wear-out: components like electrolytic capacitors and fans have finite lives set by temperature and use, and once they approach that life, failures rise sharply regardless of the MTBF. A product's real lifetime is set by its weakest wear-out component, while its MTBF sets how many units fail randomly along the way.
:::
:::

::: practice
::: check
given: L = 3000 | 8000; T = 55 | 75
answer: L*2^((105 - T)/10)
unit: h
tolerance: 0.5%

## Life of a {L} h, 105 °C part at {T} °C?

::: misses
- [any] $L_0 \cdot 2^{(105 - T)/10}$.
:::
:::

::: check
given: F = 50 | 100 | 300 | 1000 | 2500 | 5000
answer: 1e9/F/8766
unit: years
tolerance: 0.5%

## MTBF at {F} FIT?

::: misses
- [any] $10^9/\text{FIT}$ hours.
:::
:::

::: check
given: I = 1 | 2.5; E = 40 | 100
answer: I^2*E*1e-3
unit: W
tolerance: 0.5%

## Ripple loss: {I} A RMS, {E} mΩ ESR?

::: misses
- [any] $I^2\,\text{ESR}$.
:::
:::
:::