S11 · Lesson 23 · Current-programmed control
Peak current-mode control, the inductor-current perturbation that grows from cycle to cycle above 50% duty, slope compensation and its minimum, and the simpler single-pole plant that current control leaves for the voltage loop
Most modern DC-DC controllers don't set the duty cycle directly. Instead each cycle the switch turns on with the clock and turns off when the inductor current reaches a level set by the voltage loop. Controlling the peak current gives free cycle-by-cycle current limiting and turns the inductor into something like a current source, which removes the LC resonance from the voltage loop. But above 50% duty a strange instability appears: a small disturbance in the inductor current grows from one cycle to the next. A small artificial ramp added to the current fixes it.
- How a small perturbation in the inductor current evolves from cycle to cycle in a peak current-mode converter: multiplied by each period.
- Here the rising slope is normalized to 1, the falling slope is for a buck, and the compensation ramp is a fraction k of .
- With k = 0 and D above 0.5, |α| > 1 and the perturbation grows, alternating in sign: subharmonic oscillation. Raising k makes it die out.
Predict
A boost runs at D = 0.75 from 12 V to 48 V with L = 47 µH under peak current-mode control and no slope compensation. What happens to a small current disturbance?
The rising slope is = 0.255 A/µs and the falling slope = 0.766 A/µs. A disturbance changes by = −3 each cycle: the inductor current alternates between long and short pulses, at half the switching frequency. Adding a ramp of slope makes α = −0.6.
Name it
Peak current-mode control
The clock turns the switch on; a comparator turns it off when the sensed inductor current (plus a compensating ramp of slope ) reaches a control current from the voltage loop.
The perturbation
If the inductor current starts a cycle off by , the turn-off moves and it ends the cycle off by
where and are the magnitudes of the inductor current's rising and falling slopes. Without compensation α = in CCM (by volt-second balance), so the loop is unstable for D > 0.5.
Slope compensation
Stability needs |α| < 1, that is . A common choice is , which makes the current loop stable at every duty cycle (α = 0 at , the deadbeat value). Too much compensation turns the controller back toward voltage mode.
The voltage loop's plant
With the current loop controlling the inductor current, the inductor no longer acts as an independent state at low frequency: a current-mode buck's control-to-output response is roughly a single pole at (plus the ESR zero and a double pole near ). A type II compensator suffices. The boost's RHP zero remains.
Worked example
Is current-mode control stable without compensation for the 12 V to 3.3 V buck (L = 10 µH)?
Show the solution
- Current slopes.
- Stability. Stable, since D = 0.275 < 0.5: a perturbation shrinks by more than half each cycle.
- Voltage-loop plant. It has a pole at
Answer yes: α = −0.38, so it's stable without compensation, and its voltage-loop plant has a pole at 4.4 kHz.
Worked example
What compensation does the boost need?
Show the solution
- Minimum compensation. which just reaches |α| = 1.
- With . That's 0.383 A/µs, so
- How fast a disturbance dies. In ten cycles it falls to of itself.
Answer it needs at least 0.255 A/µs of compensating ramp; using = 0.383 A/µs gives α = −0.6.
Worked example
A current-mode buck converts 12 V to 7.2 V with L = 6.8 µH. Is it stable without slope compensation, and what does give?
Show the solution
- Duty cycle.
- Current slopes.
- Without compensation. Each cycle's error grows by half, and the loop oscillates at half the switching frequency.
- With . decaying quickly.
Answer without compensation α = −1.5 and the loop oscillates at half the switching frequency; brings α to −0.43.
Check
A buck from 12 V to 1.2 V has L = 47 µH. What's its inductor current's rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
Check
A converter under peak current-mode control without slope compensation runs at D = 0.6. What's α?
Check
A current-mode converter's inductor current rises at 0.2 A/µs and falls at 0.6 A/µs. What's the least compensating slope that keeps it stable?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
Check
With , what's α for slopes = 0.2 and = 0.6 A/µs?
Check
A current loop has α = −0.6. By what factor has a perturbation's magnitude shrunk after 5 cycles?
Check
A current-mode buck feeds 2 Ω with 22 µF of output capacitance. Where's its dominant control-to-output pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A current-mode buck converts 12 V to 0.3 of that with L = 15 µH.
(a)
What is the current's rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
What is α with ?
Check
A current loop has rising slope a, falling slope b and compensating slope c.
Step 1
What is α?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
By what factor does a perturbation's magnitude change after n cycles?
Explain why
Why does peak current-mode control become unstable above 50% duty without slope compensation?
The switch turns off when the inductor current reaches the control level, so if the current starts a cycle a little high, it reaches the level a little early and the switch turns off sooner. The current then falls at the off-time slope for longer than normal. Whether the error at the end of the cycle is smaller or larger than at the start depends on the ratio of the slopes: the early turn-off shortens the rise by the error divided by the rising slope, and that extra falling time removes the error times the ratio of falling to rising slope. When the falling slope is steeper than the rising one, which volt-second balance says happens for D above 0.5, the correction overshoots and the error grows, flipping sign each cycle. An added ramp makes the turn-off less sensitive to the starting error and restores stability.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.