S11 · Lesson 9 · The discontinuous conduction mode
Why the inductor current falls to zero at light load when the rectifier is a diode, the dimensionless parameter K and the mode boundary, conversion ratios in DCM for the buck, boost and buck-boost, and the load dependence that results
Lighten the load on a buck converter with a diode rectifier and something odd happens: below a certain current its output voltage starts to rise, even though the duty cycle hasn't changed. The inductor current's ripple is fixed by the voltages and inductance, so when the average falls below half the ripple, the current would have to go negative to keep its triangle shape, and the diode won't allow that. The current stops at zero for part of each period, and every result derived for continuous conduction changes.
- A buck converter's conversion ratio against the dimensionless load parameter for a fixed duty cycle (log axis).
- At heavy load (large K) it's the familiar M = D. Below the boundary the converter enters DCM and M rises toward 1 as the load lightens.
- A controller has to cope with both modes, and the plant's dynamics differ between them: the averaged models of lesson 16 assume continuous conduction.
Predict
A 12 V to 3.3 V buck (D = 0.275, L = 10 µH, 500 kHz, diode rectifier) has its load lightened to 50 Ω. Holding D fixed, what does its output become?
K = 2L/(RT_s) = 2 × 10 µH × 500 kHz/50 Ω = 0.2, below = 1 − 0.275 = 0.725, so it's in DCM, where = 0.454: 5.45 V. The feedback loop would cut D to restore 3.3 V. The mode boundary is at = 13.8 Ω, or 0.24 A.
Name it
Where DCM comes from
With a diode as the rectifier, the inductor current can't reverse. If its average falls below half its peak-to-peak ripple, it reaches zero before the period ends and stays there: a third subinterval with both switches off.
The boundary
Define . The converter is in DCM when :
| Converter | M in DCM | |
|---|---|---|
| Buck | ||
| Boost | ||
| Buck-boost |
The critical load resistance follows from : .
Consequences
In DCM the output depends on the load as well as the duty cycle; the converter behaves at low frequency like a power source rather than a voltage source, and its small-signal transfer function loses a pole. Synchronous rectifiers let the current reverse, keeping a buck in CCM at all loads at the cost of circulating current; many controllers deliberately allow DCM at light load for efficiency.
Worked example
Find the boundary load for the buck above and its output at 50 Ω.
Show the solution
- Critical load.
- Boundary current. CCM holds down to which is half the 0.48 A ripple of lesson 3.
- Output at 50 Ω. At 50 Ω, K = 0.2 and M = 0.454, so
Answer the boundary load is 13.8 Ω (0.24 A), and at 50 Ω the output rises to 5.45 V.
Worked example
A boost at D = 0.5 runs with K = 0.05. Is it in DCM, and what's its conversion ratio?
Show the solution
- Check the mode. which is more than 0.05: DCM.
- Conversion ratio. against 2 in CCM.
- At light load. A lightly loaded boost's output climbs, and with no load at all it would rise without limit, which is why boosts need a minimum load or a controller that skips pulses.
Answer it's in DCM, with M = 2.79 against 2 in CCM.
Worked example
A buck-boost runs at D = 0.3 with K = 0.01. Is it in DCM, and what's its conversion ratio?
Show the solution
- Check the mode. and 0.01 is far below it: DCM.
- Conversion ratio. against 0.43 in CCM.
- At light load. A DCM converter's output climbs far above its CCM value for the same duty cycle, so its controller must cut D sharply as the load falls, and an open-loop design would overvoltage.
Answer it's in DCM, with |M| = 3.0 against 0.43 in CCM.
Check
A converter has L = 22 µH, = 100 kHz and a 50 Ω load. What's K?
Check
A buck with a diode rectifier has L = 10 µH and runs at 200 kHz with D = 0.7. Above what load resistance does it enter DCM?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A buck runs in DCM at D = 0.4 with K = 0.05. What's its conversion ratio?
Check
A boost runs in DCM at D = 0.5 with K = 0.01. What's its conversion ratio?
Check
A buck-boost runs in DCM at D = 0.35 with K = 0.04. What's the magnitude of its conversion ratio?
Check
A boost has L = 10 µH at 100 kHz and D = 0.7. Above what load resistance does it enter DCM?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A buck-boost with L = 10 µH switches at 100 kHz into 500 Ω at D = 0.4.
(a)
What is K?
(b)
What is the magnitude of its conversion ratio?
Check
A buck runs in DCM at duty cycle D with parameter K.
Step 1
What is its conversion ratio?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What K marks the CCM boundary?
Explain why
Why does a buck converter's output rise at light load in DCM when the duty cycle is held fixed?
In continuous conduction the inductor is connected either to the input or to ground for the whole period, and volt-second balance forces the output to . In DCM there's a third interval in which the inductor current is zero, so the inductor has no voltage across it and the switch node floats up to the output voltage. That interval removes some of the time during which the output was being pulled down toward ground, so the average voltage at the switch node, and hence the output, rises above . The lighter the load, the longer the idle interval and the higher the output, approaching at no load.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.