title: The discontinuous conduction mode
heading: Why the inductor current falls to zero at light load when the rectifier is a diode, the dimensionless parameter K and the mode boundary, conversion ratios in DCM for the buck, boost and buck-boost, and the load dependence that results
eyebrow: S11 · Lesson 9 · The discontinuous conduction mode
xp: 50
---

::: hook
Lighten the load on a buck converter with a diode rectifier and something odd happens: below a certain current its output voltage starts to rise, even though the duty cycle hasn't changed. The inductor current's ripple is fixed by the voltages and inductance, so when the average falls below half the ripple, the current would have to go negative to keep its triangle shape, and the diode won't allow that. The current stops at zero for part of each period, and every result derived for continuous conduction changes.
:::

::: play
- A buck converter's conversion ratio against the dimensionless load parameter $K = 2L/(RT_s)$ for a fixed duty cycle (log axis).
- At heavy load (large K) it's the familiar M = D. Below the boundary $K_\text{crit} = 1 - D$ the converter enters DCM and M rises toward 1 as the load lightens.
- A controller has to cope with both modes, and the plant's dynamics differ between them: the averaged models of lesson 16 assume continuous conduction.
:::

```sim plot
view: graph
x: K = 0.01..3 log
y: M = 0..1
slider: D = 0.1..0.9 = 0.275
plot: step(K - (1 - D))*D + (1 - step(K - (1 - D)))*2/(1 + sqrt(1 + 4*K/D^2)) | samples: 600 | label: buck conversion ratio
plot: D + 0*K | dashed | color: ch3 | label: CCM value
marker: x = 1 - D | label: boundary
```

::: predict
## A 12 V to 3.3 V buck (D = 0.275, L = 10 µH, 500 kHz, diode rectifier) has its load lightened to 50 Ω. Holding D fixed, what does its output become?

- [ ] 3.3 V still
- [ ] Lower, about 2.5 V
- [x] Higher, about 5.5 V
- [ ] 12 V

::: reveal
K = 2L/(RT_s) = 2 × 10 µH × 500 kHz/50 Ω = 0.2, below $K_\text{crit}$ = 1 − 0.275 = 0.725, so it's in DCM, where $M = 2/(1 + \sqrt{1 + 4K/D^2})$ = 0.454: 5.45 V. The feedback loop would cut D to restore 3.3 V. The mode boundary is at $R_\text{crit}$ = 13.8 Ω, or 0.24 A.
:::
:::

::: nameit
## Where DCM comes from

With a diode as the rectifier, the inductor current can't reverse. If its average falls below half its peak-to-peak ripple, it reaches zero before the period ends and stays there: a third subinterval with both switches off.

## The boundary

Define $K = \dfrac{2L}{RT_s}$. The converter is in DCM when $K < K_\text{crit}(D)$:

| Converter | $K_\text{crit}$ | M in DCM |
|---|---|---|
| Buck | $1 - D$ | $\dfrac{2}{1 + \sqrt{1 + 4K/D^2}}$ |
| Boost | $D(1 - D)^2$ | $\dfrac{1 + \sqrt{1 + 4D^2/K}}{2}$ |
| Buck-boost | $(1 - D)^2$ | $-D/\sqrt{K}$ |

The critical load resistance follows from $K = K_\text{crit}$: $R_\text{crit} = 2Lf_s/K_\text{crit}$.

## Consequences

In DCM the output depends on the load as well as the duty cycle; the converter behaves at low frequency like a power source rather than a voltage source, and its small-signal transfer function loses a pole. Synchronous rectifiers let the current reverse, keeping a buck in CCM at all loads at the cost of circulating current; many controllers deliberately allow DCM at light load for efficiency.
:::

::: example
## Find the boundary load for the buck above and its output at 50 Ω.

::: solution
1. **Critical load.**
   $$\begin{aligned} R_\text{crit} &= \frac{2Lf_s}{1 - D} \\ &= \frac{2 \times 10\ \mu\text{H} \times 500\text{ kHz}}{0.725} \\ &= 13.8\ \Omega \end{aligned}$$
2. **Boundary current.** CCM holds down to
   $$\begin{aligned} I_\text{crit} &= \frac{3.3\ \text{V}}{13.8\ \Omega} \\ &= 0.24\ \text{A} \end{aligned}$$
   which is half the 0.48 A ripple of lesson 3.
3. **Output at 50 Ω.** At 50 Ω, K = 0.2 and M = 0.454, so
   $$\begin{aligned} V &= 0.454 \times 12\ \text{V} \\ &= 5.45\ \text{V} \end{aligned}$$

**Answer:** the boundary load is 13.8 Ω (0.24 A), and at 50 Ω the output rises to 5.45 V.
:::
:::

::: example
## A boost at D = 0.5 runs with K = 0.05. Is it in DCM, and what's its conversion ratio?

::: solution
1. **Check the mode.**
   $$\begin{aligned} K_\text{crit} &= 0.5 \times 0.5^2 \\ &= 0.125 \end{aligned}$$
   which is more than 0.05: DCM.
2. **Conversion ratio.**
   $$\begin{aligned} M &= \frac{1 + \sqrt{1 + 4 \times 0.25/0.05}}{2} \\ &= \frac{1 + \sqrt{21}}{2} \\ &= 2.79 \end{aligned}$$
   against 2 in CCM.
3. **At light load.** A lightly loaded boost's output climbs, and with no load at all it would rise without limit, which is why boosts need a minimum load or a controller that skips pulses.

**Answer:** it's in DCM, with M = 2.79 against 2 in CCM.
:::
:::

::: example
## A buck-boost runs at D = 0.3 with K = 0.01. Is it in DCM, and what's its conversion ratio?

::: solution
1. **Check the mode.**
   $$\begin{aligned} K_\text{crit} &= (1 - D)^2 \\ &= 0.49 \end{aligned}$$
   and 0.01 is far below it: DCM.
2. **Conversion ratio.**
   $$\begin{aligned} |M| &= \frac{D}{\sqrt K} \\ &= \frac{0.3}{0.1} \\ &= 3.0 \end{aligned}$$
   against 0.43 in CCM.
3. **At light load.** A DCM converter's output climbs far above its CCM value for the same duty cycle, so its controller must cut D sharply as the load falls, and an open-loop design would overvoltage.

**Answer:** it's in DCM, with |M| = 3.0 against 0.43 in CCM.
:::
:::

::: check
given: L = 4.7 | 22 | 100; f = 100 | 500; R = 5 | 50
answer: 2*L*1e-6*f*1e3/R
tolerance: 0.5%

## A converter has L = {L} µH, $f_s$ = {f} kHz and a {R} Ω load. What's K?

::: right
Right. $2L/(RT_s) = 2Lf_s/R$ = {answer}.
:::

::: misses
- [L*1e-6*f*1e3/R] Include the 2.
- [any] Not yet. $K = 2L/(RT_s)$.
:::
:::

::: check
given: L = 4.7 | 10 | 47; f = 200 | 400; D = 0.2 | 0.4 | 0.7
answer: 2*L*1e-6*f*1e3/(1 - D)
unit: Ω
tolerance: 0.5%

## A buck with a diode rectifier has L = {L} µH and runs at {f} kHz with D = {D}. Above what load resistance does it enter DCM?

::: right
Right. $R_\text{crit} = 2Lf_s/(1 - D)$ = {answer} Ω.
:::

::: misses
- [2*L*1e-6*f*1e3/D] For the buck $K_\text{crit} = 1 - D$.
- [any] Not yet. Set K equal to $K_\text{crit}$.
:::
:::

::: check
given: D = 0.2 | 0.4 | 0.6; K = 0.05 | 0.15
answer: 2/(1 + sqrt(1 + 4*K/D^2))
tolerance: 0.5%

## A buck runs in DCM at D = {D} with K = {K}. What's its conversion ratio?

::: right
Right. $2/(1 + \sqrt{1 + 4K/D^2})$ = {answer}, above the CCM value D.
:::

::: misses
- [D] That's the CCM ratio; check $K < 1 - D$ first.
- [any] Not yet. Use the DCM formula.
:::
:::

::: check
given: D = 0.3 | 0.5 | 0.7; K = 0.01 | 0.03
answer: (1 + sqrt(1 + 4*D^2/K))/2
tolerance: 0.5%

## A boost runs in DCM at D = {D} with K = {K}. What's its conversion ratio?

::: right
Right. $(1 + \sqrt{1 + 4D^2/K})/2$ = {answer}.
:::

::: misses
- [1/(1 - D)] That's the CCM ratio.
- [any] Not yet. Use the boost's DCM formula.
:::
:::

::: check
given: D = 0.2 | 0.35 | 0.5; K = 0.04 | 0.1
answer: D/sqrt(K)
tolerance: 0.5%

## A buck-boost runs in DCM at D = {D} with K = {K}. What's the magnitude of its conversion ratio?

::: right
Right. $D/\sqrt{K}$ = {answer}.
:::

::: misses
- [D/(1 - D)] That's the CCM ratio.
- [any] Not yet. $|M| = D/\sqrt{K}$.
:::
:::

::: check
given: L = 10 | 47; f = 100 | 300; D = 0.3 | 0.5 | 0.7
answer: 2*L*1e-6*f*1e3/(D*(1 - D)^2)
unit: Ω
tolerance: 0.5%

## A boost has L = {L} µH at {f} kHz and D = {D}. Above what load resistance does it enter DCM?

::: right
Right. $R_\text{crit} = 2Lf_s/(D(1 - D)^2)$ = {answer} Ω.
:::

::: misses
- [2*L*1e-6*f*1e3/(1 - D)] That's the buck's boundary.
- [any] Not yet. $K_\text{crit} = D(1 - D)^2$ for the boost.
:::
:::

::: check
kind: parts
given: L = 10 | 33; f = 100 | 400; R = 50 | 200 | 500; D = 0.2 | 0.4

## A buck-boost with L = {L} µH switches at {f} kHz into {R} Ω at D = {D}.

::: part
answer: 2*L*1e-6*f*1e3/R
tolerance: 0.5%

### What is K?

::: misses
- [any] $2L/(RT_s)$.
:::
:::

::: part
answer: D/sqrt(2*L*1e-6*f*1e3/R)*step((1 - D)^2 - 2*L*1e-6*f*1e3/R) + D/(1 - D)*step(2*L*1e-6*f*1e3/R - (1 - D)^2)
tolerance: 0.5%

### What is the magnitude of its conversion ratio?

::: misses
- [any] $D/\sqrt K$ in DCM, $D/(1 - D)$ in CCM.
:::
:::
:::

::: check
kind: derivation
vars: D = 0.1..0.9, K = 0.001..0.2

## A buck runs in DCM at duty cycle D with parameter K.

::: step
answer: 2/(1 + sqrt(1 + 4*K/D^2))

### What is its conversion ratio?
:::

::: step
answer: 1 - D

### What K marks the CCM boundary?
:::

::: right
Right. In DCM the ratio depends on the load through K, which is what makes light-load regulation different.
:::
:::

::: explain
## Why does a buck converter's output rise at light load in DCM when the duty cycle is held fixed?

::: model
In continuous conduction the inductor is connected either to the input or to ground for the whole period, and volt-second balance forces the output to $DV_g$. In DCM there's a third interval in which the inductor current is zero, so the inductor has no voltage across it and the switch node floats up to the output voltage. That interval removes some of the time during which the output was being pulled down toward ground, so the average voltage at the switch node, and hence the output, rises above $DV_g$. The lighter the load, the longer the idle interval and the higher the output, approaching $V_g$ at no load.
:::
:::

::: practice

::: check
given: L = 6.8 | 33; f = 150 | 600; R = 2 | 20
answer: 2*L*1e-6*f*1e3/R
tolerance: 0.5%

## K for L = {L} µH, {f} kHz, R = {R} Ω?

::: misses
- [any] $2Lf_s/R$.
:::
:::

::: check
given: D = 0.15 | 0.45; K = 0.02 | 0.2
answer: 2/(1 + sqrt(1 + 4*K/D^2))
tolerance: 0.5%

## Buck DCM ratio: D = {D}, K = {K}?

::: misses
- [any] $2/(1 + \sqrt{1 + 4K/D^2})$.
:::
:::

::: check
given: L = 3.3 | 15; f = 250 | 1000; D = 0.25 | 0.6
answer: 2*L*1e-6*f*1e3/(1 - D)
unit: Ω
tolerance: 0.5%

## Buck critical load: L = {L} µH, {f} kHz, D = {D}?

::: misses
- [any] $2Lf_s/(1 - D)$.
:::
:::
:::