S11 · Lesson 46 · Electromagnetic interference in converters

The spectrum of a trapezoidal switching waveform and its two corners, conducted-emission limits and the LISN, differential-mode and common-mode noise paths, sizing an input filter from the attenuation needed, and common-mode chokes

A switching converter that works perfectly on the bench can still be illegal to sell. Its switch node swings hundreds of volts in nanoseconds, and the harmonics of that edge leak back onto the power line and radiate from cables. Regulations (CISPR 32 for most electronics) cap the noise a product may put on the line between 150 kHz and 30 MHz, measured through a standard network. This lesson finds where the noise comes from and how much filtering it takes.

  • The envelope of a switch node's spectrum: a trapezoid swinging 400 V at 50% duty, in dB above 1 µV. It's flat up to 1/πτ, falls 20 dB per decade up to 1/πtr, then 40 dB per decade.
  • Slowing the edges (larger tr) pulls the second corner down and cuts the high-frequency noise, at the cost of switching loss. Raising the switching frequency moves the first corner up.
  • The dashed line is CISPR 32's class B quasi-peak limit for 0.5 to 5 MHz, 56 dBµV. The gap between it and the envelope is what the input filter and the layout must make up.

Predict

A converter's switch node swings 400 V in 20 ns and has 50 pF of capacitance to a grounded heat sink. What current does each edge push into the ground?

Name it

The trapezoid's spectrum

A trapezoidal pulse train of amplitude V, pulse width τ and rise time tr has harmonics bounded by an envelope that starts at 2Vτ/Ts, breaks down at f1=1/πτ to fall 20 dB per decade, and breaks again at f2=1/πtr to fall 40 dB per decade. For a single harmonic n of a 0-to-V pulse train with duty D, the amplitude is 2Vnπ|sin⁡(nπD)|.

Measuring conducted noise

A LISN (line impedance stabilization network) puts a defined 50 Ω between each power line and ground across the band, so measurements are repeatable. Levels are in dBµV, 20log10⁡(V/1μV). CISPR 32 class B (homes) allows 66 falling to 56 dBµV quasi-peak from 150 to 500 kHz, 56 up to 5 MHz and 60 up to 30 MHz; average limits are 10 dB lower.

Two noise paths

  • Differential mode (DM): the converter's pulsing input current flows out on one line and back on the other. An LC filter across the lines removes it.
  • Common mode (CM): the switch node's Cdv/dt into a heat sink or chassis returns through ground and both lines together. A common-mode choke (two windings on one core, cancelling the DM current's flux) plus Y capacitors to ground removes it.

Sizing a filter

A second-order LC filter falls 40 dB per decade beyond its corner. If a harmonic at frequency f needs A dB of attenuation, the corner must be at most

fc=f⋅10−A/40

and then L=1/((2πfc)2C). The filter must also be damped so it doesn't destabilize the converter (lesson 20).

Worked example

Find the spectrum's corners for a 400 V, 100 kHz, 50% switch node with 20 ns edges, and the effect of slowing them to 40 ns.

Show the solution
  1. Corner frequencies. With τ = 5 µs: f1=1π×5μs=63.7kHzf2=1π×20 ns=15.9MHz
  2. Envelope at 30 MHz. E=172.04−53.47−6.58=112.0dBμV
  3. With 40 ns edges. f2 drops to 7.96 MHz and the envelope at 30 MHz to 106.8 dBµV, 5.2 dB less.
  4. Where slower edges help. Mostly above 10 MHz, which is where radiated emissions live.

Answer the corners are at 63.7 kHz and 15.9 MHz; slowing the edges to 40 ns moves the upper one to 7.96 MHz and lowers the envelope at 30 MHz by 5.2 dB, to 106.8 dBµV.

Worked example

A converter's 200 kHz harmonic is 60 dB over the limit. Size an LC filter with a 10 µF capacitor.

Show the solution
  1. Filter corner. fc=200 kHz×10−60/40=6.32kHz
  2. Inductor. L=1(2π×6.32 kHz)2×10μF=63μH
  3. Choosing the switching frequency. A higher switching frequency would push the first harmonic up and let the corner rise; that's one reason designers often pick a switching frequency just under 150 kHz, so the fundamental stays below the band and the first harmonic measured is the second, near 300 kHz.

Answer the corner must sit at 6.32 kHz, so L = 63 µH.

Worked example

A switch node swings 400 V with 10 ns edges at 100 kHz and 50% duty, and the switch's tab has 50 pF to a grounded heat sink. What common-mode current flows, and what does the LISN see at the 3rd harmonic?

Show the solution
  1. Current during each edge. i=Cdv/dt=50 pF×400 V/10 ns=2A
  2. Harmonic by harmonic. The switch node's odd harmonics have amplitude 2V/nπ, and the capacitance passes ωC times that, so at 300 kHz: I3=84.9V×2π×300 kHz×50 pF=8.0mA
  3. Every odd harmonic. Every odd harmonic below the edges' corner gives the same 8.0 mA, because the capacitor's admittance rises as fast as the harmonics fall.
  4. What the LISN sees. Returning through the LISN's two 50 Ω arms in parallel, the current develops V=8.0mA×25Ω=0.20V peak, 0.14 V RMS: 103 dBµV, more than 40 dB above the class B limit near 300 kHz.
  5. The fix. A common-mode choke and Y capacitors must supply that attenuation, or the heat sink can be tied to the switch's DC return instead of to chassis.

Answer 2 A flows during each edge. At the 3rd harmonic 8.0 mA flows, and the LISN sees 0.14 V RMS (103 dBµV), more than 40 dB over the class B limit.

Check

A LISN measures 3 mV at one frequency. What's that in dBµV?

Check

A switch node's edges take 10 ns. Above what frequency does its spectrum fall 40 dB per decade?

Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.

Check

A switch node with 50 pF to chassis swings 48 V in 50 ns. What common-mode current flows during the edge?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A harmonic at 200 kHz needs 40 dB of attenuation from a second-order LC filter. Where must the filter's corner be?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

Check

An input filter needs a 10 kHz corner with a 2.2 µF capacitor. What inductance?

Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.

Check

A switch node swings from 0 to 48 V at duty cycle 0.3. What's the amplitude of its harmonic number 3?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

An input filter must attenuate 150 kHz by 40 dB, using a 10 µF capacitor.

(a)

Where must its corner be?

Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.

(b)

What inductance does that need?

Check

A switch node swings from 0 to V at duty D with period T and rise time r.

Step 1

What is the amplitude of harmonic n?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a common-mode choke stop common-mode noise without saturating from the converter's load current?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.