title: Inductor design
heading: Designing a filter inductor from its required inductance, peak and RMS currents, maximum flux density and allowed copper loss, using the core geometry constant Kg to choose the core, then the turns, gap and wire size
eyebrow: S11 · Lesson 25 · Inductor design
xp: 50
---

::: hook
An inductor design has to satisfy four requirements at once: the right inductance, a peak flux density below saturation, windings that physically fit in the core's window, and copper loss within budget. Each involves the core's cross-section, its window area and the length of a turn, and they pull against each other: more turns give inductance but take window space and add resistance. Erickson's geometrical constant $K_g$ combines all four into one number that says whether a core is big enough before any turns are counted.
:::

::: play
- The copper loss of an inductor design against the number of turns, for a fixed core (cross-section 1 cm², window 1.5 cm², 5 cm mean turn) carrying 8 A RMS with a fill factor of 0.5.
- Copper loss rises as $N^2$: each turn adds length, and the wire must get thinner to fit.
- The dashed line marks the fewest turns that keep the flux at 0.25 T when the inductor carries its 8.5 A peak as 47 µH: about 16. That's the design point.
:::

```sim plot
view: graph
x: N = 5..40
y: P = 0..2 W
slider: I = 4..12 = 8 A
plot: 1.724e-8*N^2*0.05*I^2/(0.5*1.5e-4) | samples: 300 | label: copper loss
marker: x = 47e-6*8.5/(0.25*1e-4) | label: minimum turns for 0.25 T
readout: loss at 16 turns, W = 1.724e-8*256*0.05*I^2/(0.5*1.5e-4) | digits: 3
```

::: predict
## A 47 µH inductor carries a peak of 8.5 A on a core with 1 cm² of cross-section, and the flux density must stay below 0.25 T. How many turns does it need?

- [ ] 4
- [x] 16
- [ ] 64
- [ ] It depends only on the gap

::: reveal
The peak flux is $LI_\text{max} = N\Phi = NB_\text{max}A_c$, so $N = LI_\text{max}/(B_\text{max}A_c) = 47\,\mu\text{H} \times 8.5/(0.25 \times 10^{-4})$ = 15.98: 16 turns. The gap is then chosen to give exactly 47 µH with those turns.
:::
:::

::: nameit
## Four constraints

1. **Flux density:** $N = \dfrac{LI_\text{max}}{B_\text{max}A_c}$.
2. **Inductance:** with the gap dominating, $L = \mu_0N^2A_c/g$, so $g = \dfrac{\mu_0LI_\text{max}^2}{B_\text{max}^2A_c}$.
3. **Window:** N turns of wire area $A_w$ fit if $NA_w \le K_uW_A$, with fill factor $K_u$ (often 0.3 to 0.5) and window area $W_A$.
4. **Copper loss:** $P_{cu} = I_\text{rms}^2\rho\frac{N(\text{MLT})}{A_w}$ with MLT the mean length per turn.

## The geometrical constant

Combining them eliminates N, g and $A_w$:

$$K_g = \frac{A_c^2W_A}{\text{MLT}} \ge \frac{\rho L^2I_\text{max}^2I_\text{rms}^2}{B_\text{max}^2P_{cu}K_u}$$

The left side depends only on the core, so a catalog of $K_g$ values picks the smallest core that can meet the specification.

## The procedure

Compute the required $K_g$, choose a core with a larger one, then N from the flux limit, the gap from the inductance, the wire from the window, and check the loss.
:::

::: example
## Design a 47 µH inductor for 8.5 A peak and 8 A RMS, with $B_\text{max}$ = 0.25 T, 1 W of copper loss and $K_u$ = 0.5.

::: solution
1. **Required $K_g$.**
   $$\begin{aligned} K_g &= \frac{\rho L^2I_\text{max}^2I_\text{rms}^2}{B_\text{max}^2P_{cu}K_u} \\ &= \frac{(1.724 \times 10^{-8})(47\,\mu\text{H})^2}{0.25^2 \times 1 \times 0.5} \\ &\quad \times 8.5^2 \times 8^2 \\ &= 5.6 \times 10^{-12}\ \text{m}^5 \\ &= 0.056\ \text{cm}^5 \end{aligned}$$
2. **Choose a core.** A core with $A_c$ = 1 cm², $W_A$ = 1.5 cm² and MLT = 5 cm has
   $$\begin{aligned} K_g &= \frac{A_c^2W_A}{\text{MLT}} \\ &= 0.3\ \text{cm}^5 \end{aligned}$$
   plenty.
3. **Turns and gap.**
   $$\begin{aligned} N &= 16 \\ g &= \frac{\mu_0LI_\text{max}^2}{B_\text{max}^2A_c} \\ &= 0.68\ \text{mm} \end{aligned}$$
4. **Wire.** The wire area can be up to
   $$\begin{aligned} A_w &= \frac{0.5 \times 1.5\ \text{cm}^2}{16} \\ &= 4.69\ \text{mm}^2 \end{aligned}$$
   for a resistance of 2.94 mΩ.
5. **Copper loss.**
   $$\begin{aligned} P_{cu} &= 8^2 \times 2.94\ \text{m}\Omega \\ &= 0.19\ \text{W} \end{aligned}$$
   well under budget because the core is oversized.

**Answer:** the design needs $K_g$ = 0.056 cm⁵; on a 0.3 cm⁵ core it takes 16 turns, a 0.68 mm gap and 4.69 mm² wire, and loses 0.19 W in the copper.
:::
:::

::: example
## What changes if the RMS current doubles?

::: solution
1. **Required $K_g$.** It grows by four:
   $$\begin{aligned} K_g &= 4 \times 0.0564\ \text{cm}^5 \\ &= 0.23\ \text{cm}^5 \end{aligned}$$
   still within the chosen core's 0.3 cm⁵.
2. **Turns and gap.** N and the gap are set by the peak current, which hasn't changed.
3. **Copper loss.** It quadruples:
   $$\begin{aligned} P_{cu} &= 4 \times 0.188\ \text{W} \\ &= 0.75\ \text{W} \end{aligned}$$

**Answer:** the same core still works (0.23 cm⁵ needed against 0.3 cm⁵), with the same turns and gap, but the copper loss quadruples to 0.75 W.
:::
:::

::: example
## A 47 µH inductor carries 8.5 A peak. How much energy does its gap store, and how long must a gap across 1 cm² be to hold it at 0.25 T?

::: solution
1. **Stored energy.**
   $$\begin{aligned} E &= \tfrac12LI^2 \\ &= \tfrac12 \times 47 \times 10^{-6} \times 8.5^2 \\ &= 1.70\ \text{mJ} \end{aligned}$$
   nearly all in the gap.
2. **Energy density in the gap.**
   $$\begin{aligned} w &= \frac{B^2}{2\mu_0} \\ &= \frac{0.0625}{2\mu_0} \\ &= 24\,900\ \text{J/m}^3 \end{aligned}$$
3. **Gap length.** That needs 68 mm³, so across $A_c$ = 100 mm²:
   $$\begin{aligned} g &= \frac{68\ \text{mm}^3}{100\ \text{mm}^2} \\ &= 0.68\ \text{mm} \end{aligned}$$
   matching $g = \mu_0LI^2/(B^2A_c)$.
4. **The ferrite.** The ferrite itself, with its high permeability, stores almost nothing.

**Answer:** the gap stores 1.70 mJ, which takes a 0.68 mm gap across 1 cm².
:::
:::

::: check
given: L = 10 | 47 | 220; I = 3 | 8 | 15; B = 0.2 | 0.3; A = 0.5 | 1 | 2
answer: L*1e-6*I/(B*A*1e-4)
tolerance: 0.5%

## An inductor of {L} µH carries a peak of {I} A on a {A} cm² core with $B_\text{max}$ = {B} T. How many turns does the flux limit require (before rounding)?

::: right
Right. $LI_\text{max}/(B_\text{max}A_c)$ = {answer}.
:::

::: misses
- [any] Not yet. $NB_\text{max}A_c = LI_\text{max}$.
:::
:::

::: check
given: L = 10 | 47 | 220; I = 3 | 8 | 15; B = 0.2 | 0.3; A = 0.5 | 1 | 2
answer: 4*pi*1e-7*L*1e-6*I^2/(B^2*A*1e-4)*1000
unit: mm
tolerance: 0.5%

## For the same inductor, what gap gives exactly {L} µH?

::: right
Right. $\mu_0LI_\text{max}^2/(B_\text{max}^2A_c)$ = {answer} mm.
:::

::: misses
- [any] Not yet. Combine $L = \mu_0N^2A_c/g$ with the turns from the flux limit.
:::
:::

::: check
given: L = 22 | 100; I = 5 | 12; R = 4 | 10; B = 0.25 | 0.35; P = 0.5 | 2; K = 0.3 | 0.5
answer: 1.724e-8*(L*1e-6)^2*I^2*R^2/(B^2*P*K)*1e10
unit: cm^5
tolerance: 1%

## What $K_g$ is needed for {L} µH at {I} A peak and {R} A RMS, $B_\text{max}$ = {B} T, {P} W of copper loss and $K_u$ = {K}?

::: right
Right. $\rho L^2I_\text{max}^2I_\text{rms}^2/(B_\text{max}^2P_{cu}K_u)$ = {answer} cm⁵.
:::

::: misses
- [any] Not yet. Use ρ = 1.724 × 10⁻⁸ Ω·m and convert m⁵ to cm⁵ (× 10¹⁰).
:::
:::

::: check
given: a = 0.4 | 1.5 | 2.5; w = 0.6 | 1.5 | 4; m = 3 | 6 | 10
answer: a^2*w/m
unit: cm^5
tolerance: 0.5%

## A core has $A_c$ = {a} cm², $W_A$ = {w} cm² and MLT = {m} cm. What's its $K_g$?

::: right
Right. $A_c^2W_A/\text{MLT}$ = {answer} cm⁵.
:::

::: misses
- [a*w/m] $A_c$ is squared.
- [any] Not yet. $K_g = A_c^2W_A/\text{MLT}$.
:::
:::

::: check
given: N = 10 | 30; m = 4 | 8; K = 0.4 | 0.5; w = 1 | 2.5; I = 3 | 10
answer: 1.724e-8*N*m*1e-2*I^2/(K*w*1e-4/N)
unit: W
tolerance: 0.5%

## {N} turns of the largest wire that fits ($K_u$ = {K}, $W_A$ = {w} cm²) with MLT = {m} cm carry {I} A RMS. What's the copper loss?

::: right
Right. $I^2\rho N(\text{MLT})/A_w$ with $A_w = K_uW_A/N$: {answer} W.
:::

::: misses
- [any] Not yet. Wire area from the window, then resistance.
:::
:::

::: check
given: L = 33 | 150; I = 4 | 10; N = 12 | 30; A = 0.8 | 1.6
answer: L*1e-6*I/(N*A*1e-4)
unit: T
tolerance: 0.5%

## A {L} µH inductor with {N} turns on a {A} cm² core carries {I} A peak. What's its peak flux density?

::: right
Right. $LI/(NA_c)$ = {answer} T.
:::

::: misses
- [any] Not yet. $N\Phi = Li$.
:::
:::

::: check
kind: parts
given: L = 10 | 47 | 220; I = 3 | 8 | 15; B = 0.2 | 0.3; A = 0.5 | 1 | 2

## An inductor of {L} µH carries {I} A peak on a core of {A} cm² at $B_\max$ = {B} T.

::: part
answer: 0.5*L*1e-6*I^2*1e3
unit: mJ
tolerance: 0.5%

### How much energy does it store at peak?

::: misses
- [any] $\frac12LI^2$.
:::
:::

::: part
answer: 4*pi*1e-7*L*1e-6*I^2/(B^2*A*1e-4)*1e3
unit: mm
tolerance: 0.5%

### What gap holds it at $B_\max$?

::: misses
- [any] $g = \mu_0LI^2/(B_\max^2A_c)$.
:::
:::
:::

::: check
kind: derivation
vars: L = 0.000001..0.001, I = 0.5..30, B = 0.1..0.4, A = 0.00001..0.0005

## An inductor L at peak current I is designed for $B_\max$ = B on core area A (SI units).

::: step
answer: L*I/(B*A)

### How many turns?
:::

::: step
answer: 4*pi*1e-7*L*I^2/(B^2*A)

### What gap?
:::

::: step
answer: L*I^2/2

### What energy does the gap store?
:::

::: right
Right. The stored energy fixes the gap's volume: $g A_c = 2E\mu_0/B^2$.
:::
:::

::: explain
## Why does the required core size grow with the square of the inductance times the current?

::: model
An inductor stores energy $\frac{1}{2}LI^2$, and that energy has to fit in the core's magnetic field, mostly in the gap, at a flux density below saturation. Larger $LI$ means more flux linkage, which needs either more turns or more core cross-section at the limited flux density; more turns need more window area and longer total wire, which raises the copper loss for a given wire size. The $K_g$ constraint captures that trade: halving the copper-loss budget or the allowed flux density forces a proportionally bigger core, and doubling $LI$ needs four times the $K_g$. That's why higher switching frequencies, which shrink the needed inductance, shrink the magnetics so effectively.
:::
:::

::: practice

::: check
given: L = 15 | 100; I = 4 | 12; B = 0.25 | 0.3; A = 0.6 | 1.5
answer: L*1e-6*I/(B*A*1e-4)
tolerance: 0.5%

## Turns for the flux limit: {L} µH, {I} A, {B} T, {A} cm²?

::: misses
- [any] $LI/(BA_c)$.
:::
:::

::: check
given: a = 0.6 | 1.8; w = 0.9 | 3; m = 4 | 9
answer: a^2*w/m
unit: cm^5
tolerance: 0.5%

## Core $K_g$: {a} cm², {w} cm², MLT {m} cm?

::: misses
- [any] $A_c^2W_A/\text{MLT}$.
:::
:::

::: check
given: L = 22 | 68; I = 5 | 9; B = 0.25 | 0.35; A = 0.8 | 1.5
answer: 4*pi*1e-7*L*1e-6*I^2/(B^2*A*1e-4)*1000
unit: mm
tolerance: 0.5%

## Gap: {L} µH, {I} A peak, {B} T, {A} cm²?

::: misses
- [any] $\mu_0LI^2/(B^2A_c)$.
:::
:::
:::