S11 · Lesson 12 · Multiphase and interleaved converters
Splitting one converter into N phases shifted in time: ripple cancellation and its exact formula, N times the ripple frequency, smaller capacitors, current sharing between phases, and why processors are powered this way
A processor's core needs around a volt at well over a hundred amperes, changing in microseconds. One buck converter could do it only with a huge inductor and a bank of capacitors. Instead, voltage regulators use several bucks in parallel, each switching a fraction of a period after the one before. Their ripple currents partly cancel, the output sees N times the switching frequency, each phase carries a manageable share of the current, and the load step is spread across phases that can respond in turn.
- The curve is the total output ripple of N interleaved buck phases, relative to the ripple scale, against duty cycle: with , compared with a single phase's .
- The ripple vanishes whenever D is a multiple of 1/N: the phases' rising and falling slopes cancel exactly.
- Between those points it peaks, but far below a single phase's ripple.
Predict
Two interleaved buck phases run at D = 0.5. What is the total output ripple current?
At D = 0.5, while one phase's current rises, the other's falls at exactly the same rate, so their sum is constant. With N phases the cancellation is perfect at D = 1/N, 2/N and so on. Away from those points it's partial, and the combined ripple runs at N times the switching frequency, which helps the output capacitor twice over.
Name it
Phase shifting
N identical converters share the load, each switching after the previous one. Each phase's inductor ripple is that of a single converter, for a buck, but the sum of N shifted triangles is a smaller triangle at frequency .
The cancellation formula
For N interleaved bucks with , the total output current ripple is
which equals the single-phase for N = 1 and reaches zero at D = k/N. For two phases with D < 0.5 it's times one phase's ripple.
Consequences
- Output capacitor: the ripple it filters is smaller and N times faster, so .
- Input capacitor: the input current pulses also interleave, cutting its RMS ripple current.
- Transient response: each phase can use a small inductance (large ripple per phase is acceptable because it cancels), so the total current can slew quickly.
- Thermal spreading: losses split across N sets of devices and inductors.
Current sharing
Phases with slightly different resistances or timing would share current unevenly. With a common duty cycle, the DC currents divide inversely with each phase's resistance; current-mode control (lesson 23) or active current balancing forces equal shares.
Worked example
A four-phase regulator makes 1.2 V from 12 V (D = 0.1) at 500 kHz with 0.2 µH per phase. Compare the ripple of one phase with the total.
Show the solution
- Ripple scale.
- One phase. peak to peak.
- The total. With N = 4 and D = 0.1, m = 0, so at 2 MHz.
- What it buys. Four phases carrying 30 A each with 10.8 A ripple deliver 120 A with only 7.2 A of output ripple at four times the frequency.
Answer each phase ripples by 10.8 A peak to peak, while the total ripples by only 7.2 A, at 2 MHz.
Worked example
Two phases interleave at D = 0.25. By how much does interleaving cut the output ripple current, and the capacitor's voltage ripple?
Show the solution
- Current ripple. of one phase's.
- Voltage ripple. The capacitor sees it at twice the frequency, so with the same capacitor a third of one phase's voltage ripple.
- Or a smaller capacitor. The capacitor could instead be cut to a third for the same ripple.
Answer interleaving cuts the ripple current to 0.67 of one phase's and the capacitor's voltage ripple to a third.
Worked example
Two phases share 40 A with a common duty cycle. Their inductors' resistances are 1.0 and 1.2 mΩ, and all else is equal. How do they share?
Show the solution
- How they divide. With the same average voltage driving both inductors into the same output, the currents divide inversely with resistance:
- The imbalance. A 20% resistance mismatch gives a 9% current imbalance either way from the mean.
- The fix. Current-mode control, which commands each phase's current directly, removes it.
Answer the 1.0 mΩ phase carries 21.8 A and the 1.2 mΩ phase 18.2 A, 9% either way from the mean.
Check
3 interleaved buck phases run at D = 0.08.
(a)
What fraction of one phase's ripple is the total output ripple?
(b)
How many times the switching frequency is the total ripple?
Check
A 4-phase regulator makes 1.2 V from 12 V with 0.15 µH per phase at 600 kHz.
(a)
What is each phase's ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the total output ripple?
Check
Two buck phases interleave at D = 0.2. One phase alone would ripple 4 A at 500 kHz; the output has 470 µF.
(a)
What is the total ripple current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What output voltage ripple does the capacitor allow?
Check
Two phases with inductor resistances 0.8 and 1.5 mΩ share 60 A at a common duty cycle.
(a)
What does the first carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
3 phases interleave.
(a)
At what smallest nonzero duty cycle does the output ripple cancel completely?
(b)
How far apart are the phases' switching instants, in degrees of a period?
Check
A 100 W, 1 V output is split among 2 phase(s), each with 5 mΩ of conduction resistance.
(a)
What is the total conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Why can interleaved phases each use a small inductance with large ripple, when a single-phase converter can't?
Check
Two buck phases interleave at duty D < 0.5; one phase ripples d at frequency f; the output capacitance is C.
Step 1
What is the total ripple current?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What output voltage ripple?
Check
Write total_ripple(N, D, Vo, L, f): sample 20 000 points of the summed inductor currents of N interleaved bucks (each a triangle with rising slope for and falling slope , phase k delayed by of a period) over one period and return the peak-to-peak.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Explain why
Why are processor power supplies built from many interleaved phases rather than one large converter?
A processor needs very high current at low voltage and changes its demand within microseconds. One converter would need a single large inductor to keep its ripple tolerable, which would slow its response to load steps, and a large bank of output capacitors to hold the voltage meanwhile. Splitting the job into several phases that switch in turn lets each use a small inductor with large ripple, because the ripples cancel at the output, and the remaining ripple appears at a multiple of the switching frequency where capacitors filter it easily. The current and the losses are shared across many devices, which spreads the heat, and with more phases active the total current can change quickly, so the converter keeps up with the load.
Practice
Keep practicing
9 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.