title: Multiphase and interleaved converters
heading: Splitting one converter into N phases shifted in time: ripple cancellation and its exact formula, N times the ripple frequency, smaller capacitors, current sharing between phases, and why processors are powered this way
eyebrow: S11 · Lesson 12 · Multiphase and interleaved converters
xp: 50
---

::: hook
A processor's core needs around a volt at well over a hundred amperes, changing in microseconds. One buck converter could do it only with a huge inductor and a bank of capacitors. Instead, voltage regulators use several bucks in parallel, each switching a fraction of a period after the one before. Their ripple currents partly cancel, the output sees N times the switching frequency, each phase carries a manageable share of the current, and the load step is spread across phases that can respond in turn.
:::

::: play
- The curve is the total output ripple of N interleaved buck phases, relative to the ripple $V/(Lf_s)$ scale, against duty cycle: $K(N, D) = N\frac{(D - m/N)((m + 1)/N - D)}{D}$ with $m = \lfloor ND\rfloor$, compared with a single phase's $1 - D$.
- The ripple vanishes whenever D is a multiple of 1/N: the phases' rising and falling slopes cancel exactly.
- Between those points it peaks, but far below a single phase's ripple.
:::

```sim plot
view: graph
x: D = 0.02..0.98
y: K = 0..1
slider: N = 1..6 = 2
plot: N*(D - floor(N*D)/N)*((floor(N*D) + 1)/N - D)/D | label: N interleaved phases
plot: 1 - D | dashed | label: one phase
```

::: predict
## Two interleaved buck phases run at D = 0.5. What is the total output ripple current?

- [ ] Half of one phase's
- [x] Zero
- [ ] The same as one phase's
- [ ] Twice one phase's

::: reveal
At D = 0.5, while one phase's current rises, the other's falls at exactly the same rate, so their sum is constant. With N phases the cancellation is perfect at D = 1/N, 2/N and so on. Away from those points it's partial, and the combined ripple runs at N times the switching frequency, which helps the output capacitor twice over.
:::
:::

::: nameit
## Phase shifting

N identical converters share the load, each switching $T_s/N$ after the previous one. Each phase's inductor ripple is that of a single converter, $\Delta I = V(1 - D)/(Lf_s)$ for a buck, but the sum of N shifted triangles is a smaller triangle at frequency $Nf_s$.

## The cancellation formula

For N interleaved bucks with $m = \lfloor ND\rfloor$, the total output current ripple is
$$\Delta I_\text{total} = \frac{V}{Lf_s}\cdot\frac{N(D - m/N)\left(\frac{m + 1}{N} - D\right)}{D}$$
which equals the single-phase $\frac{V(1 - D)}{Lf_s}$ for N = 1 and reaches zero at D = k/N. For two phases with D < 0.5 it's $(1 - 2D)/(1 - D)$ times one phase's ripple.

## Consequences

- **Output capacitor**: the ripple it filters is smaller and N times faster, so $\Delta V = \Delta I_\text{total}/(8Nf_sC)$.
- **Input capacitor**: the input current pulses also interleave, cutting its RMS ripple current.
- **Transient response**: each phase can use a small inductance (large ripple per phase is acceptable because it cancels), so the total current can slew quickly.
- **Thermal spreading**: losses split across N sets of devices and inductors.

## Current sharing

Phases with slightly different resistances or timing would share current unevenly. With a common duty cycle, the DC currents divide inversely with each phase's resistance; current-mode control (lesson 23) or active current balancing forces equal shares.
:::

::: example
## A four-phase regulator makes 1.2 V from 12 V (D = 0.1) at 500 kHz with 0.2 µH per phase. Compare the ripple of one phase with the total.

::: solution
1. **Ripple scale.**
   $$\begin{aligned} \frac{V}{Lf_s} &= \frac{1.2}{0.2\ \mu\text{H} \times 500\text{ kHz}} \\ &= 12\ \text{A} \end{aligned}$$
2. **One phase.**
   $$\begin{aligned} \Delta I_\text{phase} &= 12 \times 0.9 \\ &= 10.8\ \text{A} \end{aligned}$$
   peak to peak.
3. **The total.** With N = 4 and D = 0.1, m = 0, so
   $$\begin{aligned} \Delta I &= 12 \times \frac{4 \times 0.1 \times 0.15}{0.1} \\ &= 7.2\ \text{A} \end{aligned}$$
   at 2 MHz.
4. **What it buys.** Four phases carrying 30 A each with 10.8 A ripple deliver 120 A with only 7.2 A of output ripple at four times the frequency.

**Answer:** each phase ripples by 10.8 A peak to peak, while the total ripples by only 7.2 A, at 2 MHz.
:::
:::

::: example
## Two phases interleave at D = 0.25. By how much does interleaving cut the output ripple current, and the capacitor's voltage ripple?

::: solution
1. **Current ripple.**
   $$\begin{aligned} \frac{1 - 2D}{1 - D} &= \frac{0.5}{0.75} \\ &= 0.67 \end{aligned}$$
   of one phase's.
2. **Voltage ripple.** The capacitor sees it at twice the frequency, so with the same capacitor
   $$\Delta V = \frac{\Delta I}{8 \times 2f_sC}$$
   a third of one phase's voltage ripple.
3. **Or a smaller capacitor.** The capacitor could instead be cut to a third for the same ripple.

**Answer:** interleaving cuts the ripple current to 0.67 of one phase's and the capacitor's voltage ripple to a third.
:::
:::

::: example
## Two phases share 40 A with a common duty cycle. Their inductors' resistances are 1.0 and 1.2 mΩ, and all else is equal. How do they share?

::: solution
1. **How they divide.** With the same average voltage driving both inductors into the same output, the currents divide inversely with resistance:
   $$\begin{aligned} I_1 &= 40 \times \frac{1.2}{2.2} \\ &= 21.8\ \text{A} \\ I_2 &= 40 - 21.8 \\ &= 18.2\ \text{A} \end{aligned}$$
2. **The imbalance.** A 20% resistance mismatch gives a 9% current imbalance either way from the mean.
3. **The fix.** Current-mode control, which commands each phase's current directly, removes it.

**Answer:** the 1.0 mΩ phase carries 21.8 A and the 1.2 mΩ phase 18.2 A, 9% either way from the mean.
:::
:::

::: check
kind: parts
given: N = 2 | 3 | 4 | 6; D = 0.08 | 0.15 | 0.3

## {N} interleaved buck phases run at D = {D}.

::: part
answer: N*(D - floor(N*D)/N)*((floor(N*D) + 1)/N - D)/D/(1 - D)
tolerance: 0.5%

### What fraction of one phase's ripple is the total output ripple?

::: misses
- [1/N] Cancellation depends on the duty cycle, not just N.
- [any] $K(N, D)/(1 - D)$.
:::
:::

::: part
answer: N
tolerance: 0
unit: times

### How many times the switching frequency is the total ripple?

::: misses
- [any] N.
:::
:::
:::

::: check
kind: parts
given: V = 0.9 | 1.2 | 1.8; g = 12; L = 0.15 | 0.3; f = 300 | 600; N = 2 | 4

## An {N}-phase regulator makes {V} V from {g} V with {L} µH per phase at {f} kHz.

::: part
answer: V*(1 - V/g)/(L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is each phase's ripple?

::: misses
- [any] $V(1 - D)/(Lf_s)$.
:::
:::

::: part
answer: V/(L*1e-6*f*1e3)*N*(V/g - floor(N*V/g)/N)*((floor(N*V/g) + 1)/N - V/g)/(V/g)
unit: A
tolerance: 0.5%

### What is the total output ripple?

::: misses
- [any] $\frac{V}{Lf_s}\cdot\frac{N(D - m/N)((m + 1)/N - D)}{D}$.
:::
:::
:::

::: check
kind: parts
given: D = 0.1 | 0.2 | 0.35; d = 4 | 10; f = 200 | 500; C = 100 | 470

## Two buck phases interleave at D = {D}. One phase alone would ripple {d} A at {f} kHz; the output has {C} µF.

::: part
answer: d*(1 - 2*D)/(1 - D)
unit: A
tolerance: 0.5%

### What is the total ripple current?

::: misses
- [d/2] The cancellation factor is $(1 - 2D)/(1 - D)$.
- [any] $(1 - 2D)/(1 - D)$ times one phase's.
:::
:::

::: part
answer: d*(1 - 2*D)/(1 - D)/(8*2*f*1e3*C*1e-6)*1e3
unit: mV
tolerance: 0.5%

### What output voltage ripple does the capacitor allow?

::: misses
- [d*(1 - 2*D)/(1 - D)/(8*f*1e3*C*1e-6)*1e3] The ripple is at twice the switching frequency.
- [any] $\Delta I_\text{total}/(8 \cdot 2f_sC)$.
:::
:::
:::

::: check
kind: parts
given: I = 30 | 60 | 120; a = 0.8 | 1.0; b = 1.1 | 1.5

## Two phases with inductor resistances {a} and {b} mΩ share {I} A at a common duty cycle.

::: part
answer: I*b/(a + b)
unit: A
tolerance: 0.5%

### What does the first carry?

::: misses
- [I*a/(a + b)] Current divides inversely with resistance.
- [any] $Ib/(a + b)$.
:::
:::
:::

::: check
kind: parts
given: N = 2 | 3 | 4 | 5

## {N} phases interleave.

::: part
answer: 1/N
tolerance: 0.5%

### At what smallest nonzero duty cycle does the output ripple cancel completely?

::: misses
- [any] D = 1/N.
:::
:::

::: part
answer: 360/N
unit: °
tolerance: 0.5%

### How far apart are the phases' switching instants, in degrees of a period?

::: misses
- [any] 360°/N.
:::
:::
:::

::: check
kind: parts
given: P = 100 | 300; n = 2 | 3 | 4; R = 2 | 5

## A {P} W, 1 V output is split among {n} phase(s), each with {R} mΩ of conduction resistance.

::: part
answer: n*(P/n)^2*R*1e-3
unit: W
tolerance: 0.5%

### What is the total conduction loss?

::: misses
- [P^2*R*1e-3] Each phase carries I/n.
- [any] $n(I/n)^2R = I^2R/n$.
:::
:::
:::

::: check
kind: choice

## Why can interleaved phases each use a small inductance with large ripple, when a single-phase converter can't?

- [ ] Small inductors are always better
- [x] The phases' ripples largely cancel at the output, so the capacitor and load see little of them, while each small inductor lets its phase's current change quickly during load steps; the per-phase ripple costs some core and AC loss but not output ripple
- [ ] Interleaving removes inductor losses
- [ ] Each phase switches N times faster

::: misses
- [1] Small inductors raise ripple and its losses.
- [3] Losses remain, per phase.
- [4] Each phase switches at $f_s$; the output ripple is at $Nf_s$.
:::
:::

::: check
kind: derivation
vars: D = 0.05..0.45, d = 0.1..20, f = 10000..2000000, C = 0.000001..0.001

## Two buck phases interleave at duty D < 0.5; one phase ripples d at frequency f; the output capacitance is C.

::: step
answer: d*(1 - 2*D)/(1 - D)

### What is the total ripple current?
:::

::: step
answer: d*(1 - 2*D)/(1 - D)/(16*f*C)

### What output voltage ripple?
:::

::: right
Right. Cancellation and frequency doubling multiply: the voltage ripple falls faster than the current ripple.
:::
:::

::: check
kind: python

## Write `total_ripple(N, D, Vo, L, f)`: sample 20 000 points of the summed inductor currents of N interleaved bucks (each a triangle with rising slope $(V_o/D - V_o)/L$ for $DT_s$ and falling slope $-V_o/L$, phase k delayed by $k/N$ of a period) over one period and return the peak-to-peak.

```python starter
def total_ripple(N, D, Vo, L, f):
    return Vo * (1 - D) / (L * f)
```

```python solution
def total_ripple(N, D, Vo, L, f):
    T = 1 / f
    up = (Vo / D - Vo) / L
    down = Vo / L
    vals = []
    for i in range(20000):
        t = i / 20000
        s = 0.0
        for k in range(N):
            tp = (t - k / N) % 1
            if tp < D:
                s += up * tp * T
            else:
                s += up * D * T - down * (tp - D) * T
        vals.append(s)
    return max(vals) - min(vals)
```

```python tests
import math
K = lambda N, D: N * (D - math.floor(N * D) / N) * ((math.floor(N * D) + 1) / N - D) / D
for N, D in ((1, 0.3), (2, 0.25), (4, 0.1), (3, 0.45)):
    assert abs(total_ripple(N, D, 1.2, 0.2e-6, 5e5) - 12 * K(N, D)) < 0.01, f"N = {N}, D = {D} matches the formula."
assert total_ripple(2, 0.5, 1.2, 0.2e-6, 5e5) < 1e-6, "D = 1/2 with two phases: no ripple."
```

::: right
Right. The sum of shifted triangles is itself a triangle at N times the frequency, which is what the formula describes.
:::
:::

::: explain
## Why are processor power supplies built from many interleaved phases rather than one large converter?

::: model
A processor needs very high current at low voltage and changes its demand within microseconds. One converter would need a single large inductor to keep its ripple tolerable, which would slow its response to load steps, and a large bank of output capacitors to hold the voltage meanwhile. Splitting the job into several phases that switch in turn lets each use a small inductor with large ripple, because the ripples cancel at the output, and the remaining ripple appears at a multiple of the switching frequency where capacitors filter it easily. The current and the losses are shared across many devices, which spreads the heat, and with more phases active the total current can change quickly, so the converter keeps up with the load.
:::
:::

::: practice
::: check
given: D = 0.15 | 0.3; d = 5 | 12
answer: d*(1 - 2*D)/(1 - D)
unit: A
tolerance: 0.5%

## Total ripple of two phases at D = {D}, each rippling {d} A?

::: misses
- [any] $(1 - 2D)/(1 - D)$ times one.
:::
:::

::: check
given: I = 40 | 90; a = 1 | 2; b = 1.3 | 2.5
answer: I*b/(a + b)
unit: A
tolerance: 0.5%

## Current in the {a} mΩ phase of two sharing {I} A (other {b} mΩ)?

::: misses
- [any] Inverse to resistance.
:::
:::

::: check
given: N = 2 | 3 | 4 | 5 | 6 | 8
answer: 1/N
tolerance: 0.5%

## Smallest duty cycle for perfect cancellation with {N} phases?

::: misses
- [any] 1/N.
:::
:::
:::