S11 · Lesson 33 · Inverters and pulse-width modulation

Half-bridge and full-bridge inverters, sinusoidal PWM with a triangular carrier, the modulation index and the fundamental it produces, three-phase voltage-source inverters and third-harmonic injection, switching harmonics, and dead time

Solar panels, batteries and the DC link of every variable-speed motor drive need to make AC: a sine wave of controllable amplitude and frequency. An inverter does it by switching a DC bus to its output at tens of kilohertz with a duty cycle that follows a sine. The output is a stream of pulses, but its average over each switching period traces the sine, and the inductance of a motor or a filter does the averaging. This lesson covers the modulation and how much AC voltage a given DC bus can make.

  • One inverter leg under sinusoidal PWM: the reference msin⁡ωt is compared with a triangular carrier, and the leg's output switches between +1 and −1 (in units of Vdc/2). The spectrum shows a fundamental of exactly m and a cluster of harmonics around the carrier frequency.
  • Raise m above 1 and the reference exceeds the carrier: pulses go missing (overmodulation), adding low-order harmonics.
  • Raising the carrier frequency pushes the harmonics up, where an output filter or the motor's inductance removes them easily.

Predict

A three-phase inverter runs from a 400 V DC bus with sinusoidal PWM at m = 1. What line-to-line RMS voltage can it produce?

Name it

Bridges

A half-bridge leg connects its output to +Vdc/2 or −Vdc/2 about the bus midpoint. A full bridge (H-bridge) uses two legs and can apply +Vdc, −Vdc or zero across the load.

Sinusoidal PWM

Compare a sinusoidal reference of amplitude m (the modulation index) with a triangular carrier of unit amplitude at frequency fc. The leg is high while the reference exceeds the carrier. For m≤1 the fundamental of a half-bridge's output has peak mVdc/2, exactly linear in m; a full bridge gives mVdc. Harmonics cluster around multiples of the frequency ratio mf=fc/f1.

Three phase

Three legs with references 120° apart give line-to-line voltages with RMS

VLL=322mVdc=0.612mVdc

Adding a third harmonic of 1/6 the fundamental to all three references flattens their peaks without affecting the line-to-line voltages, allowing m up to 2/3 = 1.155 and VLL=Vdc/2. Space-vector modulation reaches the same limit.

Dead time

The two switches in a leg must never conduct together, so each turn-on waits a dead time td. During it the load current's direction decides the output, causing an average voltage error of about tdfsVdc that distorts the output at low voltages.

Worked example

What can a full bridge on a 400 V bus deliver at m = 0.8?

Show the solution
  1. Fundamental. V1=0.8×400=320V peak, 226 V RMS.
  2. For 230 V RMS. A 325 V peak needs m=325/400=0.81 at nominal bus.
  3. Margin. A 400 V bus leaves little margin for sag; grid inverters use buses of 400 V and up for this reason.

Answer a fundamental of 320 V peak, 226 V RMS.

Worked example

A 400 V three-phase inverter switches at 10 kHz with 1 µs of dead time. How large is the dead-time voltage error?

Show the solution
  1. Dead-time error. ΔV≈tdfsVdc=1μs×10 kHz×400V=4V per leg, with its sign set by the current's direction.
  2. At a low output voltage. At 20 V, say, for a slowly turning motor, that's a 20% error, which drive controllers compensate.

Answer about 4 V per leg.

Worked example

A full-bridge inverter on a 400 V bus must make 230 V RMS, switching at 20 kHz behind an LC filter with a 2 kHz corner. What modulation index does it need, and how much does the filter attenuate the switching component?

Show the solution
  1. Modulation index. A full bridge's fundamental has peak mVdc, so m=2302400=0.813
  2. Filter attenuation. The unipolar or bipolar switching components sit near 20 kHz or multiples of it, where the second-order filter attenuates by about (202)2=100=40dB
  3. Trade-offs. Raising the switching frequency or lowering the corner buys more attenuation; lowering the corner too far adds phase lag that the output voltage control must handle.

Answer m = 0.813, and the filter attenuates the switching component by about 100 (40 dB).

Check

A half-bridge inverter on a 400 V bus runs sinusoidal PWM at m = 0.5. What's the peak of its output's fundamental?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A full-bridge inverter on 400 V runs at m = 0.5. What's its fundamental's RMS?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A three-phase sinusoidal-PWM inverter on 650 V runs at m = 0.6. What's the line-to-line RMS voltage?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

With third-harmonic injection, what's the most line-to-line RMS voltage a three-phase inverter on 650 V can make without overmodulating?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

An inverter on 700 V switches at 5 kHz with 1 µs of dead time. About how large is the average voltage error?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

An inverter's carrier runs at 10 kHz and its output at 50 Hz. What's the frequency ratio mf around whose multiples the switching harmonics cluster?

Check

A full-bridge inverter on a 400 V bus makes 120 V RMS, switching at 20 kHz behind an LC filter with its corner at 2 kHz.

(a)

What modulation index?

(b)

About how much does the filter attenuate the switching frequency?

Check

An inverter on a bus of V volts runs sinusoidal PWM at index m.

Step 1

What fundamental peak does a half bridge give?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does adding a third harmonic to each phase's reference let a three-phase inverter make more voltage?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.