S11 · Lesson 10 · Transformer-isolated converters

Why chargers and off-line supplies need isolation, the flyback as a buck-boost with a coupled inductor, the forward converter and core reset, full-bridge converters, turns ratios to keep duty cycles reasonable, and the voltage stress on the switches

A laptop charger plugged into a 230 V outlet makes 20 V that you can touch safely. Somewhere inside, a transformer separates the mains side from the output, for safety and to bridge the huge voltage ratio efficiently. Switching converters make that transformer tiny, because it runs at hundreds of kilohertz instead of 50 or 60 Hz. Inserting a transformer into the buck-boost gives the flyback, into the buck gives the forward and bridge converters; their turns ratios let the duty cycle stay near the middle of its range even for large conversion ratios.

  • A flyback converter's output against duty cycle for a chosen turns ratio n=Ns/Np and input voltage: V=nD1−DVg.
  • Without the transformer, 48 V to 5 V would need D = 0.094 in a buck-boost. With 4:1 turns, D = 0.29.
  • The readout is the transistor's off-state voltage, Vg+V/n: the output reflected through the transformer adds to the input.

Predict

A flyback with a 4:1 transformer (n = 0.25) makes 5 V from 48 V. What voltage must its MOSFET block?

Name it

Why isolate

Safety standards require isolation between mains and anything a person can touch; isolation also allows multiple outputs, either polarity and large conversion ratios with sensible duty cycles.

Flyback

A buck-boost whose inductor has two windings: energy is stored in the magnetizing inductance while the switch is on and delivered through the secondary while it's off.

V=nD1−DVg,Vswitch=Vg+V/n

with n=Ns/Np. Simple and cheap, it dominates below about 100 W. Leakage inductance causes a voltage spike at turn-off that a clamp or snubber absorbs.

Forward

A buck with a transformer: power passes through the transformer while the switch is on, so V=nDVg. The core's magnetizing current must be reset each cycle; with a reset winding of the same turns as the primary, D≤0.5 and the switch blocks 2Vg.

Bridges

Half-bridge and full-bridge converters drive the transformer in both directions, using the core fully and suiting high power. For a full bridge applying ±Vg for a fraction D of the period, V=nDVg with D up to nearly 1, and each switch blocks only Vg.

Choosing n

Pick n so the nominal duty cycle is moderate (around 0.3 to 0.5), balancing switch voltage stress against current stress.

Worked example

Design the turns ratio for a 48 V to 5 V forward converter with a 1:1 reset winding.

Show the solution
  1. Smallest turns ratio. D can't exceed 0.5, so n≥50.5×48=0.208
  2. Take n = 0.25 (4:1). D=50.25×48=0.417 with margin for a low input.
  3. Switch voltage. During reset the switch blocks VQ=2×48=96V

Answer a 4:1 ratio (n = 0.25) gives D = 0.417, and the switch blocks 96 V during reset.

Worked example

An off-line flyback runs from 325 V (rectified 230 V AC) with 10:1 turns. What duty cycle gives 12 V, and what does the switch block?

Show the solution
  1. Duty cycle. 12=0.1D1−D325D1−D=0.369D=0.27
  2. Switch voltage. VQ=325+12×10=445V plus the leakage spike, so a 650 V or 800 V device is typical.

Answer D = 0.27, and the switch blocks 445 V plus the leakage spike.

Worked example

A flyback runs from a 400 V bus to 24 V with a maximum duty cycle of 0.45. Choose its turns ratio and find the switch's off-state voltage.

Show the solution
  1. Turns ratio. Solve V=nD1−DVg for n: n=24×0.550.45×400=0.0733 about 13.6:1 primary to secondary.
  2. Switch voltage. Off, the switch blocks VQ=Vg+V/n=400+24/0.0733=727V before any leakage spike, which is why off-line flybacks use 800 V or higher switches and a clamp.

Answer n = 0.0733 (about 13.6:1), and the switch blocks 727 V before any leakage spike.

Check

A flyback with Ns/Np = 0.25 runs from 325 V at D = 0.3. What's its output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A flyback with Ns/Np = 0.1 must make 12 V from 24 V. What duty cycle?

Check

For the same flyback, what voltage does the switch block (ignoring leakage spikes)?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A forward converter with Ns/Np = 0.25 runs from 100 V at D = 0.25. What's its output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A forward converter with a 1:1 reset winding must make 3.3 V from 48 V. What's the smallest turns ratio Ns/Np that works?

Check

A full bridge applies ±400 V to a transformer (Ns/Np = 0.1) for a fraction 0.3 of each period, rectified and filtered. What's the output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A flyback makes 5 V from 325 V at a maximum duty cycle of 0.45.

(a)

What turns ratio Ns/Np does it need?

(b)

What does its switch block?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A converter with turns ratio n runs from g volts at duty D.

Step 1

What does a flyback produce?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does a forward converter's duty cycle have a limit that a flyback's doesn't?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.