S1130 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S11 · Lesson 30 · Line-commutated rectifiers

Single-phase and three-phase diode bridges, phase control with thyristors and inverter operation, commutation overlap from source inductance, the 6k ± 1 harmonics of six-pulse bridges, and twelve-pulse cancellation

The rectifiers at the front of industrial drives, welders, electrochemical plants and HVDC terminals are still mostly diodes and thyristors switched by the AC line itself, not by a high-frequency clock. They're rugged and efficient, but their current comes in blocks that inject harmonics at fixed orders, and the line's own inductance stretches each commutation, costing output voltage. This lesson analyzes the six-pulse bridge that most of them are built from.

  • The DC output of a three-phase six-pulse thyristor bridge against its firing angle α: Vdc=1.35VLLcos⁡α−3πωLsId, with source inductance Ls and DC current Id.
  • At α = 0 it acts as a diode bridge. Beyond 90° the average voltage goes negative while the current keeps its direction: the converter feeds power back to the AC line as an inverter.
  • The commutation term subtracts a load-dependent drop, like an internal resistance that dissipates nothing.

Predict

A three-phase diode bridge runs from 480 V line to line with a large DC inductor. What's its DC output?

Name it

Single-phase bridge

With a large DC inductor, the output averages 22πVrms=0.90Vrms, and the line current is a square wave (distortion factor 0.90). With a capacitor instead, the output charges near the peak and the line current is narrow pulses (lesson 29).

Three-phase six-pulse bridge

Vdc=32πVLLcos⁡α=1.35VLLcos⁡α

with α the thyristors' firing delay (α = 0 for diodes). For α > 90° the average is negative: the bridge inverts, used in HVDC and regenerative drives. Each line current is a 120° block of height Id: Irms=2/3Id, fundamental RMS 6πId, and harmonics of order h=6k±1 (5, 7, 11, 13, ...) with amplitudes I1/h.

Commutation overlap

Source inductance Ls keeps the outgoing phase's current from dropping instantly; during the overlap two phases conduct and the output loses

ΔV=3πωLsId

a drop proportional to load that dissipates no power.

Twelve pulses

Two six-pulse bridges fed from Y–Y and Y–Δ transformers (30° apart) cancel the 5th and 7th harmonics at the line, leaving 11, 13, 23, 25, ...: the standard for large rectifiers and HVDC.

Worked example

A 480 V six-pulse thyristor bridge with 0.2 mH of source inductance carries 100 A. Find its output at α = 30°.

Show the solution
  1. Ideal output. V0=1.35×480×cos⁡30°=561V
  2. Overlap drop. ΔV=3π×377×0.2 mH×100=7.2V
  3. Output. V=561−7.2=554V
  4. Inverting. At α = 150° the same bridge would produce −561 V (less overlap), returning power to the line.

Answer the bridge puts out 554 V.

Worked example

What are the line current's RMS, fundamental and dominant harmonics for Id = 100 A?

Show the solution
  1. RMS line current. Irms=2/3×100A=81.6A
  2. Fundamental. I1=6π×100A=78.0A RMS, a distortion factor of 0.955.
  3. Dominant harmonics. Each is I1/h: I5=78.0/5=15.6AI7=11.1AI11=7.1A

Answer 81.6 A RMS with a 78.0 A fundamental, and harmonics of 15.6 A (5th), 11.1 A (7th) and 7.1 A (11th).

Worked example

Compare the line-current THD of an ideal six-pulse bridge with a twelve-pulse arrangement of two bridges fed 30° apart.

Show the solution
  1. Six pulses. The line current contains harmonics 6k ± 1 with amplitudes I1/h: 5, 7, 11, 13 and on. Their root-sum-square is THD=1/52+1/72+⋯=31.1%
  2. Twelve pulses. The twelve-pulse connection cancels the 5th, 7th, 17th, 19th and so on, leaving 12k ± 1: 11, 13, 23, 25: THD=1/112+1/132+⋯=15.2%
  3. The fundamental. It's the same in each case: I1=(6/π)Id=0.780Id
  4. Where it's used. Large drives and HVDC terminals use twelve or more pulses to meet harmonic limits with smaller filters.

Answer 31.1% THD for six pulses against 15.2% for twelve.

Check

A six-pulse bridge runs from 480 V line to line at firing angle 0°. What's its ideal DC output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A six-pulse bridge with 0.5 mH of source inductance carries 50 A at 60 Hz. How much output voltage does commutation overlap cost?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A single-phase diode bridge with a large DC inductor runs from 230 V RMS. What's its DC output?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A six-pulse bridge carries 200 A DC. What's the RMS of its line current's 5th harmonic?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A thyristor bridge on 480 V is fired at 120°. What's the magnitude of the DC voltage it applies while returning power to the line?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A six-pulse bridge carries 100 A DC (smooth). What's the RMS line current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

An ideal six-pulse bridge carries a smooth 200 A.

(a)

What is its line current's fundamental, RMS?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

And its 5th harmonic?

Check

A six-pulse thyristor bridge on V (line to line, 60 Hz) fires at angle a (radians) and carries I through source inductance L.

Step 1

What is its ideal DC output?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why does source inductance reduce a thyristor bridge's output without dissipating power?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.