S1124 of 55
0 XP
  1. Hook
  2. Play
  3. Predict
  4. Name it
  5. Check
  6. Explain

S11 · Lesson 24 · Magnetic circuits for power electronics

Reluctance and magnetic circuits, why inductor cores have air gaps, inductance from turns and reluctance, peak flux density and saturation, core loss and the Steinmetz equation, and copper loss with the skin effect

The inductors and transformers in a converter are usually its biggest, heaviest and lossiest parts, and unlike capacitors they're often designed for each application rather than bought off a shelf. The design rests on a few relations from magnetic circuits: flux follows the path of least reluctance, an air gap dominates the reluctance of a high-permeability core and so sets the inductance, and the core must not saturate at the peak current. This lesson builds those relations; the next two use them to design an inductor and a transformer.

  • A gapped ferrite core (cross-section Ac) wound with N turns: its inductance and peak flux density at a given current against the gap length (log axis), with the core's own reluctance neglected.
  • Widening the gap lowers the inductance in proportion but also lowers the flux density: gaps let a core carry DC current without saturating.
  • The dashed line is ferrite's usable flux density, about 0.3 T. Below it, the design is safe.

Predict

A ferrite core with a 100 mm² cross-section has a 0.5 mm gap and 20 turns. What's its inductance?

Name it

Magnetic circuits

Magnetomotive force ℱ=Ni drives flux Φ through reluctance ℛ=l/μA, like a voltage through a resistance: ℱ=Φℛ. Reluctances in series add. An inductor of N turns has

L=N2ℛ

Gaps

A ferrite core (μr in the thousands) with an air gap g: the gap's reluctance g/μ0Ac usually dominates, so L≈μ0N2Ac/g, stable against permeability changes, and the flux density is

B=ΦAc=LiNAc≈μ0Nig

Saturation

Above the saturation flux density Bsat (about 0.3 to 0.5 T for ferrite, 1 to 1.8 T for iron-based materials) permeability collapses and so does the inductance, letting the current spike. Design to the peak current: Bmax=LIpeak/NAc<Bsat.

Losses

  • Core loss from hysteresis and eddy currents, fitted by the Steinmetz equation Pv=kfαBacβ per unit volume, with α around 1.1 to 1.7 and β around 2.5 to 3 for ferrites. Bac is the peak AC flux density, half the peak-to-peak swing.
  • Copper loss Irms2R, raised at high frequency by the skin effect: current crowds within a depth δ=ρ/πfμ0 of a conductor's surface, 66 mm/√f for copper: 0.21 mm at 100 kHz. Litz wire or foil keeps conductors thinner than δ.

Worked example

The core above carries a peak of 3 A. Is it safe?

Show the solution
  1. Peak flux density. B=LiNAc=101μH×320×10−4=0.15T
  2. Compare with the limit. That's half of a typical ferrite's 0.3 T: safe. Doubling the current would bring it to the limit.
  3. Turns for 47 µH. With the same gap and core: N=Lgμ0Ac=13.7 so 14 turns.

Answer it's safe: 3 A gives 0.15 T, half of a typical ferrite's 0.3 T.

Worked example

How thick can a copper winding conductor be at 100 kHz and at 500 kHz before skin effect matters?

Show the solution
  1. Skin depth in copper. δ=0.066fm
  2. At 100 kHz. δ=0.066105m=0.21mm
  3. At 500 kHz. δ=0.0665×105m=0.093mm For comparison, it's 8.5 mm at 60 Hz.
  4. How thick a conductor can be. A round wire much thicker than about 2δ carries its high-frequency current only in its outer skin, so high-frequency windings use many fine insulated strands (Litz wire) or thin copper foil.

Answer the skin depth is 0.21 mm at 100 kHz and 0.093 mm at 500 kHz, and a round wire much thicker than about twice that carries its current only in its skin.

Worked example

A ferrite's loss density is 1.5f1.4B2.5 mW/cm³ (f in kHz, B in tesla). What does a 10 cm³ core lose at 100 kHz and 0.1 T, and what if the flux swing doubles?

Show the solution
  1. Loss density. p=1.5×1001.4×0.12.5=1.5×631×0.00316=2.99mW/cm3
  2. Core loss. P=2.99×10mW=30mW
  3. Doubling the flux swing. That multiplies the loss by 22.5 = 5.7: P=22.5×29.9mW=169mW
  4. Why it matters. Core loss rises much faster with flux than with frequency, which is why higher-frequency designs run at lower flux densities.

Answer the core loses 30 mW at 0.1 T, and 169 mW if the flux swing doubles.

Check

What's the reluctance of a 0.5 mm air gap across a 30 mm² core?

Write units the way you normally would: 1.5 A/Wb, 1500 mA/Wb and 0.0015 kA/Wb are the same answer.

Check

A gap-dominated core (200 mm², 0.2 mm gap) has 25 turns. What's its inductance?

Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.

Check

A gapped core has 10 turns carrying 1 A across a 1 mm gap. What's the flux density?

Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.

Check

What's the skin depth in copper at 100 kHz?

Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.

Check

How many turns give 47 µH on a 150 mm² core with a 0.3 mm gap?

Check

A ferrite's loss is Pv=2f1.5B2.6 mW/cm³ with f in kHz and B in tesla. What does a 5 cm³ core lose at 100 kHz and 0.1 T?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

Check

A ferrite's loss is 1f1.3B2.7 mW/cm³ (f in kHz, B in tesla); its core is 5 cm³.

(a)

What does it lose at 200 kHz and 0.05 T?

Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.

(b)

By what factor would doubling the flux swing raise the loss?

Check

A gap-dominated core of area A (m²) and gap g (m) carries N turns at current I.

Step 1

What is the gap's reluctance?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why do inductors for switching converters use gapped cores instead of solid high-permeability ones?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.