S11 · Lesson 31 · PWM rectifiers and power-factor correction

The ideal rectifier that looks like a resistor to the line, the boost power-factor corrector and its duty cycle over the line period, the twice-line-frequency energy that the bulk capacitor must buffer, and hold-up time

Since 2001, equipment sold in Europe above 75 W has had to keep its line-current harmonics within IEC 61000-3-2 limits, which a plain diode bridge with a capacitor can't meet. The fix is a boost converter right after the bridge, controlled so the current it draws follows the rectified line voltage: to the outlet the whole power supply looks like a resistor, with a power factor above 0.99. The price is a capacitor that must ride through the moments when the line voltage passes zero and no power comes in.

  • One line cycle of a boost PFC stage from 230 V to a 400 V bus: the rectified line voltage (dashed, scaled to the bus) and the duty cycle the boost must use to draw a sinusoidal current, d(t)=1−|vg(t)|/V.
  • Near the line's peak the boost needs a small duty cycle; near zero crossings it approaches 1.
  • The line current is proportional to |vg|: the input looks like a resistor Re=Vrms2/P.

Predict

A 500 W boost PFC runs from 230 V RMS. What resistance does it emulate, and what's the peak line current?

Name it

The ideal rectifier

A rectifier whose input behaves as a resistance Re draws a current proportional to the line voltage: unity power factor and no harmonics. It delivers P=Vrms2/Re; the controller adjusts Re to regulate the output.

The boost PFC

A diode bridge followed by a boost converter. To keep its inductor current following |vg(t)|/Re while holding the output at V, the duty cycle varies over each half cycle:

d(t)=1−|vg(t)|V

which requires V>2Vrms (typically 380 to 400 V for 230 V lines). Control usually nests an inner current loop (following a scaled copy of |vg|) inside a slow outer voltage loop.

Energy buffering

Input power pulses at twice line frequency, from 0 to 2P, while the output draws a steady P. The bulk capacitor absorbs the difference, so its voltage ripples at 2fline with peak-to-peak amplitude

ΔVpp≈P2πflineCV

The outer voltage loop must be slower than this ripple (crossover around 10 to 20 Hz) or it would distort the input current.

Hold-up

If the line drops out, the capacitor must keep the downstream converter running for a specified hold-up time th (often 10 to 20 ms) while its voltage falls from V to a minimum Vmin: C≥2Pth/(V2−Vmin2).

Worked example

Size the bulk capacitor of the 500 W, 400 V PFC for both ripple and hold-up.

Show the solution
  1. Ripple with 330 µF. The 100 Hz ripple is Δv=5002π×50×330μF×400=12.1V peak to peak, 3% of the bus.
  2. Hold-up. From 400 V down to 300 V it lasts t=330μF×(4002−3002)2×500=23.1ms more than a 20 ms (one cycle) requirement.
  3. What sets the size. Hold-up usually sets the capacitor's size.

Answer 330 µF gives 12.1 V of ripple (3% of the bus) and 23.1 ms of hold-up, enough for a 20 ms requirement.

Worked example

What duty cycle does the boost need at the line's peak, and what happens near the zero crossings?

Show the solution
  1. At the peak. d=1−325.3400=0.187
  2. Near the zero crossings. |vg| approaches zero and d approaches 1.
  3. The input current there. There's almost no voltage to draw current from, so the input current goes to zero with the voltage, as a resistor's would.

Answer d = 0.187 at the peak, rising toward 1 near the zero crossings, where the input current goes to zero with the voltage.

Worked example

A 500 W boost PFC on 230 V runs a 400 V bus at 100 kHz with a 500 µH inductor. What is its inductor ripple at the line's peak, relative to the line current there?

Show the solution
  1. Duty cycle at the peak. There vg = 325 V, so d=1−vg/400=0.187
  2. Inductor ripple. ΔI=vgdLfs=325×0.187500μH×100 kHz=1.22A
  3. Against the line current. The peak line current is Ipk=2×500/230=3.07A so the ripple is 40% of it.
  4. At light load. The same ripple is a larger fraction, and the converter drifts into discontinuous conduction near the zero crossings.

Answer the ripple is 1.22 A, 40% of the 3.07 A peak line current.

Check

A PFC rectifier delivers 100 W from 230 V RMS. What resistance does it emulate?

Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.

Check

What's the peak line current of an ideal 150 W PFC on 120 V RMS?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A boost PFC regulates 385 V from 120 V RMS. What duty cycle does it use when the line is at 80° of its cycle?

Check

A 750 W PFC with a 400 V bus on a 50 Hz line has 1500 µF of bulk capacitance. What's its twice-line ripple, peak to peak?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A 600 W supply must hold up for 10 ms while its bus falls from 400 V to 300 V. How much capacitance?

Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.

Check

What's the lowest bus voltage a boost PFC on a 230 V RMS line can regulate?

Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.

Check

A 300 W boost PFC on 120 V RMS runs a 400 V bus with a 600 µH inductor at 65 kHz.

(a)

What is the peak line current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What inductor ripple does it have at the line's peak?

Check

A boost PFC with bus voltage B runs on a line of V RMS, at line angle t.

Step 1

What is the rectified line voltage?

Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.

Explain why

Why must a PFC's output voltage loop be much slower than the line frequency?

Practice

Keep practicing

10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.