S11 · Lesson 31 · PWM rectifiers and power-factor correction
The ideal rectifier that looks like a resistor to the line, the boost power-factor corrector and its duty cycle over the line period, the twice-line-frequency energy that the bulk capacitor must buffer, and hold-up time
Since 2001, equipment sold in Europe above 75 W has had to keep its line-current harmonics within IEC 61000-3-2 limits, which a plain diode bridge with a capacitor can't meet. The fix is a boost converter right after the bridge, controlled so the current it draws follows the rectified line voltage: to the outlet the whole power supply looks like a resistor, with a power factor above 0.99. The price is a capacitor that must ride through the moments when the line voltage passes zero and no power comes in.
- One line cycle of a boost PFC stage from 230 V to a 400 V bus: the rectified line voltage (dashed, scaled to the bus) and the duty cycle the boost must use to draw a sinusoidal current, .
- Near the line's peak the boost needs a small duty cycle; near zero crossings it approaches 1.
- The line current is proportional to : the input looks like a resistor .
Predict
A 500 W boost PFC runs from 230 V RMS. What resistance does it emulate, and what's the peak line current?
An ideal rectifier draws , so = 230²/500 = 105.8 Ω, and the current peaks at = 3.07 A. Its RMS is 500/230 = 2.17 A, exactly what a resistor would draw.
Name it
The ideal rectifier
A rectifier whose input behaves as a resistance draws a current proportional to the line voltage: unity power factor and no harmonics. It delivers ; the controller adjusts to regulate the output.
The boost PFC
A diode bridge followed by a boost converter. To keep its inductor current following while holding the output at V, the duty cycle varies over each half cycle:
which requires (typically 380 to 400 V for 230 V lines). Control usually nests an inner current loop (following a scaled copy of ) inside a slow outer voltage loop.
Energy buffering
Input power pulses at twice line frequency, from 0 to 2P, while the output draws a steady P. The bulk capacitor absorbs the difference, so its voltage ripples at with peak-to-peak amplitude
The outer voltage loop must be slower than this ripple (crossover around 10 to 20 Hz) or it would distort the input current.
Hold-up
If the line drops out, the capacitor must keep the downstream converter running for a specified hold-up time (often 10 to 20 ms) while its voltage falls from V to a minimum : .
Worked example
Size the bulk capacitor of the 500 W, 400 V PFC for both ripple and hold-up.
Show the solution
- Ripple with 330 µF. The 100 Hz ripple is peak to peak, 3% of the bus.
- Hold-up. From 400 V down to 300 V it lasts more than a 20 ms (one cycle) requirement.
- What sets the size. Hold-up usually sets the capacitor's size.
Answer 330 µF gives 12.1 V of ripple (3% of the bus) and 23.1 ms of hold-up, enough for a 20 ms requirement.
Worked example
What duty cycle does the boost need at the line's peak, and what happens near the zero crossings?
Show the solution
- At the peak.
- Near the zero crossings. approaches zero and d approaches 1.
- The input current there. There's almost no voltage to draw current from, so the input current goes to zero with the voltage, as a resistor's would.
Answer d = 0.187 at the peak, rising toward 1 near the zero crossings, where the input current goes to zero with the voltage.
Worked example
A 500 W boost PFC on 230 V runs a 400 V bus at 100 kHz with a 500 µH inductor. What is its inductor ripple at the line's peak, relative to the line current there?
Show the solution
- Duty cycle at the peak. There = 325 V, so
- Inductor ripple.
- Against the line current. The peak line current is so the ripple is 40% of it.
- At light load. The same ripple is a larger fraction, and the converter drifts into discontinuous conduction near the zero crossings.
Answer the ripple is 1.22 A, 40% of the 3.07 A peak line current.
Check
A PFC rectifier delivers 100 W from 230 V RMS. What resistance does it emulate?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What's the peak line current of an ideal 150 W PFC on 120 V RMS?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A boost PFC regulates 385 V from 120 V RMS. What duty cycle does it use when the line is at 80° of its cycle?
Check
A 750 W PFC with a 400 V bus on a 50 Hz line has 1500 µF of bulk capacitance. What's its twice-line ripple, peak to peak?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 600 W supply must hold up for 10 ms while its bus falls from 400 V to 300 V. How much capacitance?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
What's the lowest bus voltage a boost PFC on a 230 V RMS line can regulate?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 300 W boost PFC on 120 V RMS runs a 400 V bus with a 600 µH inductor at 65 kHz.
(a)
What is the peak line current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What inductor ripple does it have at the line's peak?
Check
A boost PFC with bus voltage B runs on a line of V RMS, at line angle t.
Step 1
What is the rectified line voltage?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What duty cycle does it need?
Explain why
Why must a PFC's output voltage loop be much slower than the line frequency?
An ideal rectifier draws power that pulses at twice the line frequency, while the load downstream draws steady power, so the bus capacitor's voltage necessarily ripples at twice line frequency. If the voltage loop responded to that ripple, it would vary the emulated resistance within each line cycle, raising the current near some parts of the sine and lowering it near others, and the input current would no longer be proportional to the voltage. Keeping the loop's crossover far below twice the line frequency, typically around 10 to 20 Hz, makes the controller ignore the ripple and hold the emulated resistance nearly constant over each cycle, preserving a sinusoidal input current at the cost of a slow response to load changes.
Practice
Keep practicing
10 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.