S11 Power electronics · Practice
Every topic, mixed
Problems dealt one at a time, with new numbers every time. The kinds you miss come back more often, and you can keep going as long as you like.
Topics: all 51
Check
What's the best efficiency a linear regulator can have dropping 24 V to 1.8 V?
Check
A linear regulator drops 12 V to 3.3 V at 5 A. How much does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A switch connects 5 V to a node for a fraction 0.45 of each period and grounds it the rest. What's the node's average voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A converter delivers 20 W at 0.85 efficiency. How much does it lose?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A 12 V switch waveform has duty cycle 0.2. What's the amplitude of its first harmonic?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 50% duty 12 V switch waveform at 500 kHz drives an LC filter with its corner at 2 kHz. Estimate the fundamental ripple left at the output.
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Two converters in cascade run at 0.94 and 0.85 efficiency, delivering 200 W.
(a)
What is the overall efficiency?
(b)
How much power is lost?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Linear regulator efficiency, 15 V to 1.2 V?
Check
Loss at 0.8 efficiency delivering 2 W?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
First harmonic of a 9 V, D = 0.3 pulse train?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck converter runs from 12 V at D = 0.25. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost converter runs from 12 V at D = 0.3. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost must raise 12 V to 1.5 times that. What duty cycle?
Check
A boost at D = 0.4 delivers 2 A. What's its inductor's average current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck-boost runs from 12 V at D = 0.3. What's the magnitude of its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost raises 5 V to 15 V. What's the voltage across its inductor while the switch is off?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck converts 48 V to 5 V at 20 A.
(a)
What is its duty cycle?
(b)
What average current does its transistor carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
And its diode?
Check
Boost output: 9 V at D = 0.2?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Buck-boost output magnitude: 5 V at D = 0.35?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Boost inductor current: 1 A at D = 0.25?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck from 12 V to 3.3 V uses 22 µH at 500 kHz. What's its peak-to-peak inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck's inductor ripple is 0.5 A peak to peak, at 200 kHz with 47 µF of output capacitance (no ESR). What's the output ripple?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A boost delivering 2 A at D = 0.4, 300 kHz has 47 µF at its output. What's the output ripple?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 12 V to 3.3 V buck at 10 A and 300 kHz should have ripple of 0.4 of its load current. What inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
An inductor carries 3 A average with 0.3 A peak-to-peak ripple. What peak current must it carry without saturating?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A capacitor with 2 mΩ of ESR carries 1 A of peak-to-peak ripple current. How much ripple voltage does the ESR add?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A boost raises 12 V to 2 times that at 3 A out, switching at 100 kHz with ripple 0.4 of its inductor current.
(a)
What is the average inductor current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What inductance is needed?
(c)
What peak current must it carry?
Check
Buck ripple: 15 → 2.5 V, 33 µH, 400 kHz?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Boost output ripple: 1 A, D = 0.3, 500 kHz, 100 µF?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Buck output ripple: 0.4 A p-p, 250 kHz, 22 µF?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A SEPIC makes 3.3 V from 5 V. What duty cycle does it need?
Check
A Ćuk converter makes −3 V from 12 V. What voltage does its coupling capacitor charge to?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck-boost runs from 12 V at D = 0.3. What off-state voltage must its transistor block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost delivers 1 A at D = 0.4 with 0.6 A of peak-to-peak inductor ripple. What peak current does its transistor carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A SEPIC runs from 9 V at D = 0.35. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck-boost at D = 0.3 delivers 2 A. What's the average current through its transistor?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A SEPIC makes 5 V at 2 A from 5 V.
(a)
What duty cycle?
(b)
What voltage must its transistor block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
What average current does its transistor carry?
Check
SEPIC duty: 2.7 → 1.8 V?
Check
Buck-boost switch stress: 9 V at D = 0.25?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Average transistor current: buck-boost, 1 A, D = 0.35?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A 2:1 series-parallel converter has a 10 µF flying capacitor switched at 100 kHz. What is its slow-switching-limit output resistance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A 2:1 switched-capacitor converter runs from 12 V with 0.1 Ω output resistance and supplies 20 A.
(a)
What is the output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is its efficiency, ignoring switching losses?
Check
At what switching frequency do the slow and fast limits of a 2:1 converter (flying capacitor 10 µF, switches 5 mΩ) give equal output resistance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A converter's slow-switching limit is 50 mΩ and its fast-switching limit 10 mΩ. What output resistance does the usual estimate give?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A battery at 3.7 V feeds a 2:1 converter that must deliver at least 1.7 V at 2 A. What is the largest output resistance allowed?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
Choose a switching frequency. A 48 V-to-24 V 2:1 converter with flying capacitor C = 4.7 µF and switches of Ron = 5 mΩ delivers P = 500 W. Switching losses are 2 mW per kHz. Write loss(f_khz): conduction loss with and , plus switching loss. Search integer frequencies from 10 to 5000 kHz for the minimum, and set f_best and eff_best (efficiency, as a fraction, ignoring that the output sags).
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
What is the SSL resistance of a 2:1 converter with 3.3 µF at 200 kHz?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
What efficiency does a 2:1 converter from 36 V reach at 15 A with 0.03 Ω output resistance?
Check
Converting 12 V to 3.3 V at 4 A.
(a)
Linear regulator's dissipation?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
A switcher's loss at 0.95 efficiency?
(c)
Buck duty cycle?
Check
A 12 V switch waveform at duty 0.3, 400 kHz, filtered by an LC with its corner at 8 kHz.
(a)
DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
First harmonic at the switch node?
(c)
Left at the output?
Check
A converter runs from 12 V at D = 0.35, delivering 3 A.
(a)
Output if it's a boost?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Boost inductor current?
(c)
Output magnitude if it's a buck-boost?
Check
A boost must raise 3.3 V by a factor of 1.5.
(a)
Duty cycle?
(b)
Inductor voltage during the off-time?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck from 12 V to 1.8 V at 2 A, 15 µH, 800 kHz, 22 µF.
(a)
Inductor ripple, peak to peak?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Peak inductor current?
(c)
Output ripple (no ESR)?
Check
A boost from 5 V to 24 V at 2 A, 250 kHz, 22 µH, 10 µF.
(a)
Inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Output ripple?
Check
A 12 V to 1.2 V buck at 10 A and 200 kHz, ripple fraction 0.4; its output capacitor has 3 mΩ of ESR.
(a)
Inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
ESR ripple?
Check
A SEPIC from 4.2 V to 3.3 V at 2 A.
(a)
Duty cycle?
(b)
Transistor voltage stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Average transistor current?
Check
A Ćuk converter makes −5 V from 9 V at 3 A.
(a)
Duty cycle?
(b)
Coupling capacitor voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Average input current?
Check
A buck-boost from 5 V at D = 0.25, 4 A out.
(a)
Transistor voltage stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Average transistor current?
Check
A boost at 2 A out, D = 0.5, inductor ripple 1.2 A, 100 µF, 150 kHz.
(a)
Transistor peak current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Output ripple?
Check
A 3 W converter at 0.85 efficiency, with a thermal resistance of 85 °C/W from its hottest part to ambient (all the loss in that part).
(a)
Loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Temperature rise?
Check
A boost makes 15 V from 9 V at 2 A.
(a)
What is the inductor's average current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What RMS current flows in the output capacitor (ignoring the inductor's ripple)?
Check
A buck from 24 V to 3.3 V at 10 A and 500 kHz has 10 µF of input capacitance; the source supplies only DC.
(a)
What RMS current does the input capacitor carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What peak-to-peak ripple does it have?
Check
An inverting buck-boost makes −5 V from 12 V at 4 A.
(a)
What duty cycle?
(b)
What must the switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
What is the inductor's average current?
Check
A 2:1 switched-capacitor converter has a 4.7 µF flying capacitor at 200 kHz and 15 mΩ switches, from 48 V at 20 A.
(a)
What output resistance does the combined estimate give?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
(b)
What output voltage results?
Check
A boost with 0.02 Ω of inductor resistance feeds 10 Ω at D = 0.85. What's its efficiency (other losses ignored)?
Check
A boost from 5 V at D = 0.8 has 0.1 Ω of inductor resistance and a 5 Ω load. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost has inductor resistance 0.01 Ω and a 20 Ω load. What's the largest output ratio it can reach?
Check
A buck makes 1 V from 12 V through a diode with 0.7 V of forward drop. What duty cycle?
Check
For the same buck, what's the efficiency, counting only the diode?
Check
A synchronous rectifier MOSFET with 2 mΩ on-resistance carries 15 A during the off-time of a buck at D = 0.3. What does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A buck's rectifier carries 15 A while the transistor is off (D = 0.1). Compare a diode with a 0.7 V drop and a synchronous MOSFET of 10 mΩ.
(a)
What does the diode lose?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What does the MOSFET lose?
Check
Boost efficiency: = 0.02, R = 4, D = 0.8?
Check
Maximum boost ratio: R = 8, = 0.02?
Check
Buck duty with diode: 9 → 1.5 V, = 0.8?
Check
A buck's high-side MOSFET (3 mΩ) carries 15 A at D = 0.8. Ignoring ripple, what's its conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A switch turns 2 A on and off against 48 V, with rise and fall times of 40 ns each, at 500 kHz. Estimate its transition loss.
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A MOSFET with 500 pF of output capacitance turns on from 48 V at 1000 kHz. What loss does discharging that capacitance cause?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A diode with 100 nC of reverse-recovery charge is turned off against 48 V at 200 kHz. Estimate the reverse-recovery loss.
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A converter delivers 200 W and its losses total 1 W. What's its efficiency?
Check
At what switching frequency does a MOSFET's transition loss (100 V, 5 A, 10 ns each way) equal its conduction loss (5 mΩ at D = 0.5)?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A switch commutates 5 A against 48 V with 50 ns rise and fall times at 500 kHz.
(a)
What is its transition loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Conduction loss: 8 A, 4 mΩ, D = 0.7?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Transition loss: 12 V, 3 A, 50 ns, 1000 kHz?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
loss: 50 pF, 24 V, 2000 kHz?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A converter has L = 22 µH, = 100 kHz and a 50 Ω load. What's K?
Check
A buck with a diode rectifier has L = 10 µH and runs at 200 kHz with D = 0.7. Above what load resistance does it enter DCM?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A buck runs in DCM at D = 0.4 with K = 0.05. What's its conversion ratio?
Check
A boost runs in DCM at D = 0.5 with K = 0.01. What's its conversion ratio?
Check
A buck-boost runs in DCM at D = 0.35 with K = 0.04. What's the magnitude of its conversion ratio?
Check
A boost has L = 10 µH at 100 kHz and D = 0.7. Above what load resistance does it enter DCM?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A buck-boost with L = 10 µH switches at 100 kHz into 500 Ω at D = 0.4.
(a)
What is K?
(b)
What is the magnitude of its conversion ratio?
Check
K for L = 6.8 µH, 150 kHz, R = 20 Ω?
Check
Buck DCM ratio: D = 0.15, K = 0.02?
Check
Buck critical load: L = 3.3 µH, 250 kHz, D = 0.6?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A flyback with = 0.25 runs from 325 V at D = 0.3. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A flyback with = 0.1 must make 12 V from 24 V. What duty cycle?
Check
For the same flyback, what voltage does the switch block (ignoring leakage spikes)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A forward converter with = 0.25 runs from 100 V at D = 0.25. What's its output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A forward converter with a 1:1 reset winding must make 3.3 V from 48 V. What's the smallest turns ratio that works?
Check
A full bridge applies ±400 V to a transformer ( = 0.1) for a fraction 0.3 of each period, rectified and filtered. What's the output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A flyback makes 5 V from 325 V at a maximum duty cycle of 0.45.
(a)
What turns ratio does it need?
(b)
What does its switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Flyback output: n = 0.05, D = 0.25, 380 V?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Flyback switch stress: n = 0.08, 36 V in, 24 V out?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Minimum forward turns ratio: 36 V to 5 V?
Check
A boost from 9 V at D = 0.75, inductor resistance 0.08 Ω, load 8 Ω.
(a)
Efficiency?
(b)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Maximum achievable ratio?
Check
A 12 V to 1 V buck at 10 A with a 0.6 V diode; or with a synchronous MOSFET of 4 mΩ instead.
(a)
Duty cycle with the diode?
(b)
Diode's loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(c)
Synchronous MOSFET's loss (D = V/V_g)?
Check
A switch at 48 V, 5 A, 30 ns transitions, 400 kHz, = 200 pF, diode = 30 nC.
(a)
Transition loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Output-capacitance loss?
(c)
Reverse-recovery loss?
Check
A MOSFET (3 mΩ) carrying 6 A at D = 0.6, switching 60 V with 8 ns transitions; the converter delivers 80 W.
(a)
Conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Frequency where transition loss equals it?
(c)
Efficiency at that frequency, counting only these two losses?
Check
A buck with L = 4.7 µH at 200 kHz, D = 0.5, load 40 Ω.
(a)
K?
(b)
Critical load resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A converter at D = 0.2 with K = 0.04, in DCM.
(a)
Buck ratio?
(b)
Buck-boost ratio magnitude?
Check
A boost at D = 0.3.
(a)
DCM ratio at K = 0.01?
(b)
Critical load with L = 33 µH at 300 kHz?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A flyback with = 0.1 making 12 V from 36 V.
(a)
Duty cycle?
(b)
Switch stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A forward converter with a 1:1 reset winding makes 3.3 V from 48 V, with its turns ratio chosen 1.5 times the minimum.
(a)
Turns ratio ?
(b)
Duty cycle?
(c)
Switch stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A full bridge from 400 V with = 0.05, D = 0.4, delivering 30 A.
(a)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Average input current (lossless)?
(c)
Each switch's blocking voltage?
Check
A 20 W converter with conduction loss 0.5 W, switching loss 3 W, diode loss 1.5 W and magnetics loss 0.2 W.
(a)
Total loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Efficiency?
(c)
Efficiency gained by eliminating switching loss (soft switching)?
Check
A boost from 5 V at D = 0.4 has 60 mΩ of inductor resistance and a diode dropping 0.7 V, and feeds 10 Ω.
(a)
What output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What efficiency?
Check
A buck-boost from 12 V at D = 0.2 uses 5 µH at 200 kHz and feeds 100 Ω.
(a)
What is K?
(b)
It's in DCM (). What output magnitude does it make?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 40 mΩ MOSFET and an IGBT with a 1.2 V saturation voltage each conduct a DC current.
(a)
Above what current does the MOSFET dissipate more?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
At 80 A, what is the MOSFET's loss as a fraction of the IGBT's?
Check
A boost with 47 µH at 50 kHz runs at D = 0.7.
(a)
What is its ?
(b)
Above what load resistance does it enter DCM?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
3 interleaved buck phases run at D = 0.08.
(a)
What fraction of one phase's ripple is the total output ripple?
(b)
How many times the switching frequency is the total ripple?
Check
A 4-phase regulator makes 1.2 V from 12 V with 0.15 µH per phase at 600 kHz.
(a)
What is each phase's ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the total output ripple?
Check
Two buck phases interleave at D = 0.2. One phase alone would ripple 4 A at 500 kHz; the output has 470 µF.
(a)
What is the total ripple current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What output voltage ripple does the capacitor allow?
Check
Two phases with inductor resistances 0.8 and 1.5 mΩ share 60 A at a common duty cycle.
(a)
What does the first carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
3 phases interleave.
(a)
At what smallest nonzero duty cycle does the output ripple cancel completely?
(b)
How far apart are the phases' switching instants, in degrees of a period?
Check
A 100 W, 1 V output is split among 2 phase(s), each with 5 mΩ of conduction resistance.
(a)
What is the total conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Total ripple of two phases at D = 0.15, each rippling 5 A?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Current in the 1 mΩ phase of two sharing 40 A (other 2.5 mΩ)?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Smallest duty cycle for perfect cancellation with 4 phases?
Check
A DAB has 400 V on side 1 and 300 V (referred) on side 2, with 60 µH at 200 kHz.
(a)
What is its maximum power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What does it transfer at a 30° phase shift?
Check
A DAB with 400 V on each side (referred), 20 µH at 100 kHz, must deliver 3 kW.
(a)
What phase shift does it need?
Check
A synchronous leg links a 48 V battery to a 380 V bus.
(a)
What duty does the upper switch run at while charging the battery?
(b)
What duty does the lower switch run at while discharging?
Check
A 50 Ah battery is charged from empty at 0.3C until it reaches 80%.
(a)
What is the charging current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
How long does that phase take?
Check
A DAB with 400 V and 400 V (referred) at 100 kHz must be able to deliver 20 kW at a phase shift of 90°.
(a)
What series inductance does that allow at most?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A DAB's transformer has ratio 8.33:1 and its low side sits at 24 V.
(a)
What does the low side look like referred to the high side?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Maximum DAB power: 400 V both sides, 45 µH, 100 kHz?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
Boost duty discharging a 24 V battery into 400 V?
Check
Time to 80% at 0.5C?
Check
A 3000 mAh cell is charged at 0.5C. How long would the charge take if the full current flowed throughout (no CV tail)?
Check
A cell with and internal resistance 0.05 Ω is charged at 1 A to 4.2 V. At what percentage charge does the CV phase begin?
Check
During CV at 4.2 V, a cell with and 0.05 Ω internal resistance is at = 0.95. What current flows?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A bleed resistor of 33 Ω balances a cell at 4.1 V that is 200 mAh fuller than its neighbors.
(a)
What current does it bleed?
Write units the way you normally would: 1.5 mA, 1500 µA and 0.0015 A are the same answer.
(b)
How long does balancing take?
Check
A coulomb counter's current sensor has an offset of 2 mA. Uncorrected for 3 days, what error does it accumulate, as a percentage of a 5 Ah cell's capacity?
Check
A pack is built 7S2P from 5 Ah cells charged to 4.2 V each. What is its full-charge voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Simulate a CC-CV charge. A cell of capacity 3 Ah has and internal resistance R = 0.05 Ω, starting empty. Charge at I = 1 A until reaches 4.2 V, then hold 4.2 V until the current falls below 0.15 A (C/20). Step 1 second at a time (update the charge after computing each step's current). Set t_total (hours), t_cc (hours in CC), and q_end, the final state of charge.
Python 3.14 with numpy and matplotlib, running in your browser. Tab indents; press Esc and then Tab to move on.
Check
How long would a charge at 0.5C take with full current throughout?
Check
What is the full-charge voltage of a 4-cell series lithium-ion pack?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Two interleaved buck phases make 1.8 V at D = 0.1, each with 2.2 µH at 600 kHz, into 100 µF.
(a)
What is each phase's inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the total output current's ripple?
(c)
What output voltage ripple results, ignoring ESR?
Check
4 interleaved buck phases make 5 V at D = 0.15, each with 1 µH at 400 kHz.
(a)
What is the total output current's ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
At what frequency is that ripple?
Check
Two phases with a common duty cycle share 40 A; their current paths have 2 and 5 mΩ.
(a)
How much current does the 2 mΩ phase carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What conduction loss do the two paths dissipate together?
Check
A bidirectional leg links a 12 V battery to an 80 V bus through 22 µH at 200 kHz.
(a)
What duty cycle does the high-side switch run at while charging the battery?
(b)
What is the inductor's ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
When the battery supports the bus, what duty cycle does the low-side switch run at?
Check
A pack of 7 lithium-ion cells in series, 2.5 Ah, is charged at 1C to 4.2 V per cell by a charger of efficiency 0.95.
(a)
What is the constant-current phase's current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Starting empty, about how long does the constant-current phase take to reach 80%?
(c)
What input power does the charger draw at the end of that phase?
Check
A dual active bridge has 380 V on side 1 and 360 V on side 2 (referred to side 1), 60 µH of series inductance, switching at 200 kHz, with side 2 lagging by 15°.
(a)
How much power flows?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What is the most it can transfer?
Check
A dual active bridge with equal referred voltages of 400 V, 50 µH and 50 kHz must deliver 0.8 of its maximum power.
(a)
What is its maximum power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What phase shift does it need?
Check
A buck from 12 V delivers 20 A; each switching edge lasts 20 ns and the switches have 500 pF of output capacitance. Compare one phase at 500 kHz with 2 interleaved phases at 500/2 kHz each, which keeps the same output ripple frequency.
(a)
What overlap loss does the single phase have?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What total overlap loss do the interleaved phases have?
(c)
What total output-capacitance loss do the interleaved phases have?
Check
2 interleaved buck phases with diodes make 1.2 V at D = 0.3, each with 2.2 µH at 300 kHz.
(a)
Below what load current do the phases enter the discontinuous mode?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck draws 30 A of output current at D = 0.15.
(a)
What RMS ripple current flows in its input capacitor with one phase?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And with two interleaved phases?
Check
A synchronous buck leg makes 5 V at D = 0.25 with 4.7 µH at 500 kHz, and the load draws 0.5 A.
(a)
What is the inductor's ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the inductor current's minimum (negative means it flows back toward the input)?
Check
A battery holds up a bus at 2 kW for 5 minutes through a converter of efficiency 0.96; the battery sits at 400 V.
(a)
How much energy must the battery deliver?
Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.
(b)
What current does it supply?
Check
A processor rail draws 150 A at 1.2 V from 12 V, with phases rated 25 A each at 600 kHz, designed for an inductor ripple of 0.3 of each phase's share.
(a)
How many phases does it need?
(b)
What inductance does each phase use?
Write units the way you normally would: 1.5 nH, 1500 pH and 0.0015 µH are the same answer.
Check
A dual active bridge links a 400 V bus to a battery of nominal 48 V, through 40 µH at 100 kHz; the turns ratio makes the nominal battery voltage, referred to the bus side, equal 400 V.
(a)
What turns ratio ?
(b)
What is its maximum power when the battery has fallen to 0.85 of nominal?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A multiphase converter carries 60 A. Each phase has 2 mΩ of conduction path and costs 1.2 W of fixed loss (driver, controller share, core).
(a)
What are the total losses with 6 phases?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What number of phases (before rounding) minimizes them?
Check
A cell with and 0.05 Ω charges at 0.5 A to 4.2 V; its balancing resistor is 68 Ω.
(a)
At what charge percentage does CV begin?
(b)
What current does the balancing resistor bleed at 4.2 V?
Write units the way you normally would: 1.5 mA, 1500 µA and 0.0015 A are the same answer.
Check
A buck has L = 10 µH and C = 10 µF. Where's the resonance of its control-to-output transfer function?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A buck with L = 15 µH and C = 10 µF feeds 10 Ω. What's the Q of its resonance?
Check
A boost at D = 0.5 has L = 22 µH and C = 47 µF. Where's its resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A boost at D = 0.5 with L = 22 µH feeds 50 Ω. Where's its right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
What's the DC gain of a boost's control-to-output transfer function, from 12 V at D = 0.4, in volts per unit duty cycle?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
How high above its DC gain does a buck's control-to-output transfer function peak at resonance (L = 4.7 µH, C = 100 µF, R = 5 Ω)?
Check
A buck has L = 10 µH and C = 22 µF and feeds 50 Ω.
(a)
Where is its resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How high is the resonant peak, given by Q = R/Z₀?
Check
Buck resonance: L = 2.2 µH, C = 22 µF?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Boost RHP zero: D = 0.4, L = 15 µH, R = 40 Ω?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Boost DC duty gain: 3.3 V, D = 0.35?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An output capacitor of 10 µF has 20 mΩ of ESR. Where's its ESR zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A buck from 12 V senses its 5 V output with a divider to a 0.6 V reference, through a PWM with a 2 V ramp. What's its uncompensated DC loop gain?
Check
A buck makes 1.8 V from 12 V open loop. If the input rises by 2 V, how much does the output rise?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A 3.3 V output is regulated against a 0.6 V reference. What's the divider ratio H?
Check
A converter's open-loop output impedance at some low frequency is 20 mΩ, and its loop gain there is 10. What's its closed-loop output impedance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A buck's output impedance peaks near its LC resonance at about . With L = 4.7 µH, C = 22 µF and a 5 Ω load, how high?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
An output capacitor of 470 µF has 10 mΩ of ESR; the loop crosses over at 30 kHz.
(a)
Where is its ESR zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How much phase does it add at crossover?
Check
ESR zero: 47 µF, 5 mΩ?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Uncompensated loop gain: 9 V in, 12 V out, 0.8 V reference, 1.5 V ramp?
Check
Closed-loop output impedance: 10 mΩ, T = 20?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
Check
A type III compensator has an integrator, two zeros at 8 kHz and two poles at 150 kHz. What phase does it contribute at 60 kHz?
Check
A second-order plant with Q = 1. What's its phase at 4 times ?
Check
A plant's magnitude is 3 (flat) near the crossover, and the compensator is a pure integrator . What puts the crossover at 20 kHz?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
Check
At crossover the plant's phase is −160° and the compensator adds 20°. What's the phase margin?
Check
A boost at D = 0.6 with L = 22 µH feeds 40 Ω. By the one-fifth rule, how high may its crossover be set?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A type II compensator's zero is at 2 kHz and its pole at 50 kHz. What's the most phase boost its zero–pole pair gives?
Check
A type II compensator has its zero at 5 kHz and its pole at 50 kHz.
(a)
How much phase does the zero–pole pair add at 40 kHz?
(b)
At what frequency is that boost largest?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Type III phase at 80 kHz: zeros 4 kHz, poles 120 kHz?
Check
Phase margin: plant −170°, compensator 30°?
Check
Boost crossover limit (one fifth of the RHP zero): D = 0.5, L = 10 µH, R = 25 Ω?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A digital PWM counts at 200 MHz for a buck switching at 250 kHz from 48 V.
(a)
How many duty steps per period?
(b)
What output step does each give?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A digital buck from 12 V at 200 kHz has an ADC step of 20 mV at the output.
(a)
What DPWM clock is needed to avoid limit cycles without dithering?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
(b)
With a 100 MHz counter, how many bits of dithering would close the gap?
Check
A digital loop samples once per 200 kHz period, computes in 0.5 µs and crosses over at 20 kHz.
(a)
How much phase does the delay cost?
Check
A 200-step DPWM on a 48 V buck adds a dither pattern lasting 2 to the power 2 periods.
(a)
How many effective steps result?
(b)
What effective output step?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A 100 MHz counter drives a PWM at 100 kHz.
(a)
How many bits of duty resolution is that?
Check
A loop samples at 100 kHz and computes in 3 µs. Its compensator was designed for 50° of margin ignoring delay, at a crossover of 100/10 kHz.
(a)
What margin remains?
Check
DPWM output step: 48 V, 200 kHz, 100 MHz?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Delay phase at 15 kHz: 150 kHz sampling, 1 µs compute?
Check
Effective steps: 128 with 2 bits of dither?
Check
A regulated converter delivers 20 W from a 48 V bus. What incremental input resistance does it present?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
An input filter has = 10 µH and = 4.7 µF. What's its characteristic impedance ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
Where does that filter resonate?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A filter with = 0.7 Ω gets a damping branch with = 2. What's the optimal damping resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
With that optimal damping, how high does the filter's output impedance peak?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A converter takes 30 W from 12 V. With a 10 dB margin under Middlebrook's criterion, how high may the input filter's impedance peak?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A 50 W converter on a 12 V bus has an input filter of 10 µH and 47 µF with optimal parallel damping, = 2.
(a)
What is the magnitude of the converter's input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
How high does the damped filter's output impedance peak?
(c)
What margin does that leave?
Check
Converter input resistance: 10 W at 24 V?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
Optimally damped peak: = 0.5, n = 2?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
for 4.7 µH, 10 µF?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A buck from 12 V with L = 4.7 µH, C = 100 µF, load 4 Ω.
(a)
DC gain of , volts per unit duty?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Resonance?
(c)
Q?
Check
A boost from 5 V at D = 0.5: L = 68 µH, C = 47 µF, load 15 Ω.
(a)
DC duty gain?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Resonance?
(c)
RHP zero?
Check
An output capacitor of 22 µF with 30 mΩ of ESR; and a buck whose output impedance peaks at Q × with Q = 8.
(a)
ESR zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How far does peak above its DC value?
Check
A buck from 9 V to 1.8 V, reference 1 V, ramp 1.8 V; at low frequency its compensated loop gain is 30.
(a)
Uncompensated DC loop gain?
(b)
Output change for a 0.5 V input step, closed loop?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
A type III compensator (zeros at 3 kHz, poles at 100 kHz) at a 60 kHz crossover, where the plant's phase is −165°.
(a)
Compensator phase?
(b)
Phase margin?
Check
A plant with Q = 1.5 at 3 times its resonance; a type II zero at 8 kHz and pole at 200 kHz.
(a)
Plant phase?
(b)
Type II maximum boost?
Check
A plant of flat magnitude 2 near a 30 kHz crossover; and a boost at D = 0.7, L = 47 µH, load 8 Ω.
(a)
Integrator gain for that crossover?
Write units the way you normally would: 1.5 rad/s and 1500 mrad/s are the same answer.
(b)
The boost's crossover limit (a fifth of its RHP zero)?
Check
A converter takes 25 W from 12 V through a filter with = 22 µH, = 47 µF.
(a)
Converter's input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter's ?
(c)
Filter resonance?
Check
Damping a filter with = 0.4 Ω using = 2.
(a)
Optimal ?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Resulting peak?
Check
A 20 W converter on 24 V, needing a 10 dB margin; its filter has = 1 Ω.
(a)
Largest allowed filter peak?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Optimally damped peak with n = 4?
Check
A converter (15 V to 5 V) with open-loop output impedance 8 mΩ and loop gain 15 at low frequency.
(a)
Closed-loop output impedance?
Write units the way you normally would: 1.5 mΩ, 1500 µΩ and 0.0015 Ω are the same answer.
(b)
Closed-loop line-to-output gain?
Check
A buck (L = 6.8 µH, C = 47 µF, R = 2 Ω) switching at 800 kHz.
(a)
Resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Crossover by the tenth-of-switching rule?
(c)
Ratio of crossover to resonance?
Check
A type II compensator must add 45° of phase boost at a 5 kHz crossover, with its zero and pole placed symmetrically, at and .
(a)
What factor k?
(b)
Where is the zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
An output capacitor of 220 µF has 5 mΩ of ESR; the loop crosses over at 40 kHz.
(a)
Where is the ESR zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How much phase does the zero add at crossover?
Check
A digital buck from 12 V switches at 250 kHz with a 100 MHz PWM counter, and dithers over periods.
(a)
How many bits of resolution does the counter give?
(b)
How far does one counter step move the output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(c)
And the effective step with dithering?
Check
Converting 12 V to 1.8 V at 8 A.
(a)
Linear regulator loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Switching converter loss at 0.94?
Check
A converter from 12 V at D = 0.3 delivering 3 A.
(a)
Boost output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Buck-boost output magnitude?
(c)
Inductor current in either?
Check
A buck from 12 V to 1.2 V at 3 A: 10 µH, 800 kHz, 22 µF.
(a)
Inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Output ripple?
Check
A SEPIC from 3 V to 3.3 V at 2 A.
(a)
Duty cycle?
(b)
Switch stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost (inductor resistance 0.02 Ω, load 5 Ω, D = 0.8); a buck from 12 V to 1.2 V with a 0.4 V diode.
(a)
Boost efficiency?
(b)
Buck efficiency from the diode alone?
Check
A MOSFET switching 48 V and 5 A with 25 ns transitions at 300 kHz, = 5 mΩ, D = 0.3.
(a)
Transition loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Conduction loss?
Check
A buck with L = 4.7 µH at 200 kHz, D = 0.4.
(a)
Critical load?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
DCM ratio at K = 0.1?
Check
A flyback with = 0.1 making 12 V from 48 V.
(a)
Duty cycle?
(b)
Switch stress?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A boost at D = 0.4: L = 22 µH, C = 33 µF, load 40 Ω.
(a)
Resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
RHP zero?
Check
A buck from 12 V to 1.8 V, reference 0.8 V, ramp 1.5 V, with a 100 µF output capacitor of 10 mΩ ESR.
(a)
Uncompensated DC loop gain?
(b)
ESR zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A type III compensator (zeros 5 kHz, poles 150 kHz) at a 70 kHz crossover, plant phase −170°.
(a)
Compensator phase?
(b)
Phase margin?
Check
A 30 W converter on 12 V with an input filter of = 0.8 Ω damped with n = 4.
(a)
Converter's input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Optimally damped filter peak?
Check
A diode with 20 nC of recovery charge and a MOSFET with 600 pF of output capacitance, switching 48 V at 200 kHz.
(a)
Recovery loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Capacitance loss?
Check
A boost at 1 A out, D = 0.5, 400 kHz, 47 µF, inductor ripple 0.3 A.
(a)
Output ripple?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Transistor peak current?
Check
Two interleaved buck phases make 1.8 V at D = 0.1, each with 1 µH at 800 kHz, into 200 µF.
(a)
What ripple does the total output current have?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What output voltage ripple results (no ESR)?
Check
A digital buck from 12 V switches at 200 kHz with a 250 MHz PWM counter, takes 0.4 µs to compute each update, and crosses over at 30 kHz.
(a)
How far does one PWM step move the output?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
How much phase does the sampling delay cost at crossover?
Check
A buck from 12 V to 1.2 V has L = 47 µH. What's its inductor current's rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
Check
A converter under peak current-mode control without slope compensation runs at D = 0.6. What's α?
Check
A current-mode converter's inductor current rises at 0.2 A/µs and falls at 0.6 A/µs. What's the least compensating slope that keeps it stable?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
Check
With , what's α for slopes = 0.2 and = 0.6 A/µs?
Check
A current loop has α = −0.6. By what factor has a perturbation's magnitude shrunk after 5 cycles?
Check
A current-mode buck feeds 2 Ω with 22 µF of output capacitance. Where's its dominant control-to-output pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A current-mode buck converts 12 V to 0.3 of that with L = 15 µH.
(a)
What is the current's rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
What is α with ?
Check
Uncompensated α at D = 0.7?
Check
Minimum compensating slope: = 0.1, = 0.3 A/µs?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
Check
Current-mode pole: R = 1 Ω, C = 47 µF?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
What's the reluctance of a 0.5 mm air gap across a 30 mm² core?
Write units the way you normally would: 1.5 A/Wb, 1500 mA/Wb and 0.0015 kA/Wb are the same answer.
Check
A gap-dominated core (200 mm², 0.2 mm gap) has 25 turns. What's its inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A gapped core has 10 turns carrying 1 A across a 1 mm gap. What's the flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
What's the skin depth in copper at 100 kHz?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
How many turns give 47 µH on a 150 mm² core with a 0.3 mm gap?
Check
A ferrite's loss is mW/cm³ with f in kHz and B in tesla. What does a 5 cm³ core lose at 100 kHz and 0.1 T?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A ferrite's loss is mW/cm³ (f in kHz, B in tesla); its core is 5 cm³.
(a)
What does it lose at 200 kHz and 0.05 T?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
(b)
By what factor would doubling the flux swing raise the loss?
Check
Inductance: N = 8, gap 0.3 mm, 300 mm²?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
Flux density: N = 15, I = 2 A, gap 2 mm?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
Copper skin depth at 200 kHz?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
An inductor of 47 µH carries a peak of 3 A on a 2 cm² core with = 0.3 T. How many turns does the flux limit require (before rounding)?
Check
For the same inductor, what gap gives exactly 47 µH?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
What is needed for 22 µH at 5 A peak and 10 A RMS, = 0.35 T, 0.5 W of copper loss and = 0.3?
Check
A core has = 1.5 cm², = 0.6 cm² and MLT = 10 cm. What's its ?
Check
10 turns of the largest wire that fits ( = 0.5, = 2.5 cm²) with MLT = 4 cm carry 3 A RMS. What's the copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A 33 µH inductor with 30 turns on a 1.6 cm² core carries 4 A peak. What's its peak flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
An inductor of 47 µH carries 3 A peak on a core of 2 cm² at = 0.3 T.
(a)
How much energy does it store at peak?
Write units the way you normally would: 1.5 mJ, 1500 µJ and 0.0015 J are the same answer.
(b)
What gap holds it at ?
Check
Turns for the flux limit: 15 µH, 4 A, 0.3 T, 1.5 cm²?
Check
Core : 0.6 cm², 0.9 cm², MLT 9 cm?
Check
Gap: 22 µH, 5 A peak, 0.35 T, 1.5 cm²?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A forward converter applies 48 V to its primary at D = 0.3 and 300 kHz. What volt-seconds does each pulse apply?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
Check
A winding receives 100 µV·s per pulse on a 1.5 cm² core, with peak AC flux density 0.05 T. How many turns does it need (before rounding)?
Check
A winding of 8 turns on a 1 cm² core receives 50 µV·s per pulse. What's the peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
At its optimal flux density, a transformer's core loss is 0.5 W with Steinmetz exponent β = 2.6. What's the total loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A transformer's primary has 10 turns at 0.5 A RMS and its secondary 5 turns at 8 A RMS. What fraction of the window should the primary get?
Check
If a transformer's peak AC flux density is cut to 0.7 of its value, by what factor does its core loss change (β = 2.6)?
Check
A forward converter makes 3.3 V at 20 A from 48 V at D = 0.4.
(a)
What turns ratio ?
(b)
What RMS current does the secondary carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
And the primary?
Check
Volt-seconds: 24 V, D = 0.25, 500 kHz?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
Check
Turns for 40 µV·s, = 0.06 T, 2 cm²?
Check
Primary's window share: 6 turns × 1 A against 6 turns × 15 A?
Check
A current-mode buck from 12 V to 1.2 V with L = 10 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Falling slope?
(c)
α without compensation?
Check
A current-mode boost from 5 V to 30 V with L = 47 µH.
(a)
α without compensation?
(b)
Minimum compensating slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(c)
α with ?
Check
A current loop with α = −0.4; and a current-mode buck feeding 5 Ω with 330 µF.
(a)
Perturbation remaining after 4 cycles?
(b)
Voltage-loop plant pole?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A gap-dominated core: 10 turns, 0.3 mm gap, 150 mm², carrying 8 A peak.
(a)
Inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
Peak flux density?
Check
Copper at 200 kHz; a ferrite with mW/cm³ (f in kHz) at 0.12 T, 4 cm³.
(a)
Skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
Core loss?
Check
An inductor of 15 µH, 4 A peak, = 0.3 T, core 1.4 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
33 µH, 4 A peak, 8 A RMS, = 0.3 T, 0.5 W copper, = 0.35; a core with = 0.8 cm², = 1 cm², MLT = 4 cm.
(a)
Required ?
(b)
Core's ?
Check
12 turns filling the window ( = 0.5, = 2.5 cm²), MLT 5 cm, 4 A RMS.
(a)
Wire area?
(b)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A forward transformer: 36 V at D = 0.3, 250 kHz, = 0.1 T, 0.4 cm².
(a)
Volt-seconds per pulse?
Write units the way you normally would: 1.5 µV·s, 1500 nV·s and 0.0015 mV·s are the same answer.
(b)
Primary turns (before rounding)?
Check
At the optimum a transformer's core loses 0.2 W with β = 2.6.
(a)
Copper loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Core loss if were cut to 0.8 of the optimum?
(c)
Copper loss then?
Check
A transformer: primary 8 turns at 1 A, secondary 4 turns at 12 A; 60 µV·s on a 10-turn winding on 0.5 cm².
(a)
Primary's window share?
(b)
Peak AC flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
An inductor (22 µH, 25 turns, 1.2 cm²) carrying 3 A peak.
(a)
Peak flux density?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
Energy stored at the peak?
Check
A peak current-mode buck makes 5 V from 24 V with 10 µH and a compensating ramp of 0.75 times the falling slope.
(a)
What is α?
(b)
Over how many cycles does a current disturbance shrink a hundredfold?
Check
An inductor of 47 µH carries 2 A peak with = 0.3 T in a gap-dominated core.
(a)
How much energy does it store at peak?
Write units the way you normally would: 1.5 mJ, 1500 µJ and 0.0015 J are the same answer.
(b)
What gap volume must hold that energy?
Check
A winding at 100 kHz needs 1 mm² of copper, made of litz strands two skin depths in diameter.
(a)
What is the skin depth?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
(b)
How many strands of diameter 2δ does it take?
Check
A current has 10 A RMS fundamental, 1 A RMS 3rd harmonic and 2 A RMS 5th. What's its total RMS value?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A current's THD is 48%. What's its distortion factor?
Check
A load has THD 60% and its fundamental lags the sinusoidal voltage by 0°. What's its power factor?
Check
A sinusoidal 120 V source supplies 2 A of fundamental at 35° lag and 4 A of 3rd harmonic. What real power flows?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A rectifier draws unit-height current pulses conducting 90° in each half cycle, centered on the voltage peaks. What's its power factor?
Check
A 120 V sinusoidal source supplies a fundamental of 4 A at 10° lag plus 3 A and 2 A of harmonics. What's the power factor?
Check
A load's current has THD 80%, and its fundamental lags the sinusoidal voltage by 0°.
(a)
What is its distortion factor?
(b)
What is its power factor?
Check
Distortion factor at THD 80%?
Check
RMS of 3, 0.5 and 3 A components?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Power factor: THD 40%, 10° displacement?
Check
A six-pulse bridge runs from 480 V line to line at firing angle 0°. What's its ideal DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A six-pulse bridge with 0.5 mH of source inductance carries 50 A at 60 Hz. How much output voltage does commutation overlap cost?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A single-phase diode bridge with a large DC inductor runs from 230 V RMS. What's its DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A six-pulse bridge carries 200 A DC. What's the RMS of its line current's 5th harmonic?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A thyristor bridge on 480 V is fired at 120°. What's the magnitude of the DC voltage it applies while returning power to the line?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A six-pulse bridge carries 100 A DC (smooth). What's the RMS line current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
An ideal six-pulse bridge carries a smooth 200 A.
(a)
What is its line current's fundamental, RMS?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
And its 5th harmonic?
Check
Six-pulse output: 400 V, α = 15°?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Overlap drop: 0.2 mH, 100 A, 60 Hz?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
5th harmonic RMS at 80 A DC?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A PFC rectifier delivers 100 W from 230 V RMS. What resistance does it emulate?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
What's the peak line current of an ideal 150 W PFC on 120 V RMS?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A boost PFC regulates 385 V from 120 V RMS. What duty cycle does it use when the line is at 80° of its cycle?
Check
A 750 W PFC with a 400 V bus on a 50 Hz line has 1500 µF of bulk capacitance. What's its twice-line ripple, peak to peak?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 600 W supply must hold up for 10 ms while its bus falls from 400 V to 300 V. How much capacitance?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
What's the lowest bus voltage a boost PFC on a 230 V RMS line can regulate?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 300 W boost PFC on 120 V RMS runs a 400 V bus with a 600 µH inductor at 65 kHz.
(a)
What is the peak line current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What inductor ripple does it have at the line's peak?
Check
Emulated resistance: 60 W at 100 V?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
Twice-line ripple: 300 W, 50 Hz, 680 µF, 400 V?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Hold-up capacitance: 250 W, 12 ms, 400 → 320 V?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A half-bridge inverter on a 400 V bus runs sinusoidal PWM at m = 0.5. What's the peak of its output's fundamental?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A full-bridge inverter on 400 V runs at m = 0.5. What's its fundamental's RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A three-phase sinusoidal-PWM inverter on 650 V runs at m = 0.6. What's the line-to-line RMS voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
With third-harmonic injection, what's the most line-to-line RMS voltage a three-phase inverter on 650 V can make without overmodulating?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An inverter on 700 V switches at 5 kHz with 1 µs of dead time. About how large is the average voltage error?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An inverter's carrier runs at 10 kHz and its output at 50 Hz. What's the frequency ratio around whose multiples the switching harmonics cluster?
Check
A full-bridge inverter on a 400 V bus makes 120 V RMS, switching at 20 kHz behind an LC filter with its corner at 2 kHz.
(a)
What modulation index?
(b)
About how much does the filter attenuate the switching frequency?
Check
Three-phase line-to-line RMS: 200 V bus, m = 0.4?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Full-bridge RMS: 100 V, m = 0.6?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Dead-time error: 0.3 µs, 8 kHz, 800 V?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 230 V sinusoidal source supplies 4 A of fundamental at 0° lag plus 1 A and 2.5 A of harmonics.
(a)
RMS current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Real power?
(c)
Power factor?
Check
A current with THD 70% at 5° displacement; and a rectifier drawing unit pulses of 120° per half cycle centered on the voltage peaks.
(a)
Distortion factor?
(b)
Power factor?
(c)
The pulse rectifier's power factor?
Check
A six-pulse thyristor bridge on 480 V at α = 0°, with 0.5 mH of source inductance carrying 400 A.
(a)
Ideal output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Overlap drop?
(c)
Actual output?
Check
A six-pulse bridge carrying 150 A; and a single-phase bridge with a large inductor on 230 V.
(a)
Six-pulse RMS line current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Its 5th harmonic?
(c)
Single-phase bridge output?
Check
A boost PFC: 300 W from 230 V RMS to a 420 V bus.
(a)
Emulated resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Peak line current?
(c)
Duty cycle at 70° of the line cycle?
Check
A 1000 W PFC with 1000 µF on a 400 V bus, 50 Hz line, needing 10 ms of hold-up down to 280 V.
(a)
Twice-line ripple?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Hold-up time it provides?
(c)
Capacitance needed for 10 ms?
Check
An inverter on a 400 V bus, sinusoidal PWM at m = 0.5.
(a)
Half-bridge fundamental peak?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Full-bridge fundamental RMS?
(c)
Three-phase line-to-line RMS?
Check
A three-phase inverter on 700 V must produce 230 V line to line; its dead time is 2 µs at 20 kHz.
(a)
Modulation index needed (sinusoidal PWM)?
(b)
Most it can make with third-harmonic injection?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(c)
Dead-time error?
Check
A thyristor bridge on 480 V fired at 110° carries 1000 A.
(a)
Magnitude of its DC voltage (inverting)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Power returned to the line (ignoring overlap)?
Check
An inverter with a 4 kHz carrier making 50 Hz; and the lowest bus a boost PFC can use on 230 V RMS.
(a)
?
(b)
Minimum PFC bus?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A rectifier drawing 10 A RMS from 120 V in pulses of 90° per half cycle, centered on the voltage peaks.
(a)
Power factor?
(b)
Real power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A three-phase inverter at m = 0.6 on 300 V; a load current with THD 30% from a sinusoidal source.
(a)
Phase (line-to-neutral) RMS voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How far below 1 is the current's distortion factor?
Check
A six-pulse thyristor bridge on 480 V, 50 Hz, fired at 0°, carries 200 A through 0.3 mH of source inductance per phase.
(a)
What is the overlap angle?
(b)
What DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A six-pulse thyristor bridge on 400 V, fired at 20°, carries 400 A through a large DC inductor; ignore overlap.
(a)
What power factor does the line see?
(b)
How much fundamental reactive power does it draw?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
Check
A single-phase full-bridge inverter on 200 V runs sinusoidal PWM at m = 0.6, 60 Hz, with a 20 kHz carrier, into 10 Ω in series with 10 mH.
(a)
What is the output's fundamental, RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What fundamental current flows?
(c)
Around what harmonic number does the first cluster of switching harmonics sit?
Check
A space-vector reference of index m = 0.7 sits 10° into a sector, with a switching period of 100 µs.
(a)
How long is the first active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
(b)
How much time is left for the zero vectors?
Check
A three-phase inverter runs from a 700 V bus.
(a)
What is the largest line-to-line RMS voltage with space-vector modulation (linear range)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And in six-step?
Check
A motor is rated 400 V line to line.
(a)
What DC bus does space-vector modulation need for full voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And sinusoidal PWM?
Check
A 600 V bus feeds a two-level three-phase inverter.
(a)
How long is each active space vector?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the largest reference magnitude in linear modulation?
Check
An inverter runs in six-step.
(a)
What is its 7th harmonic, as a percentage of the fundamental?
Check
A drive switches at 10 kHz. With discontinuous PWM, each leg stops switching for a third of each fundamental cycle.
(a)
What is each leg's average switching frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
for m = 0.5, θ = 15°, = 100 µs?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
Largest linear line-to-line RMS from 560 V with SVM?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Bus for a 380 V motor with SVM?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 20 kW grid inverter at unity power factor feeds a 400 V, 60 Hz line through 10 mH per phase.
(a)
What current does it inject?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What phase voltage must its bridge produce?
Check
An LCL filter has = 2 mH, = 0.25 mH and C = 20 µF; the inverter switches at 16 kHz.
(a)
Where is its resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How much more does it attenuate the switching frequency than a single inductor of the same total, with a stiff grid?
Check
An inverter rated 10 kVA delivers 0.6 of that as real power.
(a)
How much reactive power can it add?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
Check
A grid inverter for a 400 V line needs a 5% margin over the minimum DC link with space-vector modulation, ignoring the filter drop.
(a)
What DC link voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Each phase of a grid inverter carries 10 A RMS at 60° from its 230 V phase voltage.
(a)
What real power?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
(b)
What reactive power?
Check
An LCL filter's resonance should sit between ten times the 50 Hz grid frequency and half the 4 kHz switching frequency.
(a)
What resonance is at the geometric middle of that range?
Write units the way you normally would: 1.5 Hz, 1500 mHz and 0.0015 kHz are the same answer.
Check
Current for 3 kW at unity pf on 208 V?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
LCL resonance: 1.5 mH, 0.3 mH, 15 µF?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
Reactive capacity of an 8 kVA inverter at 0.7 real loading?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
Check
A cascaded H-bridge drive for a 4.16 kV motor uses cells with 600 V DC links.
(a)
How many cells per phase are needed?
(b)
How many levels does each phase have?
Check
A cascaded H-bridge phase has 5 cells, each switching at 500 Hz with unipolar PWM and phase-shifted carriers.
(a)
At what frequency does the output ripple appear?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
By how much are the carriers shifted?
Check
A 5-level diode-clamped converter runs from a 1500 V bus.
(a)
What does each switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An MMC's DC link is 640 kV pole to pole, built from 1.6 kV submodules, with 10% redundancy.
(a)
How many submodules does each arm need?
Check
A converter with 3 levels per phase on a 1200 V bus switches each step in 200 ns.
(a)
What dv/dt does the load see?
Write units the way you normally would: 1.5 V/µs, 1500 mV/µs and 0.0015 kV/µs are the same answer.
Check
A cascaded H-bridge phase has 4 cells.
(a)
How many levels does the line-to-line voltage have?
Check
Phase levels with 4 H-bridge cells?
Check
Device blocking voltage, 3-level on 1000 V?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Ripple frequency: 4 cells at 400 Hz, unipolar?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A space-vector reference of index 0.6 sits 12° into its sector, with a 125 µs switching period.
(a)
How long is the first active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
(b)
And the second?
(c)
How much time do the zero vectors share?
Check
A space-vector reference of index 0.5 points at 130° (sector 1 runs from 0° to 60°), with a 100 µs period.
(a)
Which sector is it in?
(b)
How long is the sector's second active vector applied?
Write units the way you normally would: 1.5 µs, 1500 ns and 0.0015 ms are the same answer.
Check
A motor is rated 400 V line to line; its drive's bus needs 5% margin over the minimum.
(a)
What bus voltage does space-vector modulation need?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
And sinusoidal PWM?
(c)
And six-step, where the line-to-line fundamental is ?
Check
An inverter on a 650 V bus must produce 300 V line to line.
(a)
What space-vector modulation index does it need?
(b)
What sinusoidal PWM index would it need?
Check
A drive's switches lose 120 W in switching at 8 kHz with continuous space-vector modulation; switching loss is 0.65 of the total semiconductor loss.
(a)
What switching loss does discontinuous PWM leave at the same carrier frequency?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What total semiconductor loss results?
(c)
Alternatively, what carrier frequency would discontinuous PWM allow for the original switching loss?
Check
A grid inverter on a 480 V, 50 Hz line supplies 10 kW and 8 kvar through 3 mH per phase.
(a)
What current does each phase carry?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What phase voltage must the bridge make?
(c)
What is the least DC link that space-vector modulation can do it with?
Check
An LCL filter has = 1 mH, = 0.3 mH and C = 15 µF; its inverter switches at 20 kHz.
(a)
Where is its resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
How much better than a single inductor of the same total does it attenuate the switching frequency (undamped, stiff grid)?
(c)
What series damping resistor equals a third of the capacitor's reactance at resonance?
Check
An LCL filter with = 2 mH and = 0.25 mH must resonate between ten times the 60 Hz grid frequency and half the 16 kHz switching frequency.
(a)
What is the largest capacitance allowed?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
And the smallest?
Check
A 30 kVA grid inverter on 400 V, 60 Hz has filter capacitors of 20 µF per phase, connected line to neutral.
(a)
How much reactive power do the capacitors draw?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
(b)
What percentage of the rating is that? (Designs usually keep it under 5%.)
Check
An inverter's bridge puts 80 V RMS of ripple at its 10 kHz switching frequency into an LCL filter with = 2 mH, = 1 mH and C = 10 µF, feeding a stiff grid; its rated current is 20 A.
(a)
What ripple current reaches the grid?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What percentage of rated current is that? (Grid codes typically allow 0.3% at these frequencies.)
Check
An inverter rated 20 kVA supplies real power at 0.5 of its rating.
(a)
How much reactive power can it add?
Write units the way you normally would: 1.5 kvar, 1500 var and 0.0015 Mvar are the same answer.
(b)
At what power factor is it then running?
Check
A cascaded H-bridge drive for a 6.6 kV motor uses 640 V cells switching at 500 Hz with unipolar PWM and phase-shifted carriers.
(a)
How many cells per phase?
(b)
How many levels does the line-to-line voltage have?
(c)
At what frequency does the output ripple appear?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A diode-clamped inverter with 3 levels runs from a 1500 V bus, with 300 ns switching edges.
(a)
What does each switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What dv/dt does the motor cable see?
Check
An MMC's DC link is 320 kV pole to pole, built from 1.6 kV submodules, each with 15 mF of capacitance.
(a)
How many submodules does each arm need at least?
(b)
How much energy do all six arms' capacitors store?
Write units the way you normally would: 1.5 MJ, 1500 kJ and 0.0015 GJ are the same answer.
Check
A drive runs a motor in six-step from a 650 V bus at 50 Hz; the motor's leakage inductance is 5 mH per phase.
(a)
What is the phase voltage's 5th harmonic, RMS? (The fundamental is .)
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What 5th harmonic current does it drive through the leakage inductance?
Check
A resonant tank has = 20 µH and = 10 nF. What's its resonant frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A bridge rectifier with a capacitive filter feeds 50 Ω. What resistance does it present to a sinusoidal tank current?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A series resonant converter has = 10 µH, = 22 nF and an 80 Ω load. What's its Q?
Check
A series resonant converter with Q = 1 runs at F = 0.7. What's its voltage gain?
Check
A series resonant converter with Q = 1 needs a gain of 0.6. What normalized frequency above resonance does it run at?
Check
A half-bridge drives a tank at resonance from a 200 V bus through a transformer of ratio 0.05. What's the peak of the fundamental the secondary sees?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A series resonant converter feeds 20 Ω through a capacitively filtered bridge rectifier. Its tank must resonate at 500 kHz with Q = 0.5.
(a)
What resistance does the rectifier present to the tank?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What ?
(c)
What ?
Check
Resonant frequency: 8 µH, 15 nF?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
SRC gain: Q = 0.4, F = 1.1?
Check
Rectifier's equivalent resistance for 24 Ω?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A MOSFET with 300 pF of output capacitance switches 48 V at 1000 kHz, hard. What does its capacitance cost at turn-on?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A leg has 250 pF per switch on 200 V. If an inductor alone must swing the node with 6 A, how much inductance does ZVS need?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A steady 10 A swings a switch node across 100 V, with 100 pF on each switch. How long does the transition take?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A synchronous buck on 48 V with 100 pF switches and a 50 µH inductor wants ZVS. How much reverse current must flow when the low-side switch turns off?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A phase-shifted full bridge on 400 V at 100 kHz has 5 µH of leakage carrying 3 A on the primary. What duty cycle is lost to current reversal?
Check
An inductor of 20 µH rings with a leg's two 100 pF capacitances. What's the longest a resonant transition can take?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
An LLC reflects 200 V onto a magnetizing inductance of 100 µH at 250 kHz; its switches have 400 pF each and the bus is 2 × 200 V.
(a)
What magnetizing current is available at each transition?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
How long does it take to swing the node?
Check
Capacitive loss: 150 pF, 100 V, 500 kHz?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
ZVS current: 200 V, 150 pF, 30 µH?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Duty-cycle loss: 3 µH, 4 A, 150 kHz, 400 V?
Check
A device dissipates 25 W with = 0.6 K/W and a 0.1 K/W pad. What heat sink keeps its junction at 110 °C in 55 °C air?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
Check
A device dissipates 15 W through a total of 4 K/W to 25 °C air. What's its junction temperature?
Check
A MOSFET carries 30 A RMS with 8 mΩ at 25 °C (rising 0.6% per kelvin), through 2 K/W to 60 °C air. What's its steady junction temperature?
Check
A diode with a 0.7 V threshold and 40 mΩ slope resistance carries 5 A average and 25 A RMS. What's its conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A 100 W pulse lasting 20 ms hits a device whose thermal path is 0.5 K/W with a 30 ms time constant. How much does the junction rise?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
4 identical MOSFETs of 5 mΩ share 50 A RMS. What's their total conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A MOSFET has 20 mΩ at 25 °C, rising 0.004 per kelvin, on a 6 K/W path to 40 °C air, carrying 20 A RMS.
(a)
At what current would it run away?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What junction temperature does it reach at 20 A, if it's stable?
Check
Heat sink: 8 W, 100 °C limit, 50 °C air, = 0.8, pad 0.2 K/W?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
Check
Diode loss: 0.9 V, 60 mΩ, 4 A avg, 30 A RMS?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Pulse rise: 30 W, 20 ms, 0.8 K/W, τ = 40 ms?
Write units the way you normally would: 1.5 K and 1500 mK are the same answer.
Check
An electrolytic rated 5000 h at 85 °C runs with its core at 80 °C.
(a)
What life should it have?
(b)
How many years of continuous operation is that?
Check
A capacitor carries 1.5 A RMS of ripple through 20 mΩ of ESR, with 30 K/W from core to surroundings.
(a)
How much does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
By what factor does the self-heating multiply its life?
Check
An X5R ceramic rated 22 µF keeps 0.3 of its capacitance at the working DC bias, and loses another 15% at its operating temperature.
(a)
What capacitance does the circuit actually get?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
Check
A board has 20 parts at 5 FIT, 6 parts at 150 FIT and 1 parts at 100 FIT.
(a)
What is its total failure rate?
(b)
What is its MTBF?
(c)
What fraction fail within five years of continuous use?
Check
A failure mechanism has activation energy 0.7 eV.
(a)
By what factor does it speed up from 25 °C to 125 °C?
Check
An electrolytic rated 5000 h at 105 °C spends 0.7 of its time at 45 °C and the rest at 95 °C.
(a)
What life does Miner's rule give?
Check
Life of a 3000 h, 105 °C part at 55 °C?
Check
MTBF at 300 FIT?
Check
Ripple loss: 1 A RMS, 40 mΩ ESR?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A MOSFET with 60 nC of gate charge is driven to 5 V at 1000 kHz. How much power does the drive take?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A MOSFET's Miller charge is 20 nC and its plateau sits at 5 V. Driven from 15 V through 2 Ω, how long does its drain voltage take to fall?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
A high-side gate needs 60 nC and its driver draws 100 µA over on-times up to 50 µs. How much bootstrap capacitance keeps the droop to 1 V?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
Check
A power loop with 20 nH of inductance has its 10 A cut off in 20 ns. How much does the switch voltage overshoot?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A 10 nH power loop rings with 50 pF of switch capacitance. At what frequency?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
An off MOSFET has 5 pF of gate–drain capacitance and 4 Ω from gate to its driver's low output. Its drain rises at 100 V/ns. How much does its gate rise?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A power loop of 20 nH rings with 200 pF of switch capacitance; an RC snubber with four times that capacitance is added, at 400 V and 300 kHz.
(a)
At what frequency does it ring?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
(b)
What snubber resistance damps it?
(c)
What does the snubber dissipate?
Check
Drive power: 15 nC, 6 V, 2000 kHz?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
Plateau time: 8 nC, 3 Ω, 15 V drive, 6 V plateau?
Write units the way you normally would: 1.5 ns, 1500 ps and 0.0015 µs are the same answer.
Check
Overshoot: 3 nH, 15 A in 15 ns?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A LISN measures 3 mV at one frequency. What's that in dBµV?
Check
A switch node's edges take 10 ns. Above what frequency does its spectrum fall 40 dB per decade?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
Check
A switch node with 50 pF to chassis swings 48 V in 50 ns. What common-mode current flows during the edge?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A harmonic at 200 kHz needs 40 dB of attenuation from a second-order LC filter. Where must the filter's corner be?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
An input filter needs a 10 kHz corner with a 2.2 µF capacitor. What inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
A switch node swings from 0 to 48 V at duty cycle 0.3. What's the amplitude of its harmonic number 3?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
An input filter must attenuate 150 kHz by 40 dB, using a 10 µF capacitor.
(a)
Where must its corner be?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
What inductance does that need?
Check
0.1 mV in dBµV?
Check
Filter corner: 50 dB at 150 kHz?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
CM current: 20 pF, 100 V in 30 ns?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A series resonant converter with = 10 µH, = 22 nF and an 80 Ω load behind a bridge rectifier, run at F = 1.6.
(a)
Resonant frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Q?
(c)
Gain?
Check
A series resonant converter with Q = 0.5; a half-bridge on 400 V driving a tank at resonance through a ratio of 0.1.
(a)
Normalized frequency for gain 0.7 above resonance?
(b)
Peak fundamental at the secondary?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A half-bridge leg on 200 V with 100 pF per switch at 500 kHz.
(a)
Capacitive loss per switch if hard-switched?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Inductance needed for ZVS with 6 A?
(c)
Transition time at a steady 6 A?
Check
A phase-shifted full bridge on 400 V at 150 kHz, with 3 µH of leakage, 4 A primary current and 150 pF per switch.
(a)
Duty-cycle loss?
(b)
Least current for ZVS from the leakage alone?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A device dissipating 10 W, = 0.6 K/W, a 0.1 K/W pad, 50 °C air.
(a)
Heat sink for a 110 °C junction?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
(b)
Junction temperature on a 1 K/W heat sink?
Check
A MOSFET carrying 20 A RMS with 8 mΩ at 25 °C (α = 0.006/K) on a 2 K/W path to 60 °C air.
(a)
Junction temperature?
(b)
Runaway current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A diode with a 0.8 V threshold and 40 mΩ slope at 5 A average, 30 A RMS; a 50 W pulse of 2 ms on a 0.5 K/W, τ = 15 ms device.
(a)
Diode conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Junction rise from the pulse?
Check
A MOSFET with = 20 nC and = 30 nC, plateau 4 V, driven from 10 V through 2 Ω at 500 kHz.
(a)
Drive power?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
(b)
Turn-on Miller time?
(c)
Turn-off Miller time (driven to 0 V)?
Check
A high-side gate needing 30 nC, a driver drawing 100 µA, on-times up to 40 µs; a low-side off switch with 2 Ω and 10 pF of at 20 V/ns.
(a)
Bootstrap capacitance for 1 V of droop?
Write units the way you normally would: 1.5 nF, 1500 pF and 0.0015 µF are the same answer.
(b)
Induced gate voltage?
Check
A 10 nH power loop cuts 10 A in 15 ns and rings with 800 pF.
(a)
Overshoot from ?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Ringing frequency?
(c)
Energy in the loop inductance?
Check
A switch node at 100 kHz, duty 0.3, 25 ns edges, swinging 48 V, with 100 pF to chassis.
(a)
First corner of the spectrum?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Second corner?
(c)
Common-mode current during an edge?
Check
A harmonic at 150 kHz needs 45 dB of attenuation from an LC filter with 4.7 µF; a LISN reads 20 mV.
(a)
Filter corner?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Inductance?
(c)
The LISN reading in dBµV?
Check
An LLC converter has and Q = 0.3, and runs at F = 1.3.
(a)
What gain does the first-harmonic approximation give?
Check
A half bridge on 48 V with 100 pF per switch swings its node using the current in a 10 µH inductor, which is 2 times the least current that can do it.
(a)
What current is that?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
How long does the transition take?
Check
4 devices, each dissipating 5 W with 1.2 K/W from junction to sink, share a heat sink of 0.8 K/W in 35 °C air.
(a)
How hot is the heat sink?
(b)
What is each junction's temperature?
Check
Modules with = 38 V at 25 °C (rising 0.28% per kelvin of cooling) must keep an open string below 1500 V at a site that reaches 35 °C below 25 °C.
(a)
What is each module's cold open-circuit voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How many modules can a string have?
Check
A string of 24 modules has = 32 V each at 25 °C, falling 0.35% per kelvin; it runs 45 K above 25 °C.
(a)
What is the string's hot MPP voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A tracker measures 8 A at 25 V with incremental conductance −0.5 S.
(a)
What is dP/dV?
Write units the way you normally would: 1.5 W/V, 1500 mW/V and 0.0015 kW/V are the same answer.
(b)
What incremental conductance would mark the MPP?
Check
A module delivers 330 W at its MPP, with = 37 V and = 10.5 A.
(a)
What is its fill factor?
Check
A 300 W (at 25 °C) array runs 40 K hotter, with power falling 0.35% per kelvin.
(a)
What does it deliver?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
A boost stage takes 12 module(s) in series at 30 V each up to a 200 V bus.
(a)
What duty cycle does it run at?
Check
Modules per string: 40 V, 20 K below 25 °C, limit 1500 V?
Check
dP/dV at 6 A, 28 V, dI/dV = −0.4 S?
Write units the way you normally would: 1.5 W/V, 1500 mW/V and 0.0015 kW/V are the same answer.
Check
Fill factor: 280 W, 38 V, 11 A?
Check
An electrolytic rated 5000 h at 85 °C sits in 70 °C air and carries 2.5 A RMS of ripple through 30 mΩ of ESR, with 12 K/W from core to air.
(a)
What is its core temperature?
(b)
What life should it have?
Check
An electrolytic rated 3000 h at 105 °C runs at 50 °C for 0.6 of its life and at 100 °C for the rest.
(a)
What life does Miner's rule give?
(b)
What percentage of the wear happens in the hot periods?
Check
A converter has 30 small parts at 2 FIT, 8 power devices at 100 FIT and 1 electrolytics at 150 FIT.
(a)
What is its failure rate?
(b)
What is its MTBF?
(c)
What percentage fail within ten years of continuous use?
Check
A qualification test runs parts at 150 °C for 2000 hours. The failure mechanism has an activation energy of 0.7 eV; in the field the parts run at 40 °C.
(a)
What is the acceleration factor?
(b)
How many years of field use does the test represent?
Check
A rail needs 47 µF of effective capacitance. Its 22 µF X5R ceramics keep 0.35 of their capacitance at the working bias and 0.9 at the operating temperature.
(a)
How much nominal capacitance is needed?
Write units the way you normally would: 1.5 µF, 1500 nF and 0.0015 mF are the same answer.
(b)
How many parts?
Check
A DC link carries 6 A RMS of ripple; its capacitors are each rated 1.2 A RMS at the frequency and temperature of use, with 90 mΩ of ESR.
(a)
How many in parallel does the ripple rating require?
(b)
What do they dissipate in total?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
Check
Modules with = 41 V at 25 °C (rising 0.27% per kelvin of cooling) go into strings for an inverter limited to 1500 V; the site's coldest morning is 40 K below 25 °C.
(a)
What is a module's coldest open-circuit voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How many modules can a string have?
Check
An inverter tracks the maximum power point only above 550 V. Its modules have = 34 V at 25 °C, falling 0.35% per kelvin, and run 45 K hotter on summer afternoons.
(a)
What is a module's hot ?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the fewest modules a string can have?
Check
An array of 2 strings of 16 modules, each 450 W at 25 °C and full sun, runs 20 K hotter in 0.6 of full sun; power falls 0.4% per kelvin.
(a)
What does the array deliver?
Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.
Check
A boost stage holds 2 module(s) in series, each at 30 V and 400 W at its MPP, and feeds a 400 V bus.
(a)
What duty cycle does it run at?
(b)
What current does its inductor carry on average?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A tracker measures 7 A at 26 V with an incremental conductance of −0.6 S.
(a)
What is dP/dV?
Write units the way you normally would: 1.5 W/V, 1500 mW/V and 0.0015 kW/V are the same answer.
(b)
What incremental conductance would mark the MPP at this operating point?
Check
A module delivers 350 W at its MPP, with = 38 V and = 11 A.
(a)
What is its fill factor?
Check
A 60-cell module has three bypass diodes, one across each group of 20 cells; its is 30 V. One cell in a string of 12 such modules is shaded, so its group is bypassed through a diode dropping 0.7 V.
(a)
What MPP voltage does the string now have (taking the unshaded groups' voltage as unchanged)?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What percentage of the string's power is lost, at unchanged current?
Check
A device dissipates 10 W through 0.8 K/W (junction to sink) and a 0.8 K/W heat sink into 50 °C air. Its dominant failure mechanism has an activation energy of 0.6 eV.
(a)
What is its junction temperature?
(b)
How many times faster does it fail than with a heat sink of half the resistance?
Check
A product with a failure rate of 300 FIT is in service in 20000 units, each running 16 hours a day.
(a)
How many field failures should the fleet see per year?
(b)
What percentage of the units fail randomly over a ten-year service life?
Check
Inductor ripple of a buck: 12 V in, D = 0.2, 22 µH, 500 kHz?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
Output ripple: 0.3 A of inductor ripple, 22 µF, 400 kHz?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
Check
Overshoot of the averaged buck after a duty step: 10 µH, 22 µF, 5 Ω?
Check
Buck inductance: 12 V to 1 V, 10 A, 1000 kHz, ripple fraction 0.2?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
Check
K factor for 130° of boost (type III)?
Check
Type III zeros for crossover at 50 kHz with K = 10?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A boost from 12 V at D = 0.3, with 80 mΩ of inductor resistance, feeding 20 Ω.
(a)
Ideal output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Output with the inductor's resistance?
(c)
Efficiency?
Check
A buck from 12 V at D = 0.3, with 5 µH at 200 kHz feeding 10 Ω.
(a)
K?
(b)
Conversion ratio (it's in DCM, since K < 1 − D)?
(c)
Output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A flyback from 48 V with turns ratio n = 0.1 at D = 0.45.
(a)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Switch voltage while off (no leakage spike)?
Check
A buck's filter: 4.7 µH, 22 µF with 30 mΩ of ESR, feeding 5 Ω.
(a)
Resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Q?
(c)
ESR zero?
Check
A boost at D = 0.5 feeding 5 Ω through 22 µH.
(a)
Right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Highest crossover by the one-fifth rule?
Check
A regulated converter draws 10 W from a 12 V input through an LC filter of 22 µH and 100 µF.
(a)
Magnitude of the converter's negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter's characteristic impedance?
(c)
Their ratio (it must be well below 1)?
Check
A buck's high-side MOSFET: 12 V, 5 A, 20 mΩ, D = 0.5, 5 ns rise and fall, 200 kHz, 200 pF output capacitance.
(a)
Conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Overlap loss?
(c)
Total with the capacitive loss?
Check
A PFC rectifier with efficiency 0.97 draws from 230 V RMS to feed an 800 V bus; a three-phase inverter on that bus delivers 1000 W at 300 V line to line.
(a)
Line current RMS (unity power factor)?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Inverter modulation index (sinusoidal PWM)?
(c)
Inverter output current per phase (unity power factor)?
Check
A series resonant converter: = 10 µH, = 22 nF, a 40 Ω load behind a bridge, run at F = 1.5.
(a)
Equivalent load?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Switching frequency?
(c)
Gain?
Check
A MOSFET losing 0.5 W in conduction and 0.5 W in switching, with 3 K/W to 50 °C air, driven with 20 nC to 10 V at 100 kHz.
(a)
Junction temperature?
(b)
Gate-drive power?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A converter drawing 20 W from 48 V needs 40 dB of attenuation at 150 kHz from an LC filter with 10 µF.
(a)
Corner?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Inductance?
(c)
Ratio of the filter's to the converter's ?
Check
A forward converter from 36 V, turns ratio 0.15, D = 0.45, 250 kHz, = 0.06 T on a 0.4 cm² core.
(a)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Primary turns (before rounding)?
Check
Two interleaved boost phases run from 48 V at D = 0.15, each with 100 µH at 100 kHz.
(a)
What is each phase's inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What ripple does the total input current have?
Check
A DC-link electrolytic rated 4000 h at 105 °C sits in 45 °C air, carrying 3 A RMS through 60 mΩ of ESR with 10 K/W to the air.
(a)
How many years of continuous use should it last?
Check
A transformer's core loses 20 W and its copper 0.001/ W.
(a)
What flux density minimizes the total?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
What is the total loss there?
Check
Design a buck from 24 V to 1.2 V at 15 A and 500 kHz, with inductor ripple 0.2 of the load current and at most 10 mV of output ripple (ignoring ESR).
(a)
What inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
What capacitance?
(c)
What RMS current does the high-side switch carry?
Check
Design a boost from 5 V to 24 V at 2 A out and 400 kHz, with inductor ripple 0.3 of the inductor's current and at most 50 mV of output ripple.
(a)
What is the inductor's average current?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What inductance?
(c)
What output capacitance, given that it alone supplies the load during each on-time?
Check
A flyback in continuous conduction makes 5 V from 160 V with = 0.5.
(a)
What duty cycle does it run at?
(b)
What does the switch block, before any leakage spike?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A flyback runs in the discontinuous mode from 170 V at D = 0.3 and 100 kHz, delivering 40 W.
(a)
What primary inductance gives that power?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
What is the primary's peak current?
Check
A forward converter with a 1:1 reset winding makes 12 V from an input that ranges from 200 V to 1.5 times that, reaching D = 0.45 at the lowest input.
(a)
What turns ratio ?
(b)
What duty cycle does it run at the highest input?
(c)
What must the switch block?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A synchronous buck from 12 V to 1.8 V at 20 A and 300 kHz has a 12 mΩ high-side and a 2 mΩ low-side switch, 5 ns edges, and 10 nC of gate charge per switch driven from 5 V.
(a)
What is the conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is the high-side switch's overlap loss?
(c)
What efficiency results, counting the gate drive too?
Check
A voltage-mode buck from 12 V has a 1 V PWM ramp and an LC corner at 10 kHz; it should cross over at 50 kHz.
(a)
What is the plant's gain at crossover (well above the corner, ignoring ESR)?
(b)
What gain must the compensator have there?
Check
A digitally controlled converter switches at 250 kHz with 1.5 µs of computation delay and crosses over at 5 kHz; its compensator was designed in continuous time for 65° of phase margin.
(a)
How much phase does the digital delay cost at crossover?
(b)
What phase margin is left?
Check
A digital buck from 12 V switches at 200 kHz. Its 12-bit ADC spans 3.3 V and sees the output through a divider of ratio 0.25.
(a)
What output change does one ADC step represent?
Write units the way you normally would: 1.5 mV, 1500 µV and 0.0015 V are the same answer.
(b)
What PWM clock is needed for a PWM step finer than that?
Check
A peak current-mode boost makes 15 V from 5 V with 22 µH.
(a)
What is the inductor current's falling slope ?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
What compensating ramp makes the current loop stable at any duty cycle, by the usual choice?
(c)
What is α with that ramp?
Check
A 200 W regulated converter runs from 12 V behind an input filter damped by with = 4.
(a)
What is the magnitude of the converter's negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What is the largest characteristic impedance that keeps the filter's peak 6 dB below it?
Check
An inductor of 33 µH carries 4 A peak and 8 A RMS, with = 0.3 T, 0.5 W of copper loss and = 0.4. The chosen core has = 0.5 cm².
(a)
What core geometry constant is required?
(b)
How many turns on the chosen core?
(c)
What gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A forward converter's transformer sees 100 V for D = 0.3 of each 400 kHz period on a core of 0.4 cm², designed for = 0.12 T; the output is 5 V.
(a)
How many primary turns?
(b)
How many secondary turns (before rounding)?
(c)
What peak AC flux density do the rounded primary turns give?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
Check
A MOSFET of 25 mΩ at 25 °C (α = 0.008 per kelvin) carries 10 A RMS through 3 K/W to 40 °C air.
(a)
What junction temperature does it settle at?
(b)
Above what current would it run away?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
Check
A buck from 24 V to 5 V rated 10 A at 150 kHz, with a diode, must stay in continuous conduction down to 0.2 of full load.
(a)
What is the least inductance?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
What ripple, as a fraction of full-load current, does it then have at full load?
Check
A 750 W PFC stage of efficiency 0.94 runs from 230 V RMS at 50 Hz onto a 400 V bus, which must hold up the load for 10 ms while falling to 280 V.
(a)
What RMS current does it draw from the line?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What bulk capacitance does hold-up require?
(c)
What peak-to-peak ripple does that capacitor have at twice line frequency?
Check
A boost PFC delivering 500 W at efficiency 0.95 from 100 V RMS to a 400 V bus switches at 100 kHz; its inductor ripple at the line's peak should be 0.4 of the peak current.
(a)
What is the line current's peak?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What inductance gives that ripple at the line's peak?
Check
A drive rectifies a 400 V, 50 Hz line with a six-pulse diode bridge through 0.3 mH of line inductance, carrying 150 A of DC current, and feeds a space-vector inverter for a 460 V motor.
(a)
What DC bus does the rectifier give?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is the most line-to-line voltage the inverter can give the motor without overmodulating?
(c)
What percentage of the motor's rated voltage is that?
Check
A six-pulse rectifier on 400 V delivers 75 kW to its DC side at firing angle 15°, with a large DC inductor; ignore overlap.
(a)
What DC current flows?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is the line current's fundamental, RMS?
(c)
What is its 7th harmonic?
Check
A 22 kW motor (output) rated 400 V has efficiency 0.95 and power factor 0.86; its inverter runs from a 600 V bus with space-vector modulation.
(a)
What current does it draw at full load?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What modulation index does it run at?
Check
A drive with 2 µs of dead time switches at 4 kHz on a 650 V bus. It runs a 460 V motor at 0.05 of rated speed and voltage (constant V/f).
(a)
About how large is the average voltage error the dead time causes?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
What is that as a percentage of the phase voltage's peak at that speed?
Check
A half-bridge LLC converter makes 12 V at 1000 W from 380 V, running at its series resonance 250 kHz at nominal input, with Q = 0.3 at full load.
(a)
What turns ratio gives unity gain at resonance?
(b)
What load resistance does the tank see, referred to the primary?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(c)
What resonant inductance?
Check
A series resonant converter with Q = 1 and resonance at 200 kHz has unity gain at its lowest input; its input rises to 1.2 times that.
(a)
What normalized frequency does it need at the highest input (first-harmonic approximation)?
(b)
What switching frequency is that?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A buck from 48 V at D = 0.25 carries 8 A and must reach −3 A each cycle for zero-voltage turn-on (triangular current mode) at 100 kHz.
(a)
What inductance gives that ripple?
Write units the way you normally would: 1.5 µH, 1500 nH and 0.0015 mH are the same answer.
(b)
What is the inductor's peak current?
Check
A switch node swings 400 V at 250 kHz with duty 0.2 and 20 ns edges; it has 20 pF to the grounded chassis.
(a)
Where is the spectrum envelope's first corner?
Write units the way you normally would: 1.5 MHz, 1500 kHz and 0.0015 GHz are the same answer.
(b)
And its second?
(c)
What common-mode current flows to the chassis during each edge?
Check
A twelve-pulse rectifier draws 500 kW from a 4.16 kV line at unity displacement; ignore overlap.
(a)
What is the line current's fundamental, RMS?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What is its lowest harmonic?
Check
A grid inverter must deliver 250 kW while running at power factor 0.85 on a 600 V line.
(a)
What apparent power rating does it need?
Write units the way you normally would: 1.5 kVA, 1500 VA and 0.0015 MVA are the same answer.
(b)
What current rating?
Check
A transformerless solar inverter feeds a 400 V line by space-vector modulation straight from its string, needing 5% margin over the minimum DC link. Its modules have = 37 V at 25 °C, falling 0.4% per kelvin, and reach 40 K above 25 °C.
(a)
What is the lowest string voltage it can work from?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
How many modules must a string have at least?
Check
An inverter delivers 50 kW at efficiency 0.97; its power module (junction limit 175 °C) has 0.05 K/W junction to case and 0.05 K/W case to sink, in 50 °C air.
(a)
What does it dissipate?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
What is the most thermal resistance the heat sink can have?
Check
A phase-shifted full bridge on 380 V switches at 50 kHz with 20 µH of leakage and 100 pF per switch; its full-load primary current is 20 A.
(a)
What primary current does the leakage alone need to swing a leg's node for zero-voltage switching?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Below what percentage of full load does it lose zero-voltage switching?
(c)
What duty cycle does it lose at full load?
Check
A buck from 24 V to 1.8 V with 10 µH and 22 µF at 500 kHz.
(a)
Duty cycle?
(b)
Inductor ripple, peak to peak?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(c)
Output ripple?
Check
A buck-boost (inverting) from 5 V at D = 0.4, delivering 4 A.
(a)
Output magnitude?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Average inductor current?
(c)
Switch voltage while off?
Check
A boost from 12 V at D = 0.4 with 100 mΩ of inductor resistance and a 30 Ω load.
(a)
Efficiency?
(b)
Output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A buck from 12 V at D = 0.4: 1 µH, 100 kHz, 60 Ω.
(a)
K?
(b)
Output in DCM?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
Isolated converters from 48 V with turns ratio 0.1 at D = 0.4.
(a)
Forward converter's output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Flyback's output?
Check
A boost at D = 0.3 with 10 µH, 220 µF and a 15 Ω load.
(a)
Resonant frequency of the small-signal model?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
RHP zero?
Check
A lead compensator with its zero at 2 kHz and pole at 20 kHz; a type III with zeros at 2 kHz and poles at 20 kHz evaluated at 15 kHz.
(a)
Maximum lead of the single zero–pole pair?
(b)
Type III phase at 15 kHz?
Check
A converter regulates 20 W from 28 V behind an LC filter of 47 µH and 100 µF.
(a)
Magnitude of its negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter resonance?
Check
A current-mode boost from 5 V to 30 V with 22 µH.
(a)
Rising slope?
Write units the way you normally would: 1.5 A/µs, 1500 mA/µs and 0.0015 kA/µs are the same answer.
(b)
Minimum compensating slope?
Check
An inductor of 47 µH carrying 3 A peak, = 0.3 T, core 1.2 cm².
(a)
Turns (before rounding)?
(b)
Gap?
Write units the way you normally would: 1.5 mm, 1500 µm and 0.0015 m are the same answer.
Check
A load draws a fundamental of 3 A at 35° lag from 120 V RMS, with THD 90%.
(a)
Real power?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Power factor?
Check
A six-pulse thyristor bridge on 480 V at α = 15° carrying 300 A with 0.4 mH of source inductance (60 Hz).
(a)
DC output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
5th-harmonic line current (RMS)?
Check
A boost PFC delivers 300 W from 120 V RMS (50 Hz) to a 400 V bus with 680 µF.
(a)
Emulated resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Bus ripple, peak to peak?
Check
A three-phase inverter on 400 V at m = 0.7, 2 µs dead time at 20 kHz.
(a)
Line-to-line RMS?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Dead-time voltage error?
Check
A half-bridge with 100 pF per switch on 400 V at 300 kHz; an inductor of 40 µH available to swing the node.
(a)
Capacitive loss per switch if hard-switched?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Current needed for ZVS?
Check
A switch dissipating 5 W ( = 1 K/W, pad 0.5 K/W) in 35 °C air; its switch node's edges take 5 ns.
(a)
Heat sink for a 110 °C junction?
Write units the way you normally would: 1.5 K/W and 1500 mK/W are the same answer.
(b)
Where does the switch node's spectrum begin falling 40 dB per decade?
A kind of problem counts as solid once you've got it right on the first try twice in a row. Back to S11