S11 · Problem set 10
Problem set 10: problems that combine conversion ratios, losses, DCM, isolation, small-signal models and control, input filters, magnetics, rectifiers and inverters, resonance, heat and EMI
These problems draw on the whole course, and most chain several ideas: a duty cycle turned into a loss budget and an efficiency, a load turned into a DCM conversion ratio, a filter's resonance turned into a control limit, a converter's input resistance turned into an EMI filter's damping requirement. Work them as a review before the final.
Check
A boost from 12 V at D = 0.3, with 80 mΩ of inductor resistance, feeding 20 Ω.
(a)
Ideal output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Output with the inductor's resistance?
(c)
Efficiency?
Check
A buck from 12 V at D = 0.3, with 5 µH at 200 kHz feeding 10 Ω.
(a)
K?
(b)
Conversion ratio (it's in DCM, since K < 1 − D)?
(c)
Output voltage?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A flyback from 48 V with turns ratio n = 0.1 at D = 0.45.
(a)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Switch voltage while off (no leakage spike)?
Check
A buck's filter: 4.7 µH, 22 µF with 30 mΩ of ESR, feeding 5 Ω.
(a)
Resonance?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Q?
(c)
ESR zero?
Check
A boost at D = 0.5 feeding 5 Ω through 22 µH.
(a)
Right-half-plane zero?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Highest crossover by the one-fifth rule?
Check
A regulated converter draws 10 W from a 12 V input through an LC filter of 22 µH and 100 µF.
(a)
Magnitude of the converter's negative input resistance?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Filter's characteristic impedance?
(c)
Their ratio (it must be well below 1)?
Check
A buck's high-side MOSFET: 12 V, 5 A, 20 mΩ, D = 0.5, 5 ns rise and fall, 200 kHz, 200 pF output capacitance.
(a)
Conduction loss?
Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.
(b)
Overlap loss?
(c)
Total with the capacitive loss?
Check
A PFC rectifier with efficiency 0.97 draws from 230 V RMS to feed an 800 V bus; a three-phase inverter on that bus delivers 1000 W at 300 V line to line.
(a)
Line current RMS (unity power factor)?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
Inverter modulation index (sinusoidal PWM)?
(c)
Inverter output current per phase (unity power factor)?
Check
A series resonant converter: = 10 µH, = 22 nF, a 40 Ω load behind a bridge, run at F = 1.5.
(a)
Equivalent load?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
Switching frequency?
(c)
Gain?
Check
A MOSFET losing 0.5 W in conduction and 0.5 W in switching, with 3 K/W to 50 °C air, driven with 20 nC to 10 V at 100 kHz.
(a)
Junction temperature?
(b)
Gate-drive power?
Write units the way you normally would: 1.5 mW, 1500 µW and 0.0015 W are the same answer.
Check
A converter drawing 20 W from 48 V needs 40 dB of attenuation at 150 kHz from an LC filter with 10 µF.
(a)
Corner?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
(b)
Inductance?
(c)
Ratio of the filter's to the converter's ?
Check
A forward converter from 36 V, turns ratio 0.15, D = 0.45, 250 kHz, = 0.06 T on a 0.4 cm² core.
(a)
Output?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
(b)
Primary turns (before rounding)?
Check
Two interleaved boost phases run from 48 V at D = 0.15, each with 100 µH at 100 kHz.
(a)
What is each phase's inductor ripple?
Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.
(b)
What ripple does the total input current have?
Check
A DC-link electrolytic rated 4000 h at 105 °C sits in 45 °C air, carrying 3 A RMS through 60 mΩ of ESR with 10 K/W to the air.
(a)
How many years of continuous use should it last?
Check
A transformer's core loses 20 W and its copper 0.001/ W.
(a)
What flux density minimizes the total?
Write units the way you normally would: 1.5 T, 1500 mT and 0.0015 kT are the same answer.
(b)
What is the total loss there?
Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.
Practice
Keep practicing
15 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.