S1115 of 55
0 XP
  1. Hook
  2. Problems

S11 · Problem set 3

Problem set 3: interleaved phases and their ripple cancellation, current sharing and phase counts, switching loss across phases, bidirectional legs, battery charging and the dual active bridge

These problems build on lessons 7 to 14: the loss models and switching losses of the first problems carried into multiphase converters, the buck leg turned around to move power both ways, and battery charging. Most ask for a design number (a ripple, a phase count, a phase shift, a charging time) that a datasheet or a design review would want.

Check

Two interleaved buck phases make 1.8 V at D = 0.1, each with 2.2 µH at 600 kHz, into 100 µF.

(a)

What is each phase's inductor ripple?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What is the total output current's ripple?

(c)

What output voltage ripple results, ignoring ESR?

Check

4 interleaved buck phases make 5 V at D = 0.15, each with 1 µH at 400 kHz.

(a)

What is the total output current's ripple?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

At what frequency is that ripple?

Check

Two phases with a common duty cycle share 40 A; their current paths have 2 and 5 mΩ.

(a)

How much current does the 2 mΩ phase carry?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What conduction loss do the two paths dissipate together?

Check

A bidirectional leg links a 12 V battery to an 80 V bus through 22 µH at 200 kHz.

(a)

What duty cycle does the high-side switch run at while charging the battery?

(b)

What is the inductor's ripple?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(c)

When the battery supports the bus, what duty cycle does the low-side switch run at?

Check

A pack of 7 lithium-ion cells in series, 2.5 Ah, is charged at 1C to 4.2 V per cell by a charger of efficiency 0.95.

(a)

What is the constant-current phase's current?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

Starting empty, about how long does the constant-current phase take to reach 80%?

(c)

What input power does the charger draw at the end of that phase?

Check

A dual active bridge has 380 V on side 1 and 360 V on side 2 (referred to side 1), 60 µH of series inductance, switching at 200 kHz, with side 2 lagging by 15°.

(a)

How much power flows?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(b)

What is the most it can transfer?

Check

A dual active bridge with equal referred voltages of 400 V, 50 µH and 50 kHz must deliver 0.8 of its maximum power.

(a)

What is its maximum power?

Write units the way you normally would: 1.5 kW, 1500 W and 0.0015 MW are the same answer.

(b)

What phase shift does it need?

Check

A buck from 12 V delivers 20 A; each switching edge lasts 20 ns and the switches have 500 pF of output capacitance. Compare one phase at 500 kHz with 2 interleaved phases at 500/2 kHz each, which keeps the same output ripple frequency.

(a)

What overlap loss does the single phase have?

Write units the way you normally would: 1.5 W, 1500 mW and 0.0015 kW are the same answer.

(b)

What total overlap loss do the interleaved phases have?

(c)

What total output-capacitance loss do the interleaved phases have?

Check

2 interleaved buck phases with diodes make 1.2 V at D = 0.3, each with 2.2 µH at 300 kHz.

(a)

Below what load current do the phases enter the discontinuous mode?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

Check

A buck draws 30 A of output current at D = 0.15.

(a)

What RMS ripple current flows in its input capacitor with one phase?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

And with two interleaved phases?

Check

A synchronous buck leg makes 5 V at D = 0.25 with 4.7 µH at 500 kHz, and the load draws 0.5 A.

(a)

What is the inductor's ripple?

Write units the way you normally would: 1.5 A, 1500 mA and 0.0015 kA are the same answer.

(b)

What is the inductor current's minimum (negative means it flows back toward the input)?

Check

A battery holds up a bus at 2 kW for 5 minutes through a converter of efficiency 0.96; the battery sits at 400 V.

(a)

How much energy must the battery deliver?

Write units the way you normally would: 1.5 kWh, 1500 Wh and 0.0015 MWh are the same answer.

(b)

What current does it supply?

Have paper and a calculator ready. Work each problem out by hand, then enter the answer. Your first try on each one counts toward your score.

Practice

Keep practicing

16 kinds of problem on this topic, dealt one at a time with new numbers every time, for as long as you like.