title: "Problem set 3: interleaving and bidirectional converters"
heading: "Problem set 3: interleaved phases and their ripple cancellation, current sharing and phase counts, switching loss across phases, bidirectional legs, battery charging and the dual active bridge"
eyebrow: S11 · Problem set 3
type: problems
---

::: hook
These problems build on lessons 7 to 14: the loss models and switching losses of the first problems carried into multiphase converters, the buck leg turned around to move power both ways, and battery charging. Most ask for a design number (a ripple, a phase count, a phase shift, a charging time) that a datasheet or a design review would want.
:::

::: pool
pick: 12

::: check
kind: parts
given: V = 1.2 | 1.8 | 3.3; D = 0.1 | 0.2 | 0.3 | 0.4; L = 0.47 | 1 | 2.2; f = 300 | 600; C = 100 | 470

## Two interleaved buck phases make {V} V at D = {D}, each with {L} µH at {f} kHz, into {C} µF.

::: part
answer: V*(1 - D)/(L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is each phase's inductor ripple?

::: misses
- [any] $V(1 - D)/(Lf_s)$.
:::
:::

::: part
answer: V*(1 - 2*D)/(L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is the total output current's ripple?

::: misses
- [V*(1 - D)/(L*1e-6*f*1e3)] That's one phase's; the two partly cancel.
- [any] $(1 - 2D)/(1 - D)$ times one phase's.
:::
:::

::: part
answer: V*(1 - 2*D)/(L*1e-6*f*1e3)/(16*f*1e3*C*1e-6)*1e3
unit: mV
tolerance: 0.5%

### What output voltage ripple results, ignoring ESR?

::: misses
- [any] $\Delta I_\text{total}/(8Nf_sC)$.
:::
:::
:::

::: check
kind: parts
given: N = 3 | 4 | 6; D = 0.15 | 0.4 | 0.55 | 0.7; V = 1 | 5; L = 0.33 | 1; f = 400 | 800

## {N} interleaved buck phases make {V} V at D = {D}, each with {L} µH at {f} kHz.

::: part
answer: V/(L*1e-6*f*1e3)*N*(D - floor(N*D)/N)*((floor(N*D) + 1)/N - D)/D
unit: A
tolerance: 0.5%

### What is the total output current's ripple?

::: misses
- [V*(1 - D)/(L*1e-6*f*1e3)] That's one phase's.
- [any] The cancellation formula with $m = \lfloor ND\rfloor$.
:::
:::

::: part
answer: N*f
unit: kHz
tolerance: 0.5%

### At what frequency is that ripple?

::: misses
- [any] N times the switching frequency.
:::
:::
:::

::: check
kind: parts
given: I = 20 | 40 | 60; a = 2 | 3; b = 2.5 | 4 | 5

## Two phases with a common duty cycle share {I} A; their current paths have {a} and {b} mΩ.

::: part
answer: I*b/(a + b)
unit: A
tolerance: 0.5%

### How much current does the {a} mΩ phase carry?

::: misses
- [I*a/(a + b)] The lower resistance carries more.
- [any] Currents divide inversely with resistance.
:::
:::

::: part
answer: I^2*a*b/(a + b)*1e-3
unit: W
tolerance: 0.5%

### What conduction loss do the two paths dissipate together?

::: misses
- [any] $I_1^2R_1 + I_2^2R_2$.
:::
:::
:::

::: check
kind: parts
given: B = 60 | 80 | 100; v = 12 | 24 | 36; L = 4.7 | 10 | 22; f = 100 | 200

## A bidirectional leg links a {v} V battery to a {B} V bus through {L} µH at {f} kHz.

::: part
answer: v/B
tolerance: 0.5%

### What duty cycle does the high-side switch run at while charging the battery?

::: misses
- [any] $V_\text{low}/V_\text{high}$.
:::
:::

::: part
answer: v*(1 - v/B)/(L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is the inductor's ripple?

::: misses
- [any] $V_\text{low}(1 - D)/(Lf_s)$.
:::
:::

::: part
answer: 1 - v/B
tolerance: 0.5%

### When the battery supports the bus, what duty cycle does the low-side switch run at?

::: misses
- [v/B] That's the high-side duty; in boost mode the low-side switch is the active one.
- [any] $1 - V_\text{low}/V_\text{high}$.
:::
:::
:::

::: check
kind: parts
given: s = 4 | 7 | 13 | 14; A = 2.5 | 5 | 50; c = 0.3 | 0.5 | 1; e = 0.9 | 0.95

## A pack of {s} lithium-ion cells in series, {A} Ah, is charged at {c}C to 4.2 V per cell by a charger of efficiency {e}.

::: part
answer: c*A
unit: A
tolerance: 0.5%

### What is the constant-current phase's current?

::: misses
- [any] The C-rate times the capacity.
:::
:::

::: part
answer: 0.8/c
unit: h
tolerance: 0.5%

### Starting empty, about how long does the constant-current phase take to reach 80%?

::: misses
- [1/c] Only 80% goes in at constant current.
- [any] 0.8 of the capacity at that current.
:::
:::

::: part
answer: c*A*4.2*s/e
unit: W
tolerance: 0.5%

### What input power does the charger draw at the end of that phase?

::: misses
- [c*A*4.2*s] Divide by the efficiency.
- [any] Current × 4.2 V × cells, over efficiency.
:::
:::
:::

::: check
kind: parts
given: V = 380 | 400; U = 360 | 400 | 420; f = 50 | 100 | 200; L = 10 | 30 | 60; p = 15 | 30 | 60

## A dual active bridge has {V} V on side 1 and {U} V on side 2 (referred to side 1), {L} µH of series inductance, switching at {f} kHz, with side 2 lagging by {p}°.

::: part
answer: V*U*(p*pi/180)*(pi - p*pi/180)/(2*pi^2*f*1e3*L*1e-6)/1e3
unit: kW
tolerance: 0.5%

### How much power flows?

::: misses
- [any] $V_1V_2'\phi(\pi - \phi)/(2\pi^2f_sL)$.
:::
:::

::: part
answer: V*U/(8*f*1e3*L*1e-6)/1e3
unit: kW
tolerance: 0.5%

### What is the most it can transfer?

::: misses
- [any] $V_1V_2'/(8f_sL)$, at 90°.
:::
:::
:::

::: check
kind: parts
given: V = 400 | 800; f = 50 | 100; L = 20 | 50; q = 0.2 | 0.5 | 0.8

## A dual active bridge with equal referred voltages of {V} V, {L} µH and {f} kHz must deliver {q} of its maximum power.

::: part
answer: V^2/(8*f*1e3*L*1e-6)/1e3
unit: kW
tolerance: 0.5%

### What is its maximum power?

::: misses
- [any] $V^2/(8f_sL)$.
:::
:::

::: part
answer: 90*(1 - sqrt(1 - q))
unit: °
tolerance: 0.5%

### What phase shift does it need?

::: misses
- [90*q] Power isn't proportional to the angle.
- [any] Solve $4\phi(\pi - \phi)/\pi^2 = q$ for the smaller root.
:::
:::
:::

::: check
kind: parts
given: V = 12 | 48; I = 20 | 40 | 80; t = 10 | 20; f = 300 | 500; N = 2 | 4; C = 500 | 1500

## A buck from {V} V delivers {I} A; each switching edge lasts {t} ns and the switches have {C} pF of output capacitance. Compare one phase at {f} kHz with {N} interleaved phases at {f}/{N} kHz each, which keeps the same output ripple frequency.

::: part
answer: V*I*t*1e-9*f*1e3
unit: W
tolerance: 0.5%

### What overlap loss does the single phase have?

::: misses
- [any] $\frac12VI(t_\text{on} + t_\text{off})f_s$.
:::
:::

::: part
answer: V*I*t*1e-9*f*1e3/N
unit: W
tolerance: 0.5%

### What total overlap loss do the interleaved phases have?

::: misses
- [V*I*t*1e-9*f*1e3] Each phase switches 1/N of the current, 1/N as often.
- [any] The single phase's over N.
:::
:::

::: part
answer: 0.5*C*1e-12*V^2*f*1e3
unit: W
tolerance: 0.5%

### What total output-capacitance loss do the interleaved phases have?

::: misses
- [0.5*C*1e-12*V^2*f*1e3/N] N switches at 1/N the frequency: the capacitive loss doesn't fall.
- [any] $N \cdot \frac12C_{oss}V^2f_s/N$.
:::
:::
:::

::: check
kind: parts
given: N = 2 | 4; V = 1.2 | 5; D = 0.1 | 0.3; L = 0.47 | 2.2; f = 300 | 600

## {N} interleaved buck phases with diodes make {V} V at D = {D}, each with {L} µH at {f} kHz.

::: part
answer: N*V*(1 - D)/(2*L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### Below what load current do the phases enter the discontinuous mode?

::: misses
- [V*(1 - D)/(2*L*1e-6*f*1e3)] That's for one phase; the load splits N ways.
- [any] Each phase's share falls below half its ripple.
:::
:::
:::

::: check
kind: parts
given: I = 10 | 30 | 60; D = 0.15 | 0.25 | 0.35

## A buck draws {I} A of output current at D = {D}.

::: part
answer: I*sqrt(D*(1 - D))
unit: A
tolerance: 0.5%

### What RMS ripple current flows in its input capacitor with one phase?

::: misses
- [any] $I\sqrt{D(1 - D)}$.
:::
:::

::: part
answer: I/2*sqrt(2*D*(1 - 2*D))
unit: A
tolerance: 0.5%

### And with two interleaved phases?

::: misses
- [any] Pulses of I/2 for 2D of each period: $\frac I2\sqrt{2D(1 - 2D)}$.
:::
:::
:::

::: check
kind: parts
given: V = 3.3 | 5 | 12; D = 0.25 | 0.4; L = 1 | 4.7; f = 200 | 500; I = 0.5 | 2

## A synchronous buck leg makes {V} V at D = {D} with {L} µH at {f} kHz, and the load draws {I} A.

::: part
answer: V*(1 - D)/(L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is the inductor's ripple?

::: misses
- [any] $V(1 - D)/(Lf_s)$.
:::
:::

::: part
answer: I - V*(1 - D)/(2*L*1e-6*f*1e3)
unit: A
tolerance: 0.5%

### What is the inductor current's minimum (negative means it flows back toward the input)?

::: misses
- [any] $I - \Delta I/2$.
:::
:::
:::

::: check
kind: parts
given: P = 0.5 | 2 | 10; t = 5 | 15 | 60; v = 48 | 400; e = 0.92 | 0.96

## A battery holds up a bus at {P} kW for {t} minutes through a converter of efficiency {e}; the battery sits at {v} V.

::: part
answer: P*t/60/e
unit: kWh
tolerance: 0.5%

### How much energy must the battery deliver?

::: misses
- [P*t/60] Losses come out of the battery too.
- [any] $Pt/\eta$.
:::
:::

::: part
answer: P*1e3/(e*v)
unit: A
tolerance: 0.5%

### What current does it supply?

::: misses
- [any] $P/(\eta V_\text{bat})$.
:::
:::
:::

::: check
kind: parts
given: I = 80 | 150 | 250; p = 25 | 35; V = 0.9 | 1.2; f = 400 | 600; r = 0.3 | 0.5

## A processor rail draws {I} A at {V} V from 12 V, with phases rated {p} A each at {f} kHz, designed for an inductor ripple of {r} of each phase's share.

::: part
answer: ceil(I/p - 1e-9)
unit: phases
tolerance: 0

### How many phases does it need?

::: misses
- [any] The current over the per-phase rating, rounded up.
:::
:::

::: part
answer: V*(1 - V/12)/(r*(I/ceil(I/p - 1e-9))*f*1e3)*1e9
unit: nH
tolerance: 0.5%

### What inductance does each phase use?

::: misses
- [any] $V(1 - D)/(r I_\text{phase} f_s)$ with D = V/12.
:::
:::
:::

::: check
kind: parts
given: V = 400 | 800; b = 48 | 52 | 350; m = 0.8 | 0.85; f = 100; L = 20 | 40

## A dual active bridge links a {V} V bus to a battery of nominal {b} V, through {L} µH at {f} kHz; the turns ratio makes the nominal battery voltage, referred to the bus side, equal {V} V.

::: part
answer: V/b
tolerance: 0.5%

### What turns ratio $N_1/N_2$?

::: misses
- [any] Bus over nominal battery voltage.
:::
:::

::: part
answer: V*V*m/(8*f*1e3*L*1e-6)/1e3
unit: kW
tolerance: 0.5%

### What is its maximum power when the battery has fallen to {m} of nominal?

::: misses
- [V*V/(8*f*1e3*L*1e-6)/1e3] The referred battery voltage has fallen too.
- [any] $V_1V_2'/(8f_sL)$ with $V_2'$ reduced.
:::
:::
:::

::: check
kind: parts
given: I = 60 | 120; R = 2 | 4 | 8; z = 0.3 | 0.6 | 1.2; N = 2 | 4 | 6

## A multiphase converter carries {I} A. Each phase has {R} mΩ of conduction path and costs {z} W of fixed loss (driver, controller share, core).

::: part
answer: I^2*R*1e-3/N + N*z
unit: W
tolerance: 0.5%

### What are the total losses with {N} phases?

::: misses
- [any] $I^2R/N + Nz$.
:::
:::

::: part
answer: I*sqrt(R*1e-3/z)
unit: phases
tolerance: 0.5%

### What number of phases (before rounding) minimizes them?

::: misses
- [any] Set the derivative to zero: $N = I\sqrt{R/z}$.
:::
:::
:::

::: check
kind: parts
given: I = 0.5 | 1.5; R = 0.05 | 0.12; V = 4.1 | 4.2; Rb = 33 | 68

## A cell with $V_{oc} = 3.0 + 1.2q$ and {R} Ω charges at {I} A to 4.2 V; its balancing resistor is {Rb} Ω.

::: part
answer: (1.2 - I*R)/1.2*100
tolerance: 0.5%

### At what charge percentage does CV begin?

::: misses
- [(1.2 + I*R)/1.2*100] The IR drop reaches the limit before the cell does.
- [any] Not yet. Solve $3.0 + 1.2q + IR = 4.2$.
:::
:::

::: part
answer: V/Rb*1e3
unit: mA
tolerance: 0.5%

### What current does the balancing resistor bleed at {V} V?

::: misses
- [V*Rb] Ohm's law: $V/R$.
- [any] Not yet. $V/R$.
:::
:::

::: right
Right. Charging and balancing are both governed by resistance and a voltage limit.
:::
:::
:::