title: "Problem set 9: reliability, capacitors and solar converters"
heading: "Problem set 9: electrolytic life with ripple heating and mission profiles, failure rates, accelerated testing, ceramic derating, sharing ripple across capacitors, and photovoltaic strings, trackers and boost stages"
eyebrow: S11 · Problem set 9
type: problems
---

::: hook
These problems cover lessons 43 to 48 with the emphasis on the two newest topics: how long a converter lasts, and how a solar converter finds and holds its operating point. Several combine a thermal result from lesson 43 with a lifetime or failure-rate calculation from lesson 44, because that's how reliability is actually estimated.
:::

::: pool
pick: 12

::: check
kind: parts
given: L = 2000 | 5000 | 10000; R = 85 | 105; A = 40 | 55 | 70; I = 1 | 2.5; E = 30 | 80; t = 12 | 25

## An electrolytic rated {L} h at {R} °C sits in {A} °C air and carries {I} A RMS of ripple through {E} mΩ of ESR, with {t} K/W from core to air.

::: part
answer: A + I^2*E*1e-3*t
unit: °C
tolerance: 0.5%

### What is its core temperature?

::: misses
- [any] Ambient plus $I^2\,\text{ESR}\,R_\theta$.
:::
:::

::: part
answer: L*2^((R - A - I^2*E*1e-3*t)/10)
unit: h
tolerance: 0.5%

### What life should it have?

::: misses
- [L*2^((R - A)/10)] Include the self-heating.
- [any] $L_0 \cdot 2^{(T_0 - T)/10}$ at the core temperature.
:::
:::
:::

::: check
kind: parts
given: L = 3000 | 8000; p = 0.6 | 0.8 | 0.95; T = 40 | 50; U = 80 | 90 | 100

## An electrolytic rated {L} h at 105 °C runs at {T} °C for {p} of its life and at {U} °C for the rest.

::: part
answer: 1/(p/(L*2^((105 - T)/10)) + (1 - p)/(L*2^((105 - U)/10)))
unit: h
tolerance: 0.5%

### What life does Miner's rule give?

::: misses
- [p*L*2^((105 - T)/10) + (1 - p)*L*2^((105 - U)/10)] Wear rates add, not lives.
- [any] $1/\sum(f_i/L_i)$.
:::
:::

::: part
answer: ((1 - p)/(L*2^((105 - U)/10)))/(p/(L*2^((105 - T)/10)) + (1 - p)/(L*2^((105 - U)/10)))*100
unit: %
tolerance: 0.5%

### What percentage of the wear happens in the hot periods?

::: misses
- [any] The hot term's share of the total wear rate.
:::
:::
:::

::: check
kind: parts
given: a = 30 | 120; f = 2 | 10; b = 4 | 8; g = 40 | 100; c = 1 | 2; h = 150 | 400

## A converter has {a} small parts at {f} FIT, {b} power devices at {g} FIT and {c} electrolytics at {h} FIT.

::: part
answer: a*f + b*g + c*h
unit: FIT
tolerance: 0.5%

### What is its failure rate?

::: misses
- [any] Rates add.
:::
:::

::: part
answer: 1e9/(a*f + b*g + c*h)/8766
unit: years
tolerance: 0.5%

### What is its MTBF?

::: misses
- [any] $10^9/\text{FIT}$ hours.
:::
:::

::: part
answer: (1 - exp(-10*8766*(a*f + b*g + c*h)*1e-9))*100
unit: %
tolerance: 0.5%

### What percentage fail within ten years of continuous use?

::: misses
- [any] $1 - e^{-\lambda t}$.
:::
:::
:::

::: check
kind: parts
given: E = 0.5 | 0.7 | 0.9; a = 40 | 55; b = 105 | 125 | 150; h = 500 | 1000 | 2000

## A qualification test runs parts at {b} °C for {h} hours. The failure mechanism has an activation energy of {E} eV; in the field the parts run at {a} °C.

::: part
answer: exp(E/8.617e-5*(1/(a + 273.15) - 1/(b + 273.15)))
tolerance: 0.5%

### What is the acceleration factor?

::: misses
- [exp(E/8.617e-5*(1/a - 1/b))] Temperatures in kelvin.
- [any] $\exp[(E_a/k)(1/T_1 - 1/T_2)]$.
:::
:::

::: part
answer: h*exp(E/8.617e-5*(1/(a + 273.15) - 1/(b + 273.15)))/8766
unit: years
tolerance: 0.5%

### How many years of field use does the test represent?

::: misses
- [any] Test hours times the acceleration factor.
:::
:::
:::

::: check
kind: parts
given: C = 20 | 47 | 100; k = 0.35 | 0.5 | 0.65; t = 0.85 | 0.9; u = 10 | 22

## A rail needs {C} µF of effective capacitance. Its {u} µF X5R ceramics keep {k} of their capacitance at the working bias and {t} at the operating temperature.

::: part
answer: C/(k*t)
unit: µF
tolerance: 0.5%

### How much nominal capacitance is needed?

::: misses
- [C/k] Temperature derates it too.
- [any] Effective over the product of the factors.
:::
:::

::: part
answer: ceil(C/(k*t)/u - 1e-9)
unit: parts
tolerance: 0

### How many parts?

::: misses
- [any] Round up.
:::
:::
:::

::: check
kind: parts
given: I = 3 | 6 | 12; r = 1.2 | 2.5; E = 40 | 90

## A DC link carries {I} A RMS of ripple; its capacitors are each rated {r} A RMS at the frequency and temperature of use, with {E} mΩ of ESR.

::: part
answer: ceil(I/r - 1e-9)
unit: capacitors
tolerance: 0

### How many in parallel does the ripple rating require?

::: misses
- [any] Share the ripple, round up.
:::
:::

::: part
answer: ceil(I/r - 1e-9)*(I/ceil(I/r - 1e-9))^2*E*1e-3
unit: W
tolerance: 0.5%

### What do they dissipate in total?

::: misses
- [any] Each carries I/n through its ESR.
:::
:::
:::

::: check
kind: parts
given: v = 37 | 41 | 49; c = 0.27 | 0.3; t = 15 | 25 | 40; M = 600 | 1000 | 1500

## Modules with $V_{oc}$ = {v} V at 25 °C (rising {c}% per kelvin of cooling) go into strings for an inverter limited to {M} V; the site's coldest morning is {t} K below 25 °C.

::: part
answer: v*(1 + c/100*t)
unit: V
tolerance: 0.5%

### What is a module's coldest open-circuit voltage?

::: misses
- [any] $V_{oc}(1 + c\Delta T)$.
:::
:::

::: part
answer: floor(M/(v*(1 + c/100*t)) + 1e-9)
unit: modules
tolerance: 0

### How many modules can a string have?

::: misses
- [any] ⌊limit / cold $V_{oc}$⌋.
:::
:::
:::

::: check
kind: parts
given: m = 31 | 34 | 40; c = 0.35 | 0.4 | 0.45; t = 35 | 45; U = 200 | 350 | 550

## An inverter tracks the maximum power point only above {U} V. Its modules have $V_{mpp}$ = {m} V at 25 °C, falling {c}% per kelvin, and run {t} K hotter on summer afternoons.

::: part
answer: m*(1 - c/100*t)
unit: V
tolerance: 0.5%

### What is a module's hot $V_{mpp}$?

::: misses
- [any] $V_{mpp}(1 - c\Delta T)$.
:::
:::

::: part
answer: ceil(U/(m*(1 - c/100*t)) - 1e-9)
unit: modules
tolerance: 0

### What is the fewest modules a string can have?

::: misses
- [ceil(U/m - 1e-9)] Use the hot voltage.
- [any] ⌈minimum / hot $V_{mpp}$⌉.
:::
:::
:::

::: check
kind: parts
given: N = 10 | 16 | 22; S = 2 | 4 | 8; P = 330 | 400 | 450; c = 0.35 | 0.4; t = 20 | 35; g = 0.6 | 1

## An array of {S} strings of {N} modules, each {P} W at 25 °C and full sun, runs {t} K hotter in {g} of full sun; power falls {c}% per kelvin.

::: part
answer: S*N*P*g*(1 - c/100*t)/1e3
unit: kW
tolerance: 0.5%

### What does the array deliver?

::: misses
- [S*N*P*g/1e3] Heat costs power too.
- [any] Rated power × irradiance × temperature factor.
:::
:::
:::

::: check
kind: parts
given: n = 1 | 2 | 12; m = 30 | 36; B = 200 | 400; P = 300 | 400

## A boost stage holds {n} module(s) in series, each at {m} V and {P} W at its MPP, and feeds a {B} V bus.

::: part
answer: 1 - n*m/B
tolerance: 0.5%

### What duty cycle does it run at?

::: misses
- [any] $1 - V_\text{in}/V_\text{out}$.
:::
:::

::: part
answer: n*P/(n*m)
unit: A
tolerance: 0.5%

### What current does its inductor carry on average?

::: misses
- [any] Input power over input voltage.
:::
:::
:::

::: check
kind: parts
given: I = 4 | 7 | 9; V = 26 | 30 | 34; g = -0.08 | -0.25 | -0.6

## A tracker measures {I} A at {V} V with an incremental conductance of {g} S.

::: part
answer: I + V*g
unit: W/V
tolerance: 0.5%

### What is dP/dV?

::: misses
- [any] $I + V\,dI/dV$.
:::
:::

::: part
answer: -I/V
unit: S
tolerance: 0.5%

### What incremental conductance would mark the MPP at this operating point?

::: misses
- [I/V] At the MPP dI/dV is negative.
- [any] $dI/dV = -I/V$.
:::
:::
:::

::: check
kind: parts
given: P = 280 | 350 | 420; v = 38 | 45 | 49; i = 9 | 10.5 | 11

## A module delivers {P} W at its MPP, with $V_{oc}$ = {v} V and $I_{sc}$ = {i} A.

::: part
answer: P/(v*i)
tolerance: 0.5%

### What is its fill factor?

::: misses
- [any] $P_{mpp}/(V_{oc}I_{sc})$.
:::
:::
:::

::: check
kind: parts
given: m = 30 | 34; N = 12 | 18 | 24; d = 0.4 | 0.7

## A 60-cell module has three bypass diodes, one across each group of 20 cells; its $V_{mpp}$ is {m} V. One cell in a string of {N} such modules is shaded, so its group is bypassed through a diode dropping {d} V.

::: part
answer: N*m - m/3 - d
unit: V
tolerance: 0.5%

### What MPP voltage does the string now have (taking the unshaded groups' voltage as unchanged)?

::: misses
- [N*m - m] Only one group of the module is bypassed.
- [any] Lose a third of one module, plus the diode's drop.
:::
:::

::: part
answer: (m/3 + d)/(N*m)*100
unit: %
tolerance: 0.5%

### What percentage of the string's power is lost, at unchanged current?

::: misses
- [any] The lost voltage over the full string voltage.
:::
:::
:::

::: check
kind: parts
given: P = 4 | 10 | 25; R = 0.8 | 1.5; r = 0.4 | 0.8; A = 35 | 50; E = 0.6 | 0.8

## A device dissipates {P} W through {R} K/W (junction to sink) and a {r} K/W heat sink into {A} °C air. Its dominant failure mechanism has an activation energy of {E} eV.

::: part
answer: A + P*(R + r)
unit: °C
tolerance: 0.5%

### What is its junction temperature?

::: misses
- [any] Ambient plus power times the total thermal resistance.
:::
:::

::: part
answer: exp(E/8.617e-5*(1/(A + P*(R + r/2) + 273.15) - 1/(A + P*(R + r) + 273.15)))
tolerance: 0.5%

### How many times faster does it fail than with a heat sink of half the resistance?

::: misses
- [any] The Arrhenius factor between the two junction temperatures.
:::
:::
:::

::: check
kind: parts
given: n = 1000 | 20000 | 500000; F = 300 | 1500 | 5000; h = 8 | 12 | 16

## A product with a failure rate of {F} FIT is in service in {n} units, each running {h} hours a day.

::: part
answer: n*F*1e-9*h*365.25
unit: failures
tolerance: 0.5%

### How many field failures should the fleet see per year?

::: misses
- [n*F*1e-9*8766] The units don't run around the clock.
- [any] Units × rate × operating hours.
:::
:::

::: part
answer: (1 - exp(-F*1e-9*h*365.25*10))*100
unit: %
tolerance: 0.5%

### What percentage of the units fail randomly over a ten-year service life?

::: misses
- [any] $1 - e^{-\lambda t}$ with t the operating hours.
:::
:::
:::
:::