S11 · Lesson 40 · Resonant converters
Driving a resonant tank with a square wave and keeping only the fundamental, the series resonant converter's voltage gain against switching frequency and load, the equivalent load of a rectifier, why running above resonance gives zero-voltage switching, and the LLC converter
Most high-efficiency server and laptop power supplies use an LLC resonant converter for their isolated stage. A bridge drives a series L–C tank with a square wave, and the tank, tuned near the switching frequency, filters the square wave into a nearly sinusoidal current. The output is controlled by moving the switching frequency along the tank's resonance curve rather than by duty cycle. The payoff is soft switching: the transistors turn on at zero voltage, removing most of the switching loss of lesson 8.
- The voltage gain of a series resonant converter against normalized switching frequency , for a tank quality factor Q set by the load.
- At F = 1 the tank is transparent and the gain is 1 at any load. Away from resonance the tank's impedance drops part of the voltage; heavier loads (higher Q) make the curve sharper.
- Running above resonance (F > 1) makes the tank inductive, which is what allows zero-voltage switching.
Predict
A series resonant converter has = 20 µH and = 50 nF, feeding a 50 Ω load through a bridge rectifier with a capacitive filter. What's its gain at 1.5 times the resonant frequency?
= 159 kHz, = 20 Ω, and the rectifier looks like = 40.5 Ω, so Q = 0.49. At F = 1.5, = 0.925. Light load (low Q) makes the gain hard to control: large frequency changes move it little.
Name it
The sinusoidal approximation
The bridge's square wave of amplitude V has a fundamental of peak . A high-Q tank passes mostly that fundamental, so the tank current is nearly sinusoidal. A rectifier with a capacitive output filter fed by a sinusoidal current looks to the tank like a resistance
The series resonant converter
With , , and , the fundamental voltage divides between the tank and :
(times any turns ratio). The gain is at most 1 at resonance, so the SRC only steps down, and at light load it loses control.
Soft switching
Above resonance the tank's current lags the bridge voltage. When a switch turns off, the lagging current discharges the opposite switch's output capacitance and forward-biases its body diode before that switch turns on: zero-voltage switching, removing the turn-on loss and the loss.
LLC
Adding a parallel magnetizing inductance (usually the transformer's own) gives a second, lower resonance with . Between the two, the gain can exceed 1, and at the series resonance the gain is unity independent of load, so the converter can sit there at nominal input with high efficiency and still regulate over a range.
Worked example
Find the SRC's characteristics for = 20 µH, = 50 nF and R = 50 Ω.
Show the solution
- The tank.
- Load and Q.
- Gains. 0.984 at F = 1.2, 0.925 at 1.5 and 0.804 at 2.
- For a gain of 0.8. The converter must run at F = 2.02, 321 kHz: a wide frequency range for a modest change in gain.
Answer = 159.2 kHz, = 20 Ω, = 40.5 Ω and Q = 0.493; a gain of 0.8 needs 321 kHz.
Worked example
Why does an LLC converter use the transformer's magnetizing inductance on purpose?
Show the solution
- In a forward converter. Magnetizing current is a nuisance.
- In an LLC. It provides the lagging current that discharges the switches' capacitances during the dead time, even at no load, so zero-voltage switching holds across the whole load range.
- The gain peak. It also creates the gain peak above 1 that lets the converter boost slightly when the input sags.
Answer the magnetizing current gives zero-voltage switching at every load, and the magnetizing inductance creates a gain peak above 1 for when the input sags.
Worked example
A series resonant converter feeds a 20 Ω load through a bridge rectifier with a capacitive filter. Design a tank resonating at 200 kHz with Q = 1.
Show the solution
- Equivalent load. The rectifier presents to the tank's sinusoidal current
- Characteristic impedance. Q = 1 means
- Inductor and capacitor.
- Choosing Q. A higher Q would narrow the frequency range needed to regulate but raise the tank's circulating voltages.
Answer = 12.9 µH and = 49.1 nF.
Check
A resonant tank has = 20 µH and = 10 nF. What's its resonant frequency?
Write units the way you normally would: 1.5 kHz, 1500 Hz and 0.0015 MHz are the same answer.
Check
A bridge rectifier with a capacitive filter feeds 50 Ω. What resistance does it present to a sinusoidal tank current?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
Check
A series resonant converter has = 10 µH, = 22 nF and an 80 Ω load. What's its Q?
Check
A series resonant converter with Q = 1 runs at F = 0.7. What's its voltage gain?
Check
A series resonant converter with Q = 1 needs a gain of 0.6. What normalized frequency above resonance does it run at?
Check
A half-bridge drives a tank at resonance from a 200 V bus through a transformer of ratio 0.05. What's the peak of the fundamental the secondary sees?
Write units the way you normally would: 1.5 V, 1500 mV and 0.0015 kV are the same answer.
Check
A series resonant converter feeds 20 Ω through a capacitively filtered bridge rectifier. Its tank must resonate at 500 kHz with Q = 0.5.
(a)
What resistance does the rectifier present to the tank?
Write units the way you normally would: 1.5 Ω, 1500 mΩ and 0.0015 kΩ are the same answer.
(b)
What ?
(c)
What ?
Check
A series resonant converter with quality factor Q runs at normalized frequency F; its rectifier feeds R.
Step 1
What is its voltage gain?
Type it the way you would write it, like 3sin(2πft) or 3*sin(2*pi*f*t). Angles can be in radians or carry a degree sign, like 45°.
Step 2
What equivalent resistance does the tank see?
Explain why
Why does operating a resonant converter above its resonant frequency give zero-voltage switching?
Above resonance the series tank's inductive reactance exceeds its capacitive reactance, so the tank current lags the square-wave voltage applied by the bridge. When the bridge switches, the current is still flowing in the direction set by the previous half cycle. During the dead time, with both switches off, that current has nowhere to go but through the switches' output capacitances, charging one and discharging the other until the switch about to turn on has zero voltage across it and its body diode conducts. Turning it on then wastes no capacitive energy and has no voltage–current overlap. Below resonance the current leads, it reverses before the switching instant, and the switches turn on hard.
Practice
Keep practicing