---
title: Resonant converters
heading: Driving a resonant tank with a square wave and keeping only the fundamental, the series resonant converter's voltage gain against switching frequency and load, the equivalent load of a rectifier, why running above resonance gives zero-voltage switching, and the LLC converter
eyebrow: S11 · Lesson 40 · Resonant converters
xp: 50
---

::: hook
Most high-efficiency server and laptop power supplies use an LLC resonant converter for their isolated stage. A bridge drives a series L–C tank with a square wave, and the tank, tuned near the switching frequency, filters the square wave into a nearly sinusoidal current. The output is controlled by moving the switching frequency along the tank's resonance curve rather than by duty cycle. The payoff is soft switching: the transistors turn on at zero voltage, removing most of the switching loss of lesson 8.
:::

::: play
- The voltage gain of a series resonant converter against normalized switching frequency $F = f_s/f_0$, for a tank quality factor Q set by the load.
- At F = 1 the tank is transparent and the gain is 1 at any load. Away from resonance the tank's impedance drops part of the voltage; heavier loads (higher Q) make the curve sharper.
- Running above resonance (F > 1) makes the tank inductive, which is what allows zero-voltage switching.
:::

```sim plot
view: graph
x: F = 0.5..3 log
y: M = 0..1.05
slider: Q = 0.2..5 = 0.49 log
plot: 1/sqrt(1 + Q^2*(F - 1/F)^2) | samples: 500 | label: gain
marker: x = 1 | label: resonance
readout: gain at F of 1.5 = 1/sqrt(1 + Q^2*(1.5 - 1/1.5)^2) | digits: 3
```

::: predict
## A series resonant converter has $L_r$ = 20 µH and $C_r$ = 50 nF, feeding a 50 Ω load through a bridge rectifier with a capacitive filter. What's its gain at 1.5 times the resonant frequency?

- [ ] 0.5
- [ ] 0.67
- [x] About 0.92
- [ ] 1.5

::: reveal
$f_0$ = 159 kHz, $R_0 = \sqrt{L_r/C_r}$ = 20 Ω, and the rectifier looks like $R_e = 8R/\pi^2$ = 40.5 Ω, so Q = 0.49. At F = 1.5, $M = 1/\sqrt{1 + 0.49^2(1.5 - 0.667)^2}$ = 0.925. Light load (low Q) makes the gain hard to control: large frequency changes move it little.
:::
:::

::: nameit
## The sinusoidal approximation

The bridge's square wave of amplitude V has a fundamental of peak $\frac{4}{\pi}V$. A high-Q tank passes mostly that fundamental, so the tank current is nearly sinusoidal. A rectifier with a capacitive output filter fed by a sinusoidal current looks to the tank like a resistance

$$R_e = \frac{8}{\pi^2}R$$

## The series resonant converter

With $f_0 = 1/2\pi\sqrt{L_rC_r}$, $R_0 = \sqrt{L_r/C_r}$, $Q = R_0/R_e$ and $F = f_s/f_0$, the fundamental voltage divides between the tank and $R_e$:

$$M = \frac{1}{\sqrt{1 + Q^2\left(F - \frac{1}{F}\right)^2}}$$

(times any turns ratio). The gain is at most 1 at resonance, so the SRC only steps down, and at light load it loses control.

## Soft switching

Above resonance the tank's current lags the bridge voltage. When a switch turns off, the lagging current discharges the opposite switch's output capacitance and forward-biases its body diode before that switch turns on: **zero-voltage switching**, removing the turn-on loss and the $\frac{1}{2}C_{oss}V^2$ loss.

## LLC

Adding a parallel magnetizing inductance $L_m$ (usually the transformer's own) gives a second, lower resonance with $L_r + L_m$. Between the two, the gain can exceed 1, and at the series resonance the gain is unity independent of load, so the converter can sit there at nominal input with high efficiency and still regulate over a range.
:::

::: example
## Find the SRC's characteristics for $L_r$ = 20 µH, $C_r$ = 50 nF and R = 50 Ω.

::: solution
1. **The tank.**
   $$\begin{aligned} f_0 &= \frac{1}{2\pi\sqrt{L_rC_r}} \\ &= 159.2\ \text{kHz} \\ R_0 &= \sqrt{L_r/C_r} \\ &= 20\ \Omega \end{aligned}$$
2. **Load and Q.**
   $$\begin{aligned} R_e &= 8R/\pi^2 \\ &= 40.5\ \Omega \\ Q &= R_0/R_e \\ &= 0.493 \end{aligned}$$
3. **Gains.** 0.984 at F = 1.2, 0.925 at 1.5 and 0.804 at 2.
4. **For a gain of 0.8.** The converter must run at F = 2.02, 321 kHz: a wide frequency range for a modest change in gain.

**Answer:** $f_0$ = 159.2 kHz, $R_0$ = 20 Ω, $R_e$ = 40.5 Ω and Q = 0.493; a gain of 0.8 needs 321 kHz.
:::
:::

::: example
## Why does an LLC converter use the transformer's magnetizing inductance on purpose?

::: solution
1. **In a forward converter.** Magnetizing current is a nuisance.
2. **In an LLC.** It provides the lagging current that discharges the switches' capacitances during the dead time, even at no load, so zero-voltage switching holds across the whole load range.
3. **The gain peak.** It also creates the gain peak above 1 that lets the converter boost slightly when the input sags.

**Answer:** the magnetizing current gives zero-voltage switching at every load, and the magnetizing inductance creates a gain peak above 1 for when the input sags.
:::
:::

::: example
## A series resonant converter feeds a 20 Ω load through a bridge rectifier with a capacitive filter. Design a tank resonating at 200 kHz with Q = 1.

::: solution
1. **Equivalent load.** The rectifier presents to the tank's sinusoidal current
   $$\begin{aligned} R_e &= 8R/\pi^2 \\ &= 16.2\ \Omega \end{aligned}$$
2. **Characteristic impedance.** Q = 1 means
   $$\begin{aligned} R_0 &= \sqrt{L_r/C_r} \\ &= 16.2\ \Omega \end{aligned}$$
3. **Inductor and capacitor.**
   $$\begin{aligned} L_r &= \frac{R_0}{2\pi f_0} \\ &= 12.9\ \mu\text{H} \\ C_r &= \frac{1}{2\pi f_0R_0} \\ &= 49.1\ \text{nF} \end{aligned}$$
4. **Choosing Q.** A higher Q would narrow the frequency range needed to regulate but raise the tank's circulating voltages.

**Answer:** $L_r$ = 12.9 µH and $C_r$ = 49.1 nF.
:::
:::

::: check
given: L = 5 | 20 | 100; C = 10 | 47 | 220
answer: 1/(2*pi*sqrt(L*1e-6*C*1e-9))/1000
unit: kHz
tolerance: 0.5%

## A resonant tank has $L_r$ = {L} µH and $C_r$ = {C} nF. What's its resonant frequency?

::: right
Right. $1/2\pi\sqrt{L_rC_r}$ = {answer} kHz.
:::

::: misses
- [any] Not yet. $f_0 = 1/2\pi\sqrt{LC}$.
:::
:::

::: check
given: R = 10 | 50 | 200
answer: 8*R/pi^2
unit: Ω
tolerance: 0.5%

## A bridge rectifier with a capacitive filter feeds {R} Ω. What resistance does it present to a sinusoidal tank current?

::: right
Right. $8R/\pi^2$ = {answer} Ω.
:::

::: misses
- [R] The rectifier's square-wave voltage and sinusoidal current change the effective value: $8/\pi^2$.
- [any] Not yet. Fundamental of the rectifier's input voltage over its current.
:::
:::

::: check
given: L = 10 | 40; C = 22 | 100; R = 20 | 80
answer: sqrt(L*1e-6/(C*1e-9))/(8*R/pi^2)
tolerance: 0.5%

## A series resonant converter has $L_r$ = {L} µH, $C_r$ = {C} nF and a {R} Ω load. What's its Q?

::: right
Right. $R_0/R_e$ with $R_0 = \sqrt{L_r/C_r}$ and $R_e = 8R/\pi^2$: {answer}.
:::

::: misses
- [sqrt(L*1e-6/(C*1e-9))/R] Use the rectifier's equivalent resistance $8R/\pi^2$.
- [any] Not yet. $Q = R_0/R_e$.
:::
:::

::: check
given: Q = 0.3 | 1 | 3; F = 0.7 | 1.3 | 2
answer: 1/sqrt(1 + Q^2*(F - 1/F)^2)
tolerance: 0.5%

## A series resonant converter with Q = {Q} runs at F = {F}. What's its voltage gain?

::: right
Right. $1/\sqrt{1 + Q^2(F - 1/F)^2}$ = {answer}.
:::

::: misses
- [any] Not yet. The tank divides the fundamental with $R_e$.
:::
:::

::: check
given: Q = 0.5 | 1 | 2; M = 0.6 | 0.8 | 0.9
answer: (sqrt(1/M^2 - 1)/Q + sqrt((sqrt(1/M^2 - 1)/Q)^2 + 4))/2
tolerance: 0.5%

## A series resonant converter with Q = {Q} needs a gain of {M}. What normalized frequency above resonance does it run at?

::: right
Right. $F - 1/F = \sqrt{1/M^2 - 1}/Q$, so F = {answer}.
:::

::: misses
- [any] Not yet. Solve the gain formula for F > 1.
:::
:::

::: check
given: V = 200 | 400; n = 0.05 | 0.1
answer: 4/pi*V/2*n
unit: V
tolerance: 0.5%

## A half-bridge drives a tank at resonance from a {V} V bus through a transformer of ratio {n}. What's the peak of the fundamental the secondary sees?

::: right
Right. The half-bridge swings ±V/2, whose fundamental peak is $\frac{4}{\pi}\cdot\frac{V}{2}$, times n: {answer} V.
:::

::: misses
- [4/pi*V*n] A half-bridge's square wave has amplitude V/2.
- [any] Not yet. Fundamental of a square wave, then the turns ratio.
:::
:::

::: check
kind: parts
given: R = 5 | 20 | 50; Q = 0.5 | 1 | 2; f = 100 | 200 | 500

## A series resonant converter feeds {R} Ω through a capacitively filtered bridge rectifier. Its tank must resonate at {f} kHz with Q = {Q}.

::: part
answer: 8*R/pi^2
unit: Ω
tolerance: 0.5%

### What resistance does the rectifier present to the tank?

::: misses
- [any] $8R/\pi^2$.
:::
:::

::: part
answer: Q*8*R/pi^2/(2*pi*f*1e3)*1e6
unit: µH
tolerance: 0.5%

### What $L_r$?

::: misses
- [any] $R_0 = QR_e$ and $L_r = R_0/\omega_0$.
:::
:::

::: part
answer: 1/(2*pi*f*1e3*Q*8*R/pi^2)*1e9
unit: nF
tolerance: 0.5%

### What $C_r$?

::: misses
- [any] $C_r = 1/(\omega_0R_0)$.
:::
:::
:::

::: check
kind: derivation
vars: Q = 0.2..5, F = 0.5..3, R = 1..100

## A series resonant converter with quality factor Q runs at normalized frequency F; its rectifier feeds R.

::: step
answer: 1/sqrt(1 + Q^2*(F - 1/F)^2)

### What is its voltage gain?
:::

::: step
answer: 8*R/pi^2

### What equivalent resistance does the tank see?
:::

::: right
Right. At F = 1 the gain is 1 whatever Q; away from resonance, high Q drops it fast.
:::
:::

::: explain
## Why does operating a resonant converter above its resonant frequency give zero-voltage switching?

::: model
Above resonance the series tank's inductive reactance exceeds its capacitive reactance, so the tank current lags the square-wave voltage applied by the bridge. When the bridge switches, the current is still flowing in the direction set by the previous half cycle. During the dead time, with both switches off, that current has nowhere to go but through the switches' output capacitances, charging one and discharging the other until the switch about to turn on has zero voltage across it and its body diode conducts. Turning it on then wastes no capacitive energy and has no voltage–current overlap. Below resonance the current leads, it reverses before the switching instant, and the switches turn on hard.
:::
:::

::: practice

::: check
given: L = 8 | 60; C = 15 | 150
answer: 1/(2*pi*sqrt(L*1e-6*C*1e-9))/1000
unit: kHz
tolerance: 0.5%

## Resonant frequency: {L} µH, {C} nF?

::: misses
- [any] $1/2\pi\sqrt{LC}$.
:::
:::

::: check
given: Q = 0.4 | 2.5; F = 1.1 | 1.8
answer: 1/sqrt(1 + Q^2*(F - 1/F)^2)
tolerance: 0.5%

## SRC gain: Q = {Q}, F = {F}?

::: misses
- [any] $1/\sqrt{1 + Q^2(F - 1/F)^2}$.
:::
:::

::: check
given: R = 5 | 10 | 24 | 50 | 120 | 200
answer: 8*R/pi^2
unit: Ω
tolerance: 0.5%

## Rectifier's equivalent resistance for {R} Ω?

::: misses
- [any] $8R/\pi^2$.
:::
:::
:::
